Comparison the Sensitivity of ELISA and DIG-ELISA for Serodiagnosis of Human Toxoplasmosis

Toxoplasmosis is one of the most common parasitic infection in human and other warm-blooded animals. Serological methods are reliable techniques actually used for diagnosis of toxoplasmosis. Comparison of sensitivity of ELISA and DIG-ELISA for diagnosis of human toxoplasmosis was the main objective...

Full description

Bibliographic Details
Main Authors: Abdolhosein Dalimi Asl, Kavous Solhjoo, Fatemeh Ghaffarifar
Format: Article
Language:fas
Published: Hamadan University of Medical Sciences 2003-06-01
Series:پزشکی بالینی ابن سینا
Subjects:
Online Access:http://sjh.umsha.ac.ir/article-1-680-en.html
id doaj-9bef7399ad8c4e1c8da9303a4ff79d71
record_format Article
spelling doaj-9bef7399ad8c4e1c8da9303a4ff79d712020-11-25T04:09:58ZfasHamadan University of Medical Sciencesپزشکی بالینی ابن سینا2588-722X2588-72382003-06-011012529Comparison the Sensitivity of ELISA and DIG-ELISA for Serodiagnosis of Human ToxoplasmosisAbdolhosein Dalimi Asl0Kavous Solhjoo1Fatemeh Ghaffarifar2 Toxoplasmosis is one of the most common parasitic infection in human and other warm-blooded animals. Serological methods are reliable techniques actually used for diagnosis of toxoplasmosis. Comparison of sensitivity of ELISA and DIG-ELISA for diagnosis of human toxoplasmosis was the main objective of the present work.           68 human serum samples (48 positive sera and 20 negative sera) were tested using ELISA and DIG-ELISA (Diffusion in Gel-ELISA). Among three dilutions of sera (1:1, 1:10 and 1:100) tested for evaluation, the serum dilution 1:100 was selected as cut off. In this dilution, diameter of reaction zone was 6.08mm. In ELISA, 1:200 serum dilution was selected as cut off and at this    dilution OD was 0.735.           The sensitivity and specificity of DIG-ELISA for serodiagnosis of toxoplasmosis at 1:100 serum dilution were 93.37% ,100% respectively while the sensitivity and specificity of ELISA (at 1:200 serum dilution) were 91.66% , 85% respectively.           The results of present study indicated that, DIG-ELISA in 1:100 serum dilution, in comparison with ELISA proved higher sensitivity and specificity for diagnosis of toxoplasmosis.http://sjh.umsha.ac.ir/article-1-680-en.htmldig-elisaelisahuman toxoplasmosisserodiagnosis
collection DOAJ
language fas
format Article
sources DOAJ
author Abdolhosein Dalimi Asl
Kavous Solhjoo
Fatemeh Ghaffarifar
spellingShingle Abdolhosein Dalimi Asl
Kavous Solhjoo
Fatemeh Ghaffarifar
Comparison the Sensitivity of ELISA and DIG-ELISA for Serodiagnosis of Human Toxoplasmosis
پزشکی بالینی ابن سینا
dig-elisa
elisa
human toxoplasmosis
serodiagnosis
author_facet Abdolhosein Dalimi Asl
Kavous Solhjoo
Fatemeh Ghaffarifar
author_sort Abdolhosein Dalimi Asl
title Comparison the Sensitivity of ELISA and DIG-ELISA for Serodiagnosis of Human Toxoplasmosis
title_short Comparison the Sensitivity of ELISA and DIG-ELISA for Serodiagnosis of Human Toxoplasmosis
title_full Comparison the Sensitivity of ELISA and DIG-ELISA for Serodiagnosis of Human Toxoplasmosis
title_fullStr Comparison the Sensitivity of ELISA and DIG-ELISA for Serodiagnosis of Human Toxoplasmosis
title_full_unstemmed Comparison the Sensitivity of ELISA and DIG-ELISA for Serodiagnosis of Human Toxoplasmosis
title_sort comparison the sensitivity of elisa and dig-elisa for serodiagnosis of human toxoplasmosis
publisher Hamadan University of Medical Sciences
series پزشکی بالینی ابن سینا
issn 2588-722X
2588-7238
publishDate 2003-06-01
description Toxoplasmosis is one of the most common parasitic infection in human and other warm-blooded animals. Serological methods are reliable techniques actually used for diagnosis of toxoplasmosis. Comparison of sensitivity of ELISA and DIG-ELISA for diagnosis of human toxoplasmosis was the main objective of the present work.           68 human serum samples (48 positive sera and 20 negative sera) were tested using ELISA and DIG-ELISA (Diffusion in Gel-ELISA). Among three dilutions of sera (1:1, 1:10 and 1:100) tested for evaluation, the serum dilution 1:100 was selected as cut off. In this dilution, diameter of reaction zone was 6.08mm. In ELISA, 1:200 serum dilution was selected as cut off and at this    dilution OD was 0.735.           The sensitivity and specificity of DIG-ELISA for serodiagnosis of toxoplasmosis at 1:100 serum dilution were 93.37% ,100% respectively while the sensitivity and specificity of ELISA (at 1:200 serum dilution) were 91.66% , 85% respectively.           The results of present study indicated that, DIG-ELISA in 1:100 serum dilution, in comparison with ELISA proved higher sensitivity and specificity for diagnosis of toxoplasmosis.
topic dig-elisa
elisa
human toxoplasmosis
serodiagnosis
url http://sjh.umsha.ac.ir/article-1-680-en.html
work_keys_str_mv AT abdolhoseindalimiasl comparisonthesensitivityofelisaanddigelisaforserodiagnosisofhumantoxoplasmosis
AT kavoussolhjoo comparisonthesensitivityofelisaanddigelisaforserodiagnosisofhumantoxoplasmosis
AT fatemehghaffarifar comparisonthesensitivityofelisaanddigelisaforserodiagnosisofhumantoxoplasmosis
_version_ 1724421078748495872