Study on Turn-to-turn Short Circuit On一line Monitoring System for Dry一type Ai r一core Reactor
The change of current value caused by turn-to-turn short circuit of dry-type air-core reactor is so little that failure detection is difficult to be carried out. In order to solve this problem,a new on-line monitoring system based on impedance variation of turn-to-turn short circuit is proposed. The...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | zho |
Published: |
Harbin University of Science and Technology Publications
2017-04-01
|
Series: | Journal of Harbin University of Science and Technology |
Subjects: |
id |
doaj-9f13f5a1825144c5a03e7baeb9ed1667 |
---|---|
record_format |
Article |
spelling |
doaj-9f13f5a1825144c5a03e7baeb9ed16672020-11-25T01:24:47ZzhoHarbin University of Science and Technology PublicationsJournal of Harbin University of Science and Technology1007-26832017-04-01677110.15938/j.jhust.2017.02.013Study on Turn-to-turn Short Circuit On一line Monitoring System for Dry一type Ai r一core ReactorGAO Zi-wei ZHU Xue-chengWANG Yong-hongThe change of current value caused by turn-to-turn short circuit of dry-type air-core reactor is so little that failure detection is difficult to be carried out. In order to solve this problem,a new on-line monitoring system based on impedance variation of turn-to-turn short circuit is proposed. The numerical method is applied to analyze the variation of equivalent resistance and equivalent reactance when dry-type air-core reactor winding short circuit happens in different places,and the monitoring method based on harmonic analysis method and quasi- synchronization sampling method is analyzed by theory. The hardware system,which takes single-chip microcomputer as the core of data processing and logic control,completes data acquisition of voltage signal and current signal of the reactor. In the respect of software design,the impedance variation will be uploaded to the PC after it has been calculated by using the above monitoring method,and then monitoring of turn-to-turn short circuit fault will be realized. Finally,the design of on-line monitoring system is studied by testing. The research result shows that,the equivalent resistance increases and the equivalent reactance decreases when turn-to-turn short circuit occurs,and the variation of equivalent resistance is more obvious than equivalent reactance. The experiment results prove that this monitoring method is true and the on-line monitoring system is feasible.dry-type 月} r-core reactor; turn-to-turn short circuit; impedance variation; on-line monitoring |
collection |
DOAJ |
language |
zho |
format |
Article |
sources |
DOAJ |
author |
GAO Zi-wei ZHU Xue-cheng WANG Yong-hong |
spellingShingle |
GAO Zi-wei ZHU Xue-cheng WANG Yong-hong Study on Turn-to-turn Short Circuit On一line Monitoring System for Dry一type Ai r一core Reactor Journal of Harbin University of Science and Technology dry-type 月} r-core reactor; turn-to-turn short circuit; impedance variation; on-line monitoring |
author_facet |
GAO Zi-wei ZHU Xue-cheng WANG Yong-hong |
author_sort |
GAO Zi-wei |
title |
Study on Turn-to-turn Short Circuit On一line Monitoring System for Dry一type Ai r一core Reactor |
title_short |
Study on Turn-to-turn Short Circuit On一line Monitoring System for Dry一type Ai r一core Reactor |
title_full |
Study on Turn-to-turn Short Circuit On一line Monitoring System for Dry一type Ai r一core Reactor |
title_fullStr |
Study on Turn-to-turn Short Circuit On一line Monitoring System for Dry一type Ai r一core Reactor |
title_full_unstemmed |
Study on Turn-to-turn Short Circuit On一line Monitoring System for Dry一type Ai r一core Reactor |
title_sort |
study on turn-to-turn short circuit on一line monitoring system for dry一type ai r一core reactor |
publisher |
Harbin University of Science and Technology Publications |
series |
Journal of Harbin University of Science and Technology |
issn |
1007-2683 |
publishDate |
2017-04-01 |
description |
The change of current value caused by turn-to-turn short circuit of dry-type air-core reactor is so little that failure detection is difficult to be carried out. In order to solve this problem,a new on-line monitoring system based on impedance variation of turn-to-turn short circuit is proposed. The numerical method is applied to analyze the variation of equivalent resistance and equivalent reactance when dry-type air-core reactor winding short circuit happens in different places,and the monitoring method based on harmonic analysis method and quasi- synchronization sampling method is analyzed by theory. The hardware system,which takes single-chip microcomputer as the core of data processing and logic control,completes data acquisition of voltage signal and current signal of the reactor. In the respect of software design,the impedance variation will be uploaded to the PC after it has been calculated by using the above monitoring method,and then monitoring of turn-to-turn short circuit fault will be realized. Finally,the design of on-line monitoring system is studied by testing. The research result shows that,the equivalent resistance increases and the equivalent reactance decreases when turn-to-turn short circuit occurs,and the variation of equivalent resistance is more obvious than equivalent reactance. The experiment results prove that this monitoring method is true and the on-line monitoring system is feasible. |
topic |
dry-type 月} r-core reactor; turn-to-turn short circuit; impedance variation; on-line monitoring |
work_keys_str_mv |
AT gaoziwei studyonturntoturnshortcircuitonyīlinemonitoringsystemfordryyītypeairyīcorereactor AT zhuxuecheng studyonturntoturnshortcircuitonyīlinemonitoringsystemfordryyītypeairyīcorereactor AT wangyonghong studyonturntoturnshortcircuitonyīlinemonitoringsystemfordryyītypeairyīcorereactor |