IN-SITU MEASURING METHOD OF RADON AND THORON DIFFUSION COEFFICIENT IN SOIL

A simple and valid in-situ measurement method of effective diffusion coefficient of radon and thoron in soil and other porous materials was designed. The analysis of numerical investigation of radon and thoron transport in upper layers of soil revealed that thoron flux density from the earth surface...

Full description

Bibliographic Details
Main Author: V.S. Yakovleva
Format: Article
Language:English
Published: KamGU by Vitus Bering 2014-06-01
Series:Vestnik KRAUNC: Fiziko-Matematičeskie Nauki
Subjects:
Online Access:http://krasec.ru/wp-content/uploads/2016/07/Yakovleva2014-1.pdf
Description
Summary:A simple and valid in-situ measurement method of effective diffusion coefficient of radon and thoron in soil and other porous materials was designed. The analysis of numerical investigation of radon and thoron transport in upper layers of soil revealed that thoron flux density from the earth surface does not depend on soil gas advective velocity and varies only with diffusion coefficient changes. This result showed the advantages of thoron using versus radon using in the suggested method. The comparison of the new method with existing ones previously developed. The method could be helpful for solving of problems of radon mass-transport in porous media and gaseous exchange between soil and atmosphere.
ISSN:2079-6641
2079-665X