Comparison of anaerobic threshold determined by visual and mathematical methods in healthy women

Several methods are used to estimate anaerobic threshold (AT) during exercise. The aim of the present study was to compare AT obtained by a graphic visual method for the estimate of ventilatory and metabolic variables (gold standard), to a bi-segmental linear regression mathematical model of Hinkley...

Full description

Bibliographic Details
Main Authors: M.N. Higa, E. Silva, V.F.C. Neves, A.M. Catai, L. Gallo Jr., M.F. Silva de Sá
Format: Article
Language:English
Published: Associação Brasileira de Divulgação Científica 2007-04-01
Series:Brazilian Journal of Medical and Biological Research
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-879X2007000400008
id doaj-9d81b4d829e44a8da167f66840583d7b
record_format Article
spelling doaj-9d81b4d829e44a8da167f66840583d7b2020-11-24T23:27:02ZengAssociação Brasileira de Divulgação CientíficaBrazilian Journal of Medical and Biological Research0100-879X1414-431X2007-04-01404501508Comparison of anaerobic threshold determined by visual and mathematical methods in healthy womenM.N. HigaE. SilvaV.F.C. NevesA.M. CataiL. Gallo Jr.M.F. Silva de SáSeveral methods are used to estimate anaerobic threshold (AT) during exercise. The aim of the present study was to compare AT obtained by a graphic visual method for the estimate of ventilatory and metabolic variables (gold standard), to a bi-segmental linear regression mathematical model of Hinkley's algorithm applied to heart rate (HR) and carbon dioxide output (VCO2) data. Thirteen young (24 ± 2.63 years old) and 16 postmenopausal (57 ± 4.79 years old) healthy and sedentary women were submitted to a continuous ergospirometric incremental test on an electromagnetic braking cycloergometer with 10 to 20 W/min increases until physical exhaustion. The ventilatory variables were recorded breath-to-breath and HR was obtained beat-to-beat over real time. Data were analyzed by the nonparametric Friedman test and Spearman correlation test with the level of significance set at 5%. Power output (W), HR (bpm), oxygen uptake (VO2; mL kg-1 min-1), VO2 (mL/min), VCO2 (mL/min), and minute ventilation (VE; L/min) data observed at the AT level were similar for both methods and groups studied (P > 0.05). The VO2 (mL kg-1 min-1) data showed significant correlation (P < 0.05) between the gold standard method and the mathematical model when applied to HR (r s = 0.75) and VCO2 (r s = 0.78) data for the subjects as a whole (N = 29). The proposed mathematical method for the detection of changes in response patterns of VCO2 and HR was adequate and promising for AT detection in young and middle-aged women, representing a semi-automatic, non-invasive and objective AT measurement.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-879X2007000400008Anaerobic thresholdIncremental testGraphic visual methodMathematical modelHinkley's algorithm
collection DOAJ
language English
format Article
sources DOAJ
author M.N. Higa
E. Silva
V.F.C. Neves
A.M. Catai
L. Gallo Jr.
M.F. Silva de Sá
spellingShingle M.N. Higa
E. Silva
V.F.C. Neves
A.M. Catai
L. Gallo Jr.
M.F. Silva de Sá
Comparison of anaerobic threshold determined by visual and mathematical methods in healthy women
Brazilian Journal of Medical and Biological Research
Anaerobic threshold
Incremental test
Graphic visual method
Mathematical model
Hinkley's algorithm
author_facet M.N. Higa
E. Silva
V.F.C. Neves
A.M. Catai
L. Gallo Jr.
M.F. Silva de Sá
author_sort M.N. Higa
title Comparison of anaerobic threshold determined by visual and mathematical methods in healthy women
title_short Comparison of anaerobic threshold determined by visual and mathematical methods in healthy women
title_full Comparison of anaerobic threshold determined by visual and mathematical methods in healthy women
title_fullStr Comparison of anaerobic threshold determined by visual and mathematical methods in healthy women
title_full_unstemmed Comparison of anaerobic threshold determined by visual and mathematical methods in healthy women
title_sort comparison of anaerobic threshold determined by visual and mathematical methods in healthy women
publisher Associação Brasileira de Divulgação Científica
series Brazilian Journal of Medical and Biological Research
issn 0100-879X
1414-431X
publishDate 2007-04-01
description Several methods are used to estimate anaerobic threshold (AT) during exercise. The aim of the present study was to compare AT obtained by a graphic visual method for the estimate of ventilatory and metabolic variables (gold standard), to a bi-segmental linear regression mathematical model of Hinkley's algorithm applied to heart rate (HR) and carbon dioxide output (VCO2) data. Thirteen young (24 ± 2.63 years old) and 16 postmenopausal (57 ± 4.79 years old) healthy and sedentary women were submitted to a continuous ergospirometric incremental test on an electromagnetic braking cycloergometer with 10 to 20 W/min increases until physical exhaustion. The ventilatory variables were recorded breath-to-breath and HR was obtained beat-to-beat over real time. Data were analyzed by the nonparametric Friedman test and Spearman correlation test with the level of significance set at 5%. Power output (W), HR (bpm), oxygen uptake (VO2; mL kg-1 min-1), VO2 (mL/min), VCO2 (mL/min), and minute ventilation (VE; L/min) data observed at the AT level were similar for both methods and groups studied (P > 0.05). The VO2 (mL kg-1 min-1) data showed significant correlation (P < 0.05) between the gold standard method and the mathematical model when applied to HR (r s = 0.75) and VCO2 (r s = 0.78) data for the subjects as a whole (N = 29). The proposed mathematical method for the detection of changes in response patterns of VCO2 and HR was adequate and promising for AT detection in young and middle-aged women, representing a semi-automatic, non-invasive and objective AT measurement.
topic Anaerobic threshold
Incremental test
Graphic visual method
Mathematical model
Hinkley's algorithm
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-879X2007000400008
work_keys_str_mv AT mnhiga comparisonofanaerobicthresholddeterminedbyvisualandmathematicalmethodsinhealthywomen
AT esilva comparisonofanaerobicthresholddeterminedbyvisualandmathematicalmethodsinhealthywomen
AT vfcneves comparisonofanaerobicthresholddeterminedbyvisualandmathematicalmethodsinhealthywomen
AT amcatai comparisonofanaerobicthresholddeterminedbyvisualandmathematicalmethodsinhealthywomen
AT lgallojr comparisonofanaerobicthresholddeterminedbyvisualandmathematicalmethodsinhealthywomen
AT mfsilvadesa comparisonofanaerobicthresholddeterminedbyvisualandmathematicalmethodsinhealthywomen
_version_ 1725553626078773248