Impact of the Confinement Plate on the Velocity of Synthetic Jet

In the paper, the impact of the limitation of the environment around the office of synthetic jet actuators were tested. One short and three length orifices were tested and compared with and without confinement plate. In total, seven different synthetic jet actuators were investigated. The constant t...

Full description

Bibliographic Details
Main Authors: Emil Smyk, Robert Smusz
Format: Article
Language:English
Published: MDPI AG 2021-08-01
Series:Actuators
Subjects:
Online Access:https://www.mdpi.com/2076-0825/10/9/208
id doaj-9ba696cf90bd4e3e8d6f6390132ce03e
record_format Article
spelling doaj-9ba696cf90bd4e3e8d6f6390132ce03e2021-09-25T23:32:44ZengMDPI AGActuators2076-08252021-08-011020820810.3390/act10090208Impact of the Confinement Plate on the Velocity of Synthetic JetEmil Smyk0Robert Smusz1Faculty of Mechanical Engineering, Bydgoszcz University of Science and Technology, 85-796 Bydgoszcz, PolandDepartment of Mechanical Engineering, Rzeszow University of Technology, 35-959 Rzeszow, PolandIn the paper, the impact of the limitation of the environment around the office of synthetic jet actuators were tested. One short and three length orifices were tested and compared with and without confinement plate. In total, seven different synthetic jet actuators were investigated. The constant temperature anemometer was used for the velocity measurements. The synthetic jet was tested for the Reynolds number in the range of 2300 < <i>Re</i> < 19,500, and the Stokes number in the range of 46 < <i>S</i> < 62. The confinement plate decreased the velocity of synthetic jet depending on the actuator supply power even around 5%. However, the differences in axial velocity profile are slight and the impact of the confinement plate was visible only in the distance <i>x</i>/<i>d</i> < 4.https://www.mdpi.com/2076-0825/10/9/208synthetic jetconfinement plateZNMFefficiency
collection DOAJ
language English
format Article
sources DOAJ
author Emil Smyk
Robert Smusz
spellingShingle Emil Smyk
Robert Smusz
Impact of the Confinement Plate on the Velocity of Synthetic Jet
Actuators
synthetic jet
confinement plate
ZNMF
efficiency
author_facet Emil Smyk
Robert Smusz
author_sort Emil Smyk
title Impact of the Confinement Plate on the Velocity of Synthetic Jet
title_short Impact of the Confinement Plate on the Velocity of Synthetic Jet
title_full Impact of the Confinement Plate on the Velocity of Synthetic Jet
title_fullStr Impact of the Confinement Plate on the Velocity of Synthetic Jet
title_full_unstemmed Impact of the Confinement Plate on the Velocity of Synthetic Jet
title_sort impact of the confinement plate on the velocity of synthetic jet
publisher MDPI AG
series Actuators
issn 2076-0825
publishDate 2021-08-01
description In the paper, the impact of the limitation of the environment around the office of synthetic jet actuators were tested. One short and three length orifices were tested and compared with and without confinement plate. In total, seven different synthetic jet actuators were investigated. The constant temperature anemometer was used for the velocity measurements. The synthetic jet was tested for the Reynolds number in the range of 2300 < <i>Re</i> < 19,500, and the Stokes number in the range of 46 < <i>S</i> < 62. The confinement plate decreased the velocity of synthetic jet depending on the actuator supply power even around 5%. However, the differences in axial velocity profile are slight and the impact of the confinement plate was visible only in the distance <i>x</i>/<i>d</i> < 4.
topic synthetic jet
confinement plate
ZNMF
efficiency
url https://www.mdpi.com/2076-0825/10/9/208
work_keys_str_mv AT emilsmyk impactoftheconfinementplateonthevelocityofsyntheticjet
AT robertsmusz impactoftheconfinementplateonthevelocityofsyntheticjet