Verification of the Seismic Performance of a Rigidly Connected Modular System Depending on the Shape and Size of the Ceiling Bracket

Modular systems have been mostly researched in relatively low-rise structures but, lately, their applications to mid- to high-rise structures began to be reviewed, and research interest in new modularization subjects has increased. The application of modular systems to mid- to high-rise structures r...

Full description

Bibliographic Details
Main Authors: Seungjae Lee, Jaeseong Park, Euishin Kwak, Sudeok Shon, Changhoon Kang, Hosoon Choi
Format: Article
Language:English
Published: MDPI AG 2017-03-01
Series:Materials
Subjects:
Online Access:http://www.mdpi.com/1996-1944/10/3/263
id doaj-a1fc85af7a604db192b523d010da841d
record_format Article
spelling doaj-a1fc85af7a604db192b523d010da841d2020-11-25T00:35:47ZengMDPI AGMaterials1996-19442017-03-0110326310.3390/ma10030263ma10030263Verification of the Seismic Performance of a Rigidly Connected Modular System Depending on the Shape and Size of the Ceiling BracketSeungjae Lee0Jaeseong Park1Euishin Kwak2Sudeok Shon3Changhoon Kang4Hosoon Choi5Interdisciplinary Program in Creative Engineering, Korea University of Technology and Education, Cheonan 31253, KoreaInterdisciplinary Program in Creative Engineering, Korea University of Technology and Education, Cheonan 31253, KoreaInterdisciplinary Program in Creative Engineering, Korea University of Technology and Education, Cheonan 31253, KoreaDepartment of Architectural Engineering, Korea University of Technology and Education, Cheonan 31253, KoreaStructure Design Team, Hyundai Engineering Co., Ltd., 75 Yulgok-ro, Jongno-gu, Seoul 03058, KoreaStructure Design Team, Hyundai Engineering Co., Ltd., 75 Yulgok-ro, Jongno-gu, Seoul 03058, KoreaModular systems have been mostly researched in relatively low-rise structures but, lately, their applications to mid- to high-rise structures began to be reviewed, and research interest in new modularization subjects has increased. The application of modular systems to mid- to high-rise structures requires the structural stability of the frame and connections that consist of units, and the evaluation of the stiffness of structures that are combined in units. However, the combination of general units causes loss of the cross-section of columns or beams, resulting in low seismic performance and hindering installation works in the field. In addition, the evaluation of a frame considering such a cross-sectional loss is not easy. Therefore, it is necessary to develop a joint that is stable and easy to install. In the study, a rigidly connected modular system was proposed as a moment-resisting frame for a unit modular system, and their joints were developed and their performances were compared. The proposed system changed the ceiling beam into a bracket type to fasten bolts. It can be merged with other seismic force-resisting systems. To verify the seismic performance of the proposed system, a cyclic loading test was conducted, and the rigidly connected joint performance and integrated behavior at the joint of modular units were investigated. From the experimental results, the maximum resisting force of the proposed connection exceeded the theoretical parameters, indicating that a rigid joint structural performance could be secured.http://www.mdpi.com/1996-1944/10/3/263modular systemcyclic loading testseismic performancecolumn-beam connectionrigidly-connected jointceiling bracket
collection DOAJ
language English
format Article
sources DOAJ
author Seungjae Lee
Jaeseong Park
Euishin Kwak
Sudeok Shon
Changhoon Kang
Hosoon Choi
spellingShingle Seungjae Lee
Jaeseong Park
Euishin Kwak
Sudeok Shon
Changhoon Kang
Hosoon Choi
Verification of the Seismic Performance of a Rigidly Connected Modular System Depending on the Shape and Size of the Ceiling Bracket
Materials
modular system
cyclic loading test
seismic performance
column-beam connection
rigidly-connected joint
ceiling bracket
author_facet Seungjae Lee
Jaeseong Park
Euishin Kwak
Sudeok Shon
Changhoon Kang
Hosoon Choi
author_sort Seungjae Lee
title Verification of the Seismic Performance of a Rigidly Connected Modular System Depending on the Shape and Size of the Ceiling Bracket
title_short Verification of the Seismic Performance of a Rigidly Connected Modular System Depending on the Shape and Size of the Ceiling Bracket
title_full Verification of the Seismic Performance of a Rigidly Connected Modular System Depending on the Shape and Size of the Ceiling Bracket
title_fullStr Verification of the Seismic Performance of a Rigidly Connected Modular System Depending on the Shape and Size of the Ceiling Bracket
title_full_unstemmed Verification of the Seismic Performance of a Rigidly Connected Modular System Depending on the Shape and Size of the Ceiling Bracket
title_sort verification of the seismic performance of a rigidly connected modular system depending on the shape and size of the ceiling bracket
publisher MDPI AG
series Materials
issn 1996-1944
publishDate 2017-03-01
description Modular systems have been mostly researched in relatively low-rise structures but, lately, their applications to mid- to high-rise structures began to be reviewed, and research interest in new modularization subjects has increased. The application of modular systems to mid- to high-rise structures requires the structural stability of the frame and connections that consist of units, and the evaluation of the stiffness of structures that are combined in units. However, the combination of general units causes loss of the cross-section of columns or beams, resulting in low seismic performance and hindering installation works in the field. In addition, the evaluation of a frame considering such a cross-sectional loss is not easy. Therefore, it is necessary to develop a joint that is stable and easy to install. In the study, a rigidly connected modular system was proposed as a moment-resisting frame for a unit modular system, and their joints were developed and their performances were compared. The proposed system changed the ceiling beam into a bracket type to fasten bolts. It can be merged with other seismic force-resisting systems. To verify the seismic performance of the proposed system, a cyclic loading test was conducted, and the rigidly connected joint performance and integrated behavior at the joint of modular units were investigated. From the experimental results, the maximum resisting force of the proposed connection exceeded the theoretical parameters, indicating that a rigid joint structural performance could be secured.
topic modular system
cyclic loading test
seismic performance
column-beam connection
rigidly-connected joint
ceiling bracket
url http://www.mdpi.com/1996-1944/10/3/263
work_keys_str_mv AT seungjaelee verificationoftheseismicperformanceofarigidlyconnectedmodularsystemdependingontheshapeandsizeoftheceilingbracket
AT jaeseongpark verificationoftheseismicperformanceofarigidlyconnectedmodularsystemdependingontheshapeandsizeoftheceilingbracket
AT euishinkwak verificationoftheseismicperformanceofarigidlyconnectedmodularsystemdependingontheshapeandsizeoftheceilingbracket
AT sudeokshon verificationoftheseismicperformanceofarigidlyconnectedmodularsystemdependingontheshapeandsizeoftheceilingbracket
AT changhoonkang verificationoftheseismicperformanceofarigidlyconnectedmodularsystemdependingontheshapeandsizeoftheceilingbracket
AT hosoonchoi verificationoftheseismicperformanceofarigidlyconnectedmodularsystemdependingontheshapeandsizeoftheceilingbracket
_version_ 1725307687738015744