Flow rate dynamics of pressure-compensating drippers under clogging effect

ABSTRACT The clogging dynamics of pressure-compensating drippers is still poorly addressed, and its understanding is quite important to control clogging. The aim of this study was to evaluate the flow performance of pressure-compensating drippers under clogging effect. Eight pressure-compensating em...

Full description

Bibliographic Details
Main Authors: Marinaldo F. Pinto, Bruno Molle, Dinara G. Alves, Nassim Ait-Mouheb, Antonio P. de Camargo, José A. Frizzone
Format: Article
Language:English
Published: Universidade Federal de Campina Grande
Series:Revista Brasileira de Engenharia Agrícola e Ambiental - Agriambi
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1415-43662017000500304&lng=en&tlng=en
id doaj-a360bb9f53a8456ba4ca895ed21adaa4
record_format Article
spelling doaj-a360bb9f53a8456ba4ca895ed21adaa42020-11-25T02:44:03ZengUniversidade Federal de Campina GrandeRevista Brasileira de Engenharia Agrícola e Ambiental - Agriambi1807-192921530430910.1590/1807-1929/agriambi.v21n5p304-309S1415-43662017000500304Flow rate dynamics of pressure-compensating drippers under clogging effectMarinaldo F. PintoBruno MolleDinara G. AlvesNassim Ait-MouhebAntonio P. de CamargoJosé A. FrizzoneABSTRACT The clogging dynamics of pressure-compensating drippers is still poorly addressed, and its understanding is quite important to control clogging. The aim of this study was to evaluate the flow performance of pressure-compensating drippers under clogging effect. Eight pressure-compensating emitters, model J-SC Jain PC-PLUS with nominal flow rate of 2.2 L h-1 were evaluated. The tests were run for 8 h d-1 for 4 weeks, a total of 160 h. Every 40 h, the concentration and granulometry of suspended particles were increased, by adding 125 mg L-1 of solids, composed of sand. The flow rate of the emitters was determined using a weight measurement system. Flow rate variations of the emitters did not follow a defined pattern. Clogging seems to occur randomly and abruptly. Sometimes the flow rate exceeded the nominal value (maximum relative flow rate of 182%) and other times it was lower than the nominal value (minimum relative flow rate of 0%).http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1415-43662017000500304&lng=en&tlng=enemissoresirrigação localizadaentupimento
collection DOAJ
language English
format Article
sources DOAJ
author Marinaldo F. Pinto
Bruno Molle
Dinara G. Alves
Nassim Ait-Mouheb
Antonio P. de Camargo
José A. Frizzone
spellingShingle Marinaldo F. Pinto
Bruno Molle
Dinara G. Alves
Nassim Ait-Mouheb
Antonio P. de Camargo
José A. Frizzone
Flow rate dynamics of pressure-compensating drippers under clogging effect
Revista Brasileira de Engenharia Agrícola e Ambiental - Agriambi
emissores
irrigação localizada
entupimento
author_facet Marinaldo F. Pinto
Bruno Molle
Dinara G. Alves
Nassim Ait-Mouheb
Antonio P. de Camargo
José A. Frizzone
author_sort Marinaldo F. Pinto
title Flow rate dynamics of pressure-compensating drippers under clogging effect
title_short Flow rate dynamics of pressure-compensating drippers under clogging effect
title_full Flow rate dynamics of pressure-compensating drippers under clogging effect
title_fullStr Flow rate dynamics of pressure-compensating drippers under clogging effect
title_full_unstemmed Flow rate dynamics of pressure-compensating drippers under clogging effect
title_sort flow rate dynamics of pressure-compensating drippers under clogging effect
publisher Universidade Federal de Campina Grande
series Revista Brasileira de Engenharia Agrícola e Ambiental - Agriambi
issn 1807-1929
description ABSTRACT The clogging dynamics of pressure-compensating drippers is still poorly addressed, and its understanding is quite important to control clogging. The aim of this study was to evaluate the flow performance of pressure-compensating drippers under clogging effect. Eight pressure-compensating emitters, model J-SC Jain PC-PLUS with nominal flow rate of 2.2 L h-1 were evaluated. The tests were run for 8 h d-1 for 4 weeks, a total of 160 h. Every 40 h, the concentration and granulometry of suspended particles were increased, by adding 125 mg L-1 of solids, composed of sand. The flow rate of the emitters was determined using a weight measurement system. Flow rate variations of the emitters did not follow a defined pattern. Clogging seems to occur randomly and abruptly. Sometimes the flow rate exceeded the nominal value (maximum relative flow rate of 182%) and other times it was lower than the nominal value (minimum relative flow rate of 0%).
topic emissores
irrigação localizada
entupimento
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1415-43662017000500304&lng=en&tlng=en
work_keys_str_mv AT marinaldofpinto flowratedynamicsofpressurecompensatingdrippersundercloggingeffect
AT brunomolle flowratedynamicsofpressurecompensatingdrippersundercloggingeffect
AT dinaragalves flowratedynamicsofpressurecompensatingdrippersundercloggingeffect
AT nassimaitmouheb flowratedynamicsofpressurecompensatingdrippersundercloggingeffect
AT antoniopdecamargo flowratedynamicsofpressurecompensatingdrippersundercloggingeffect
AT joseafrizzone flowratedynamicsofpressurecompensatingdrippersundercloggingeffect
_version_ 1724767754325590016