Investigação do fluxo expiratório máximo em gestantes saudáveis Peak expiratory flow analysis in healthy pregnant women

OBJETIVO: investigar os valores normais de fluxo expiratório máximo para gestantes normais, com uso de aparelho expiratório portátil (Mini-Wright Peak Flow Meter), relacionando as medidas obtidas com estatura, índice de massa corporal (IMC) e idade de cada paciente, ao longo da gestação. MÉTODOS: es...

Full description

Bibliographic Details
Main Authors: Gustavo Antonio Neppelenbroek, Francisco Mauad-Filho, Sérgio Pereira da Cunha, Geraldo Duarte, Antonio Gadelha Costa, Patrícia Spara, Glauce Maria Gelonezi
Format: Article
Language:English
Published: Federação Brasileira das Sociedades de Ginecologia e Obstetrícia 2005-01-01
Series:Revista Brasileira de Ginecologia e Obstetrícia
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-72032005000100008
id doaj-9be9066ecebb46dba85d07bd05405582
record_format Article
collection DOAJ
language English
format Article
sources DOAJ
author Gustavo Antonio Neppelenbroek
Francisco Mauad-Filho
Sérgio Pereira da Cunha
Geraldo Duarte
Antonio Gadelha Costa
Patrícia Spara
Glauce Maria Gelonezi
spellingShingle Gustavo Antonio Neppelenbroek
Francisco Mauad-Filho
Sérgio Pereira da Cunha
Geraldo Duarte
Antonio Gadelha Costa
Patrícia Spara
Glauce Maria Gelonezi
Investigação do fluxo expiratório máximo em gestantes saudáveis Peak expiratory flow analysis in healthy pregnant women
Revista Brasileira de Ginecologia e Obstetrícia
Fluxo expiratório máximo
Índice de massa corporal
Gravidez normal
Peak expiratory flow
Body mass index
Normal pregnancy
author_facet Gustavo Antonio Neppelenbroek
Francisco Mauad-Filho
Sérgio Pereira da Cunha
Geraldo Duarte
Antonio Gadelha Costa
Patrícia Spara
Glauce Maria Gelonezi
author_sort Gustavo Antonio Neppelenbroek
title Investigação do fluxo expiratório máximo em gestantes saudáveis Peak expiratory flow analysis in healthy pregnant women
title_short Investigação do fluxo expiratório máximo em gestantes saudáveis Peak expiratory flow analysis in healthy pregnant women
title_full Investigação do fluxo expiratório máximo em gestantes saudáveis Peak expiratory flow analysis in healthy pregnant women
title_fullStr Investigação do fluxo expiratório máximo em gestantes saudáveis Peak expiratory flow analysis in healthy pregnant women
title_full_unstemmed Investigação do fluxo expiratório máximo em gestantes saudáveis Peak expiratory flow analysis in healthy pregnant women
title_sort investigação do fluxo expiratório máximo em gestantes saudáveis peak expiratory flow analysis in healthy pregnant women
publisher Federação Brasileira das Sociedades de Ginecologia e Obstetrícia
series Revista Brasileira de Ginecologia e Obstetrícia
issn 0100-7203
publishDate 2005-01-01
description OBJETIVO: investigar os valores normais de fluxo expiratório máximo para gestantes normais, com uso de aparelho expiratório portátil (Mini-Wright Peak Flow Meter), relacionando as medidas obtidas com estatura, índice de massa corporal (IMC) e idade de cada paciente, ao longo da gestação. MÉTODOS: estudo prospectivo longitudinal com 26 grávidas acompanhadas do primeiro trimestre até 36 semanas, sendo examinadas a cada quatro semanas. Durante sete visitas, as gestantes exalaram forçadamente três vezes no aparelho respiratório portátil, sendo considerado o maior valor como fluxo expiratório máximo. Todas as medidas foram realizadas de forma assistida, pelo mesmo pesquisador. O coeficiente de Pearson foi utilizado para calcular as correlações entre fluxo e IMC, entre fluxo e estatura e entre fluxo e idade da paciente. RESULTADOS: a variação do fluxo na gestação pode ser determinada por fluxo = 328,32 0,07 x semana, com coeficiente de Pearson igual a zero. Para verificar se houve diferença entre os coeficientes de correlação entre IMC e fluxo, em cada intervalo estudado, comparou-se o menor coeficiente (0,47 da semana 30, fluxo = 123,49 + 7,64 x IMC) com o maior (0,59 da semana 34, fluxo = 87,77 + 9,05 x IMC) e foi obtido o valor de 0,22, entre as variáveis fluxo e IMC. Entre estatura e fluxo, houve correlação positiva (Pearson = 0,61), com fluxo = -477,47 + 497,38 x estatura. O coeficiente de correlação entre fluxo e idade foi de 0,24, não se obtendo equação linear neste caso. CONCLUSÕES: os valores de fluxo expiratório máximo não se modificaram ao longo da gestação. Fluxos mais elevados foram encontrados em pacientes mais altas. Gestantes com maiores IMC prévios à gestação apresentaram maiores fluxos. Não houve correlação entre fluxo e idade materna.<br>PURPOSE: to investigate the normal peak expiratory flow values in healthy pregnant women employing a portable expiratory apparatus (Mini-Wright Peak Flow Meter), and to relate the obtained measurements to each patient's height, body mass index (BMI) and age, along gestation. METHODS: a longitudinal prospective study including 26 pregnant women followed up from the first trimester to the 36th week of gestation and examined every four weeks. On the occasion of seven visits, the pregnant women performed forced exhaling into a portable expiratory apparatus three times, with the highest value being considered the peak expiratory flow. All measurements were made under the same investigator's supervision in order to reduce the margin of error. Pearson coefficient was used to calculate the correlation between flow and BMI, between flow and patient's height, and between flow and patient's age. RESULTS: the variation in flow values during pregnancy can be determined by flow = 328.32 -0.07 x week, with a Pearson coefficient equal to zero. To determine whether there was a difference in the correlation coefficients between BMI and flow, we compared the lowest coefficient (0.47 for week 30, flow = 123.49 + 7.64 x BMI) with the highest coefficient (0.59 for week 34, flow = 87.77 + 9.05 x BMI) of each studied time interval and obtained a value of 0.22, indicating a good correlation between the flow and BMI variables. There was a positive correlation between height and flow (Pearson = 0.61), with flow = -477.47 + 497.38 x height. The correlation coefficient between flow and age was 0.24, with the equation obtained in this case being non-linear. CONCLUSIONS: peak expiratory flow values did not change along gestation. Higher flows were observed in taller women. Pregnant women with a higher BMI before gestation presented higher flows. There was no correlation between flow and maternal age.
topic Fluxo expiratório máximo
Índice de massa corporal
Gravidez normal
Peak expiratory flow
Body mass index
Normal pregnancy
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-72032005000100008
work_keys_str_mv AT gustavoantonioneppelenbroek investigacaodofluxoexpiratoriomaximoemgestantessaudaveispeakexpiratoryflowanalysisinhealthypregnantwomen
AT franciscomauadfilho investigacaodofluxoexpiratoriomaximoemgestantessaudaveispeakexpiratoryflowanalysisinhealthypregnantwomen
AT sergiopereiradacunha investigacaodofluxoexpiratoriomaximoemgestantessaudaveispeakexpiratoryflowanalysisinhealthypregnantwomen
AT geraldoduarte investigacaodofluxoexpiratoriomaximoemgestantessaudaveispeakexpiratoryflowanalysisinhealthypregnantwomen
AT antoniogadelhacosta investigacaodofluxoexpiratoriomaximoemgestantessaudaveispeakexpiratoryflowanalysisinhealthypregnantwomen
AT patriciaspara investigacaodofluxoexpiratoriomaximoemgestantessaudaveispeakexpiratoryflowanalysisinhealthypregnantwomen
AT glaucemariagelonezi investigacaodofluxoexpiratoriomaximoemgestantessaudaveispeakexpiratoryflowanalysisinhealthypregnantwomen
_version_ 1725415821834977280
spelling doaj-9be9066ecebb46dba85d07bd054055822020-11-25T00:08:19ZengFederação Brasileira das Sociedades de Ginecologia e ObstetríciaRevista Brasileira de Ginecologia e Obstetrícia0100-72032005-01-01271374310.1590/S0100-72032005000100008Investigação do fluxo expiratório máximo em gestantes saudáveis Peak expiratory flow analysis in healthy pregnant womenGustavo Antonio NeppelenbroekFrancisco Mauad-FilhoSérgio Pereira da CunhaGeraldo DuarteAntonio Gadelha CostaPatrícia SparaGlauce Maria GeloneziOBJETIVO: investigar os valores normais de fluxo expiratório máximo para gestantes normais, com uso de aparelho expiratório portátil (Mini-Wright Peak Flow Meter), relacionando as medidas obtidas com estatura, índice de massa corporal (IMC) e idade de cada paciente, ao longo da gestação. MÉTODOS: estudo prospectivo longitudinal com 26 grávidas acompanhadas do primeiro trimestre até 36 semanas, sendo examinadas a cada quatro semanas. Durante sete visitas, as gestantes exalaram forçadamente três vezes no aparelho respiratório portátil, sendo considerado o maior valor como fluxo expiratório máximo. Todas as medidas foram realizadas de forma assistida, pelo mesmo pesquisador. O coeficiente de Pearson foi utilizado para calcular as correlações entre fluxo e IMC, entre fluxo e estatura e entre fluxo e idade da paciente. RESULTADOS: a variação do fluxo na gestação pode ser determinada por fluxo = 328,32 0,07 x semana, com coeficiente de Pearson igual a zero. Para verificar se houve diferença entre os coeficientes de correlação entre IMC e fluxo, em cada intervalo estudado, comparou-se o menor coeficiente (0,47 da semana 30, fluxo = 123,49 + 7,64 x IMC) com o maior (0,59 da semana 34, fluxo = 87,77 + 9,05 x IMC) e foi obtido o valor de 0,22, entre as variáveis fluxo e IMC. Entre estatura e fluxo, houve correlação positiva (Pearson = 0,61), com fluxo = -477,47 + 497,38 x estatura. O coeficiente de correlação entre fluxo e idade foi de 0,24, não se obtendo equação linear neste caso. CONCLUSÕES: os valores de fluxo expiratório máximo não se modificaram ao longo da gestação. Fluxos mais elevados foram encontrados em pacientes mais altas. Gestantes com maiores IMC prévios à gestação apresentaram maiores fluxos. Não houve correlação entre fluxo e idade materna.<br>PURPOSE: to investigate the normal peak expiratory flow values in healthy pregnant women employing a portable expiratory apparatus (Mini-Wright Peak Flow Meter), and to relate the obtained measurements to each patient's height, body mass index (BMI) and age, along gestation. METHODS: a longitudinal prospective study including 26 pregnant women followed up from the first trimester to the 36th week of gestation and examined every four weeks. On the occasion of seven visits, the pregnant women performed forced exhaling into a portable expiratory apparatus three times, with the highest value being considered the peak expiratory flow. All measurements were made under the same investigator's supervision in order to reduce the margin of error. Pearson coefficient was used to calculate the correlation between flow and BMI, between flow and patient's height, and between flow and patient's age. RESULTS: the variation in flow values during pregnancy can be determined by flow = 328.32 -0.07 x week, with a Pearson coefficient equal to zero. To determine whether there was a difference in the correlation coefficients between BMI and flow, we compared the lowest coefficient (0.47 for week 30, flow = 123.49 + 7.64 x BMI) with the highest coefficient (0.59 for week 34, flow = 87.77 + 9.05 x BMI) of each studied time interval and obtained a value of 0.22, indicating a good correlation between the flow and BMI variables. There was a positive correlation between height and flow (Pearson = 0.61), with flow = -477.47 + 497.38 x height. The correlation coefficient between flow and age was 0.24, with the equation obtained in this case being non-linear. CONCLUSIONS: peak expiratory flow values did not change along gestation. Higher flows were observed in taller women. Pregnant women with a higher BMI before gestation presented higher flows. There was no correlation between flow and maternal age.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-72032005000100008Fluxo expiratório máximoÍndice de massa corporalGravidez normalPeak expiratory flowBody mass indexNormal pregnancy