Analysis and discussion on the experimental data of electrolyte analyzer

In the subsequent verification of electrolyte analyzer, we found that the instrument can achieve good repeatability and stability in repeated measurements with a short period of time, in line with the requirements of verification regulation of linear error and cross contamination rate, but the pheno...

Full description

Bibliographic Details
Main Authors: Dong XinYu, Jiang JunJie, Liu MengJun, Li Weiwei
Format: Article
Language:English
Published: EDP Sciences 2018-01-01
Series:E3S Web of Conferences
Online Access:https://doi.org/10.1051/e3sconf/20183801039
id doaj-9dc9ef0f568d4036b86b30da7d838d30
record_format Article
spelling doaj-9dc9ef0f568d4036b86b30da7d838d302021-02-02T05:35:31ZengEDP SciencesE3S Web of Conferences2267-12422018-01-01380103910.1051/e3sconf/20183801039e3sconf_icemee2018_01039Analysis and discussion on the experimental data of electrolyte analyzerDong XinYuJiang JunJieLiu MengJunLi WeiweiIn the subsequent verification of electrolyte analyzer, we found that the instrument can achieve good repeatability and stability in repeated measurements with a short period of time, in line with the requirements of verification regulation of linear error and cross contamination rate, but the phenomenon of large indication error is very common, the measurement results of different manufacturers have great difference, in order to find and solve this problem, help enterprises to improve quality of product, to obtain accurate and reliable measurement data, we conducted the experimental evaluation of electrolyte analyzer, and the data were analyzed by statistical analysis.https://doi.org/10.1051/e3sconf/20183801039
collection DOAJ
language English
format Article
sources DOAJ
author Dong XinYu
Jiang JunJie
Liu MengJun
Li Weiwei
spellingShingle Dong XinYu
Jiang JunJie
Liu MengJun
Li Weiwei
Analysis and discussion on the experimental data of electrolyte analyzer
E3S Web of Conferences
author_facet Dong XinYu
Jiang JunJie
Liu MengJun
Li Weiwei
author_sort Dong XinYu
title Analysis and discussion on the experimental data of electrolyte analyzer
title_short Analysis and discussion on the experimental data of electrolyte analyzer
title_full Analysis and discussion on the experimental data of electrolyte analyzer
title_fullStr Analysis and discussion on the experimental data of electrolyte analyzer
title_full_unstemmed Analysis and discussion on the experimental data of electrolyte analyzer
title_sort analysis and discussion on the experimental data of electrolyte analyzer
publisher EDP Sciences
series E3S Web of Conferences
issn 2267-1242
publishDate 2018-01-01
description In the subsequent verification of electrolyte analyzer, we found that the instrument can achieve good repeatability and stability in repeated measurements with a short period of time, in line with the requirements of verification regulation of linear error and cross contamination rate, but the phenomenon of large indication error is very common, the measurement results of different manufacturers have great difference, in order to find and solve this problem, help enterprises to improve quality of product, to obtain accurate and reliable measurement data, we conducted the experimental evaluation of electrolyte analyzer, and the data were analyzed by statistical analysis.
url https://doi.org/10.1051/e3sconf/20183801039
work_keys_str_mv AT dongxinyu analysisanddiscussionontheexperimentaldataofelectrolyteanalyzer
AT jiangjunjie analysisanddiscussionontheexperimentaldataofelectrolyteanalyzer
AT liumengjun analysisanddiscussionontheexperimentaldataofelectrolyteanalyzer
AT liweiwei analysisanddiscussionontheexperimentaldataofelectrolyteanalyzer
_version_ 1724303299700588544