Dosimetric characteristics of fabricated Ge-doped silica optical fibre for small-field dosimetry

We study 3 mm long germanium-doped (Ge-doped) silica fibres for small-field dosimetry, seeking to overcome spatial resolution and charged-particle disequilibrium issues, also any associated dose deviation from that of computerised treatment plan dose delivery. Investigation has been made of the ther...

Full description

Bibliographic Details
Main Authors: S.E. Lam, D.A. Bradley, R. Mahmud, M. Pawanchek, H.A. Abdul Rashid, N. Mohd Noor
Format: Article
Language:English
Published: Elsevier 2019-03-01
Series:Results in Physics
Online Access:http://www.sciencedirect.com/science/article/pii/S2211379718325257