Agreement between clinical history method, Orbscan IIz, and Pentacam in estimating corneal power after myopic excimer laser surgery.

The purpose of this study was to investigate the agreement between the clinical history method (CHM), Orbscan IIz, and Pentacam in estimating corneal power after myopic excimer laser surgery. Fifty five patients who had myopic LASIK/PRK were recruited into this study. One eye of each patient was ran...

Full description

Bibliographic Details
Main Authors: Kaevalin Lekhanont, Manachai Nonpassopon, Khemruetai Wannarosapark, Varintorn Chuckpaiwong
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2015-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC4390196?pdf=render
id doaj-9df7ed9cc6414e638ef0f780b0cc1c4a
record_format Article
spelling doaj-9df7ed9cc6414e638ef0f780b0cc1c4a2020-11-25T00:25:35ZengPublic Library of Science (PLoS)PLoS ONE1932-62032015-01-01104e012372910.1371/journal.pone.0123729Agreement between clinical history method, Orbscan IIz, and Pentacam in estimating corneal power after myopic excimer laser surgery.Kaevalin LekhanontManachai NonpassoponKhemruetai WannarosaparkVarintorn ChuckpaiwongThe purpose of this study was to investigate the agreement between the clinical history method (CHM), Orbscan IIz, and Pentacam in estimating corneal power after myopic excimer laser surgery. Fifty five patients who had myopic LASIK/PRK were recruited into this study. One eye of each patient was randomly selected by a computer-generated process. At 6 months after surgery, postoperative corneal power was calculated from the CHM, Orbscan IIz total optical power at the 3.0 and 4.0 mm zones, and Pentacam equivalent keratometric readings (EKRs) at 3.0, 4.0, and 4.5 mm. Statistical analyses included multilevel models, Pearson's correlation test, and Bland-Altman plots. The Orbscan IIz 3.0-mm and 4.0 mm total optical power, and Pentacam 3.0-mm, 4.0-mm, and 4.5-mm EKR values had strong linear positive correlations with the CHM values (r = 0.90-0.94, P = <0.001, for all comparisons, Pearson's correlation). However, only Pentacam 3.0-mm EKR was not statistically different from CHM (P = 0.17, multilevel models). The mean 3.0- and 4.0-mm total optical powers of the Orbscan IIz were significantly flatter than the values derived from CHM, while the average EKRs of the Pentacam at 4.0 and 4.5 mm were significantly steeper. The mean Orbscan IIz 3.0-mm total optical power was the lowest keratometric reading compared to the other 5 values. Large 95% LoA was observed between each of these values, particularly EKRs, and those obtained with the CHM. The width of the 95% LoA was narrowest for Orbscan IIz 3.0-mm total optical power. In conclusion, the keratometric values extracted from these 3 methods were disparate, either because of a statistically significant difference in the mean values or moderate agreement between them. Therefore, they are not considered equivalent and cannot be used interchangeably.http://europepmc.org/articles/PMC4390196?pdf=render
collection DOAJ
language English
format Article
sources DOAJ
author Kaevalin Lekhanont
Manachai Nonpassopon
Khemruetai Wannarosapark
Varintorn Chuckpaiwong
spellingShingle Kaevalin Lekhanont
Manachai Nonpassopon
Khemruetai Wannarosapark
Varintorn Chuckpaiwong
Agreement between clinical history method, Orbscan IIz, and Pentacam in estimating corneal power after myopic excimer laser surgery.
PLoS ONE
author_facet Kaevalin Lekhanont
Manachai Nonpassopon
Khemruetai Wannarosapark
Varintorn Chuckpaiwong
author_sort Kaevalin Lekhanont
title Agreement between clinical history method, Orbscan IIz, and Pentacam in estimating corneal power after myopic excimer laser surgery.
title_short Agreement between clinical history method, Orbscan IIz, and Pentacam in estimating corneal power after myopic excimer laser surgery.
title_full Agreement between clinical history method, Orbscan IIz, and Pentacam in estimating corneal power after myopic excimer laser surgery.
title_fullStr Agreement between clinical history method, Orbscan IIz, and Pentacam in estimating corneal power after myopic excimer laser surgery.
title_full_unstemmed Agreement between clinical history method, Orbscan IIz, and Pentacam in estimating corneal power after myopic excimer laser surgery.
title_sort agreement between clinical history method, orbscan iiz, and pentacam in estimating corneal power after myopic excimer laser surgery.
publisher Public Library of Science (PLoS)
series PLoS ONE
issn 1932-6203
publishDate 2015-01-01
description The purpose of this study was to investigate the agreement between the clinical history method (CHM), Orbscan IIz, and Pentacam in estimating corneal power after myopic excimer laser surgery. Fifty five patients who had myopic LASIK/PRK were recruited into this study. One eye of each patient was randomly selected by a computer-generated process. At 6 months after surgery, postoperative corneal power was calculated from the CHM, Orbscan IIz total optical power at the 3.0 and 4.0 mm zones, and Pentacam equivalent keratometric readings (EKRs) at 3.0, 4.0, and 4.5 mm. Statistical analyses included multilevel models, Pearson's correlation test, and Bland-Altman plots. The Orbscan IIz 3.0-mm and 4.0 mm total optical power, and Pentacam 3.0-mm, 4.0-mm, and 4.5-mm EKR values had strong linear positive correlations with the CHM values (r = 0.90-0.94, P = <0.001, for all comparisons, Pearson's correlation). However, only Pentacam 3.0-mm EKR was not statistically different from CHM (P = 0.17, multilevel models). The mean 3.0- and 4.0-mm total optical powers of the Orbscan IIz were significantly flatter than the values derived from CHM, while the average EKRs of the Pentacam at 4.0 and 4.5 mm were significantly steeper. The mean Orbscan IIz 3.0-mm total optical power was the lowest keratometric reading compared to the other 5 values. Large 95% LoA was observed between each of these values, particularly EKRs, and those obtained with the CHM. The width of the 95% LoA was narrowest for Orbscan IIz 3.0-mm total optical power. In conclusion, the keratometric values extracted from these 3 methods were disparate, either because of a statistically significant difference in the mean values or moderate agreement between them. Therefore, they are not considered equivalent and cannot be used interchangeably.
url http://europepmc.org/articles/PMC4390196?pdf=render
work_keys_str_mv AT kaevalinlekhanont agreementbetweenclinicalhistorymethodorbscaniizandpentacaminestimatingcornealpoweraftermyopicexcimerlasersurgery
AT manachainonpassopon agreementbetweenclinicalhistorymethodorbscaniizandpentacaminestimatingcornealpoweraftermyopicexcimerlasersurgery
AT khemruetaiwannarosapark agreementbetweenclinicalhistorymethodorbscaniizandpentacaminestimatingcornealpoweraftermyopicexcimerlasersurgery
AT varintornchuckpaiwong agreementbetweenclinicalhistorymethodorbscaniizandpentacaminestimatingcornealpoweraftermyopicexcimerlasersurgery
_version_ 1725348233684713472