Clinical Experience of Using Intraocular Lenses

Aim: to analyze the data obtained from using of intraocular lenses — the hydrophobic IOL Citrin and a hydrophilic IOL Aquamarine, produced by Russian company — NanOptic. Materials and methods. A total of 56 IOLs, produced by NanOptic (38 hydrophobic IOLs Citrine and 18 hydrophilic IOLs Aquamarine) w...

Full description

Bibliographic Details
Main Authors: A. D. Chernysheva, V. O. Afanasyeva
Format: Article
Language:Russian
Published: Ophthalmology Publishing Group 2019-10-01
Series:Oftalʹmologiâ
Subjects:
Online Access:https://www.ophthalmojournal.com/opht/article/view/1007
id doaj-a28bc2fddcbc49589fa97c7683ef0f12
record_format Article
spelling doaj-a28bc2fddcbc49589fa97c7683ef0f122021-07-29T08:55:28ZrusOphthalmology Publishing GroupOftalʹmologiâ 1816-50952019-10-0116330430910.18008/1816-5095-2019-3-304-309555Clinical Experience of Using Intraocular LensesA. D. Chernysheva0V. O. Afanasyeva1“Grand Medica”“Grand Medica”Aim: to analyze the data obtained from using of intraocular lenses — the hydrophobic IOL Citrin and a hydrophilic IOL Aquamarine, produced by Russian company — NanOptic. Materials and methods. A total of 56 IOLs, produced by NanOptic (38 hydrophobic IOLs Citrine and 18 hydrophilic IOLs Aquamarine) were implanted. The observation period was from 3 to 12 months. The indication for phacoemulsification was age cataract. The age of the patients was 54–85. Patients before the operation were conducted basic studies. The mean uncorrected visual acuity before the operation was (UCVA) 0.121 ± 0.120 (0.001–0.3), and the mean corrected visual acuity was (BCVA) 0.187 ± 0.140 (0.001–0.6). All patients underwent standard phacoemulsification. Results. The early postoperative period was without any complications. In the postoperative period the mean UCVA in patients with “Citrine” and “Aquamarine” was 0.90 ± 0.10 (0.7–1.0) and 0.96 ± 0.07 (0.8–1.0) accordingly, and the mean BCVA was 0.94 ± 0.07 (0.8–1.0) and 0.99 ± 0.02 (0.9–1.0) accordingly. In all cases, the refraction obtained was consistent with the prediction. The error in IOL calculation was minimal and permissible. There weren’t any case of secondary cataract in patients with hydrophobic IOLs, and 3 cases of lens posterior capsule fibrosis of 1 degree in patients with hydrophilic IOLs in 3–12 months observation. The position of IOL in capsule bag was stable. Conclusions. The results of implantation of new Russian-made IOLs on the given parameters appeared to be satisfactory, that allows to recommend them for implantation in cataract surgery.https://www.ophthalmojournal.com/opht/article/view/1007hydrophilic iol “aquamarine”hydrophobic iol “citrine”nanopticphacoemulsification of cataractiol implantation
collection DOAJ
language Russian
format Article
sources DOAJ
author A. D. Chernysheva
V. O. Afanasyeva
spellingShingle A. D. Chernysheva
V. O. Afanasyeva
Clinical Experience of Using Intraocular Lenses
Oftalʹmologiâ
hydrophilic iol “aquamarine”
hydrophobic iol “citrine”
nanoptic
phacoemulsification of cataract
iol implantation
author_facet A. D. Chernysheva
V. O. Afanasyeva
author_sort A. D. Chernysheva
title Clinical Experience of Using Intraocular Lenses
title_short Clinical Experience of Using Intraocular Lenses
title_full Clinical Experience of Using Intraocular Lenses
title_fullStr Clinical Experience of Using Intraocular Lenses
title_full_unstemmed Clinical Experience of Using Intraocular Lenses
title_sort clinical experience of using intraocular lenses
publisher Ophthalmology Publishing Group
series Oftalʹmologiâ
issn 1816-5095
publishDate 2019-10-01
description Aim: to analyze the data obtained from using of intraocular lenses — the hydrophobic IOL Citrin and a hydrophilic IOL Aquamarine, produced by Russian company — NanOptic. Materials and methods. A total of 56 IOLs, produced by NanOptic (38 hydrophobic IOLs Citrine and 18 hydrophilic IOLs Aquamarine) were implanted. The observation period was from 3 to 12 months. The indication for phacoemulsification was age cataract. The age of the patients was 54–85. Patients before the operation were conducted basic studies. The mean uncorrected visual acuity before the operation was (UCVA) 0.121 ± 0.120 (0.001–0.3), and the mean corrected visual acuity was (BCVA) 0.187 ± 0.140 (0.001–0.6). All patients underwent standard phacoemulsification. Results. The early postoperative period was without any complications. In the postoperative period the mean UCVA in patients with “Citrine” and “Aquamarine” was 0.90 ± 0.10 (0.7–1.0) and 0.96 ± 0.07 (0.8–1.0) accordingly, and the mean BCVA was 0.94 ± 0.07 (0.8–1.0) and 0.99 ± 0.02 (0.9–1.0) accordingly. In all cases, the refraction obtained was consistent with the prediction. The error in IOL calculation was minimal and permissible. There weren’t any case of secondary cataract in patients with hydrophobic IOLs, and 3 cases of lens posterior capsule fibrosis of 1 degree in patients with hydrophilic IOLs in 3–12 months observation. The position of IOL in capsule bag was stable. Conclusions. The results of implantation of new Russian-made IOLs on the given parameters appeared to be satisfactory, that allows to recommend them for implantation in cataract surgery.
topic hydrophilic iol “aquamarine”
hydrophobic iol “citrine”
nanoptic
phacoemulsification of cataract
iol implantation
url https://www.ophthalmojournal.com/opht/article/view/1007
work_keys_str_mv AT adchernysheva clinicalexperienceofusingintraocularlenses
AT voafanasyeva clinicalexperienceofusingintraocularlenses
_version_ 1721250961101422592