COAGULANT – POLYELECTROLYTE SYSTEM FOR THE CONDITIONING DIGESTED AND SONICATED SEWAGE SLUDGE

The article presents the results of research on the impact of inorganic coagulants and polyelectrolytes and their common action on sonicated digested sludge. Sonication of sludge samples was carried out under static conditions for 60, 120 and 180 seconds. The ultrasonic wave of f = 20 kHz and two di...

Full description

Bibliographic Details
Main Authors: Beata Bień, Jurand D. Bień
Format: Article
Language:Polish
Published: Polish Society of Ecological Engineering (PTIE) 2014-10-01
Series:Inżynieria Ekologiczna
Subjects:
Online Access:http://www.journalssystem.com/ie/Uklad-koagulant-polielektrolit-w-kondycjonowaniu-przefermentowanych-i-nadzwiekawianych-osadow-sciekowych,270,0,2.html
id doaj-9d02eb80514c4b94b97439df6080547c
record_format Article
spelling doaj-9d02eb80514c4b94b97439df6080547c2020-11-24T22:43:57ZpolPolish Society of Ecological Engineering (PTIE)Inżynieria Ekologiczna2081-139X2392-06292014-10-013814315510.12912/2081139X.41270COAGULANT – POLYELECTROLYTE SYSTEM FOR THE CONDITIONING DIGESTED AND SONICATED SEWAGE SLUDGEBeata Bień0Jurand D. Bień1Wydział Inżynierii Środowiska i Biotechnologii, Politechnika Częstochowska, ul. Dąbrowskiego 69, 42-200 CzęstochowaWydział Inżynierii Środowiska i Biotechnologii, Politechnika Częstochowska, ul. Dąbrowskiego 69, 42-200 CzęstochowaThe article presents the results of research on the impact of inorganic coagulants and polyelectrolytes and their common action on sonicated digested sludge. Sonication of sludge samples was carried out under static conditions for 60, 120 and 180 seconds. The ultrasonic wave of f = 20 kHz and two different amplitudes of A = 15.25 μm was used in tests. The coagulant PIX123 and the polyelectrolyte Zetag 8160 were used for conditioning. On the basis of CST test the doses of chemical reagents were chosen for conditioning. The results showed the effect of application of the PIX123 and Zetag 8160 and their combination on non-sonicated and sonicated sludge. The lowest CST was achieved for non-sonicated sludge while polyelectrolyte was applied. For sonicated sludge better results were achieved when PIX123 was used. The combination of coagulant and polyelectrolyte allowed to achieve COD reduction, but the best results were achieved for sludge prepared by PIX123. The application of Zetag8160 in this case was not satisfactory.http://www.journalssystem.com/ie/Uklad-koagulant-polielektrolit-w-kondycjonowaniu-przefermentowanych-i-nadzwiekawianych-osadow-sciekowych,270,0,2.htmlultrasonic desintegrationcoagulantpolyelectrolytesewage sludge
collection DOAJ
language Polish
format Article
sources DOAJ
author Beata Bień
Jurand D. Bień
spellingShingle Beata Bień
Jurand D. Bień
COAGULANT – POLYELECTROLYTE SYSTEM FOR THE CONDITIONING DIGESTED AND SONICATED SEWAGE SLUDGE
Inżynieria Ekologiczna
ultrasonic desintegration
coagulant
polyelectrolyte
sewage sludge
author_facet Beata Bień
Jurand D. Bień
author_sort Beata Bień
title COAGULANT – POLYELECTROLYTE SYSTEM FOR THE CONDITIONING DIGESTED AND SONICATED SEWAGE SLUDGE
title_short COAGULANT – POLYELECTROLYTE SYSTEM FOR THE CONDITIONING DIGESTED AND SONICATED SEWAGE SLUDGE
title_full COAGULANT – POLYELECTROLYTE SYSTEM FOR THE CONDITIONING DIGESTED AND SONICATED SEWAGE SLUDGE
title_fullStr COAGULANT – POLYELECTROLYTE SYSTEM FOR THE CONDITIONING DIGESTED AND SONICATED SEWAGE SLUDGE
title_full_unstemmed COAGULANT – POLYELECTROLYTE SYSTEM FOR THE CONDITIONING DIGESTED AND SONICATED SEWAGE SLUDGE
title_sort coagulant – polyelectrolyte system for the conditioning digested and sonicated sewage sludge
publisher Polish Society of Ecological Engineering (PTIE)
series Inżynieria Ekologiczna
issn 2081-139X
2392-0629
publishDate 2014-10-01
description The article presents the results of research on the impact of inorganic coagulants and polyelectrolytes and their common action on sonicated digested sludge. Sonication of sludge samples was carried out under static conditions for 60, 120 and 180 seconds. The ultrasonic wave of f = 20 kHz and two different amplitudes of A = 15.25 μm was used in tests. The coagulant PIX123 and the polyelectrolyte Zetag 8160 were used for conditioning. On the basis of CST test the doses of chemical reagents were chosen for conditioning. The results showed the effect of application of the PIX123 and Zetag 8160 and their combination on non-sonicated and sonicated sludge. The lowest CST was achieved for non-sonicated sludge while polyelectrolyte was applied. For sonicated sludge better results were achieved when PIX123 was used. The combination of coagulant and polyelectrolyte allowed to achieve COD reduction, but the best results were achieved for sludge prepared by PIX123. The application of Zetag8160 in this case was not satisfactory.
topic ultrasonic desintegration
coagulant
polyelectrolyte
sewage sludge
url http://www.journalssystem.com/ie/Uklad-koagulant-polielektrolit-w-kondycjonowaniu-przefermentowanych-i-nadzwiekawianych-osadow-sciekowych,270,0,2.html
work_keys_str_mv AT beatabien coagulantpolyelectrolytesystemfortheconditioningdigestedandsonicatedsewagesludge
AT juranddbien coagulantpolyelectrolytesystemfortheconditioningdigestedandsonicatedsewagesludge
_version_ 1725693774775975936