Relationship between central corneal thickness, intra ocular pressure and visual field in normal tension and primary open angle glaucoma

Background and Objective: Glaucoma is one of the most important cause of blindness wordwide. Exact determination of intra ocular pressure is important for the diagnosis and decision making about glaucoma treatment. Central corneal thickness is considered as effective factor on intra ocular pressure...

Full description

Bibliographic Details
Main Authors: Mahjoob M (MSc), Validam MH (MD), Azimi Khorasani A (PhD), Shahrakipoor M (PhD), Momeni Moghadam H (MSc), Nejati J (MSc), Tavakoli A (BSc), Moradgholi M (BSc), Kamali P (BSc), Sargazi M (BSc)
Format: Article
Language:fas
Published: Golestan University of Medical Sciences 2012-05-01
Series:مجله دانشگاه علوم پزشکی گرگان
Subjects:
Online Access:http://goums.ac.ir/journal/browse.php?a_code=A-10-1-585&slc_lang=en&sid=1
id doaj-9b1d149c36bf413c9fee82c3fa26a5d7
record_format Article
spelling doaj-9b1d149c36bf413c9fee82c3fa26a5d72020-11-24T21:42:57ZfasGolestan University of Medical Sciences مجله دانشگاه علوم پزشکی گرگان1562-47652008-40802012-05-011427075Relationship between central corneal thickness, intra ocular pressure and visual field in normal tension and primary open angle glaucomaMahjoob M (MSc)0Validam MH (MD)1Azimi Khorasani A (PhD)2Shahrakipoor M (PhD)3Momeni Moghadam H (MSc)4Nejati J (MSc)5Tavakoli A (BSc)6Moradgholi M (BSc)7Kamali P (BSc)8Sargazi M (BSc)9 Academic Instructor, Department of Optometry, Zahedan University of Medical Sciences, Zahedan, Iran Assistant Professor, Department of Ophthalmology, Zahedan University of Medical Sciences, Zahedan, Iran Associate Professor, Department of Optometry, Mashhad University of Medical Sciences, Mashhad, Iran Assistant Professor, Department of Health, Faculty of Medicine, Zahedan University of Medical Sciences, Zahedan, Iran Academic Instructor, Department of Optometry, Zahedan University of Medical Sciences, Zahedan, Iran MSc in Health, Health Center of Sistan and Baluchestan, Zahedan, Iran BSc in Optometry BSc in Optometry BSc in Optometry BSc in Optometry, Azahra Hospital, Zahedan, Iran Background and Objective: Glaucoma is one of the most important cause of blindness wordwide. Exact determination of intra ocular pressure is important for the diagnosis and decision making about glaucoma treatment. Central corneal thickness is considered as effective factor on intra ocular pressure and visual field defect. This study was carried out to determine the relationship between central corneal thickness, intra ocular pressure and visual field in normal tension and primary open angle glaucoma. Materials and Methods: This descriptive study was carried out on 45 eyes with normal tension glaucoma and 45 eyes with primary open angle glaucoma in Al-Zahra ophthalmology hospital in Zahedan, Iran during 2010. Intra ocular pressure and central corneal thickness were measured by Goldman tonometer and pachymeter and visual field exanimated by Humphrey perimeter. Data were analyzed using SPSS-16, paired t-test, ANOVA, Mann–Whitney and Pearson corlateion tests. Results: There was significant correlation between central corneal thickness and intra ocular pressure (r=0.309, P<0.05). A significant difference was detected in intra ocular pressure between two type of glaucoma (P<0.05). Mean value of central corneal thickness in patient with mild visual field defect was higher than severe visual field defect but there was not significant statistical difference between central corneal thickness and visual field defect in subjects with glaucoma. Conclusion: This study indicated that increasing corneal thickness is accompanied with intra occular presure.http://goums.ac.ir/journal/browse.php?a_code=A-10-1-585&slc_lang=en&sid=1Central corneal thicknessIntra ocular pressureVisual field defectGlaucoma
collection DOAJ
language fas
format Article
sources DOAJ
author Mahjoob M (MSc)
Validam MH (MD)
Azimi Khorasani A (PhD)
Shahrakipoor M (PhD)
Momeni Moghadam H (MSc)
Nejati J (MSc)
Tavakoli A (BSc)
Moradgholi M (BSc)
Kamali P (BSc)
Sargazi M (BSc)
spellingShingle Mahjoob M (MSc)
Validam MH (MD)
Azimi Khorasani A (PhD)
Shahrakipoor M (PhD)
Momeni Moghadam H (MSc)
Nejati J (MSc)
Tavakoli A (BSc)
Moradgholi M (BSc)
Kamali P (BSc)
Sargazi M (BSc)
Relationship between central corneal thickness, intra ocular pressure and visual field in normal tension and primary open angle glaucoma
مجله دانشگاه علوم پزشکی گرگان
Central corneal thickness
Intra ocular pressure
Visual field defect
Glaucoma
author_facet Mahjoob M (MSc)
Validam MH (MD)
Azimi Khorasani A (PhD)
Shahrakipoor M (PhD)
Momeni Moghadam H (MSc)
Nejati J (MSc)
Tavakoli A (BSc)
Moradgholi M (BSc)
Kamali P (BSc)
Sargazi M (BSc)
author_sort Mahjoob M (MSc)
title Relationship between central corneal thickness, intra ocular pressure and visual field in normal tension and primary open angle glaucoma
title_short Relationship between central corneal thickness, intra ocular pressure and visual field in normal tension and primary open angle glaucoma
title_full Relationship between central corneal thickness, intra ocular pressure and visual field in normal tension and primary open angle glaucoma
title_fullStr Relationship between central corneal thickness, intra ocular pressure and visual field in normal tension and primary open angle glaucoma
title_full_unstemmed Relationship between central corneal thickness, intra ocular pressure and visual field in normal tension and primary open angle glaucoma
title_sort relationship between central corneal thickness, intra ocular pressure and visual field in normal tension and primary open angle glaucoma
publisher Golestan University of Medical Sciences
series مجله دانشگاه علوم پزشکی گرگان
issn 1562-4765
2008-4080
publishDate 2012-05-01
description Background and Objective: Glaucoma is one of the most important cause of blindness wordwide. Exact determination of intra ocular pressure is important for the diagnosis and decision making about glaucoma treatment. Central corneal thickness is considered as effective factor on intra ocular pressure and visual field defect. This study was carried out to determine the relationship between central corneal thickness, intra ocular pressure and visual field in normal tension and primary open angle glaucoma. Materials and Methods: This descriptive study was carried out on 45 eyes with normal tension glaucoma and 45 eyes with primary open angle glaucoma in Al-Zahra ophthalmology hospital in Zahedan, Iran during 2010. Intra ocular pressure and central corneal thickness were measured by Goldman tonometer and pachymeter and visual field exanimated by Humphrey perimeter. Data were analyzed using SPSS-16, paired t-test, ANOVA, Mann–Whitney and Pearson corlateion tests. Results: There was significant correlation between central corneal thickness and intra ocular pressure (r=0.309, P<0.05). A significant difference was detected in intra ocular pressure between two type of glaucoma (P<0.05). Mean value of central corneal thickness in patient with mild visual field defect was higher than severe visual field defect but there was not significant statistical difference between central corneal thickness and visual field defect in subjects with glaucoma. Conclusion: This study indicated that increasing corneal thickness is accompanied with intra occular presure.
topic Central corneal thickness
Intra ocular pressure
Visual field defect
Glaucoma
url http://goums.ac.ir/journal/browse.php?a_code=A-10-1-585&slc_lang=en&sid=1
work_keys_str_mv AT mahjoobmmsc relationshipbetweencentralcornealthicknessintraocularpressureandvisualfieldinnormaltensionandprimaryopenangleglaucoma
AT validammhmd relationshipbetweencentralcornealthicknessintraocularpressureandvisualfieldinnormaltensionandprimaryopenangleglaucoma
AT azimikhorasaniaphd relationshipbetweencentralcornealthicknessintraocularpressureandvisualfieldinnormaltensionandprimaryopenangleglaucoma
AT shahrakipoormphd relationshipbetweencentralcornealthicknessintraocularpressureandvisualfieldinnormaltensionandprimaryopenangleglaucoma
AT momenimoghadamhmsc relationshipbetweencentralcornealthicknessintraocularpressureandvisualfieldinnormaltensionandprimaryopenangleglaucoma
AT nejatijmsc relationshipbetweencentralcornealthicknessintraocularpressureandvisualfieldinnormaltensionandprimaryopenangleglaucoma
AT tavakoliabsc relationshipbetweencentralcornealthicknessintraocularpressureandvisualfieldinnormaltensionandprimaryopenangleglaucoma
AT moradgholimbsc relationshipbetweencentralcornealthicknessintraocularpressureandvisualfieldinnormaltensionandprimaryopenangleglaucoma
AT kamalipbsc relationshipbetweencentralcornealthicknessintraocularpressureandvisualfieldinnormaltensionandprimaryopenangleglaucoma
AT sargazimbsc relationshipbetweencentralcornealthicknessintraocularpressureandvisualfieldinnormaltensionandprimaryopenangleglaucoma
_version_ 1725916099144318976