Area under the forced expiratory flow-volume loop in spirometry indicates severe hyperinflation in COPD patients

Nilakash Das,1 Marko Topalovic,1 Jean-Marie Aerts,2 Wim Janssens1 1Laboratory of Respiratory Diseases, Department of Chronic Diseases, Metabolism and Ageing, Katholieke Universiteit Leuven, Leuven, Belgium; 2Division of Animal and Human Health Engineering, Department of Biosystems, Katholieke Unive...

Full description

Bibliographic Details
Main Authors: Das N, Topalovic M, Aerts JM, Janssens W
Format: Article
Language:English
Published: Dove Medical Press 2019-02-01
Series:International Journal of COPD
Subjects:
Online Access:https://www.dovepress.com/area-under-the-forced-expiratory-flow-volume-loop-in-spirometry-indica-peer-reviewed-article-COPD
id doaj-a4682ec35d32447fb5b9a61e7637d4ba
record_format Article
spelling doaj-a4682ec35d32447fb5b9a61e7637d4ba2020-11-24T21:18:07ZengDove Medical PressInternational Journal of COPD1178-20052019-02-01Volume 1440941844085Area under the forced expiratory flow-volume loop in spirometry indicates severe hyperinflation in COPD patientsDas NTopalovic MAerts JMJanssens WNilakash Das,1 Marko Topalovic,1 Jean-Marie Aerts,2 Wim Janssens1 1Laboratory of Respiratory Diseases, Department of Chronic Diseases, Metabolism and Ageing, Katholieke Universiteit Leuven, Leuven, Belgium; 2Division of Animal and Human Health Engineering, Department of Biosystems, Katholieke Universiteit Leuven, Leuven, Belgium Background: Severe hyperinflation causes detrimental effects such as dyspnea and reduced exercise capacity and is an independent predictor of mortality in COPD patients. Static lung volumes are required to diagnose severe hyperinflation, which are not always accessible in primary care. Several studies have shown that the area under the forced expiratory flow-volume loop (AreaFE) is highly sensitive to bronchodilator response and is correlated with residual volume/total lung capacity (RV/TLC), a common index of air trapping. In this study, we investigate the role of AreaFE% (AreaFE expressed as a percentage of reference value) and conventional spirometry parameters in indicating severe hyperinflation. Materials and methods: We used a cohort of 215 individuals with COPD. The presence of severe hyperinflation was defined as elevated air trapping (RV/TLC >60%) or reduced inspiratory fraction (inspiratory capacity [IC]/TLC <25%) measured using body plethysmography. AreaFE% was calculated by integrating the maximal expiratory flow-volume loop with the trapezoidal rule and expressing it as a percentage of the reference value estimated using predicted values of FVC, peak expiratory flow and forced expiratory flow at 25%, 50% and 75% of FVC. Receiver operating characteristics (ROC) curve analysis was used to identify cut-offs that were used to indicate severe hyperinflation, which were then validated in a separate group of 104 COPD subjects. Results: ROC analysis identified cut-offs of 15% and 20% for AreaFE% in indicating RV/TLC >60% and IC/TLC <25%, respectively (N=215). On validation (N=104), these cut-offs consistently registered the highest accuracy (80% each), sensitivity (68% and 75%) and specificity (83% and 80%) among conventional parameters in both criteria of severe hyperinflation. Conclusion: AreaFE% consistently provides a superior estimation of severe hyperinflation using different indices, and may provide a convenient way to refer COPD patients for body plethysmography to address static lung volumes. Keywords: spirometry, flow-volume loop, air trapping, severe hyperinflation, COPD, area under flow-volume loophttps://www.dovepress.com/area-under-the-forced-expiratory-flow-volume-loop-in-spirometry-indica-peer-reviewed-article-COPDSpirometryflow-volume loopair-trappingsevere hyperinflationchronic obstructive pulmonary disease;
collection DOAJ
language English
format Article
sources DOAJ
author Das N
Topalovic M
Aerts JM
Janssens W
spellingShingle Das N
Topalovic M
Aerts JM
Janssens W
Area under the forced expiratory flow-volume loop in spirometry indicates severe hyperinflation in COPD patients
International Journal of COPD
Spirometry
flow-volume loop
air-trapping
severe hyperinflation
chronic obstructive pulmonary disease;
author_facet Das N
Topalovic M
Aerts JM
Janssens W
author_sort Das N
title Area under the forced expiratory flow-volume loop in spirometry indicates severe hyperinflation in COPD patients
title_short Area under the forced expiratory flow-volume loop in spirometry indicates severe hyperinflation in COPD patients
title_full Area under the forced expiratory flow-volume loop in spirometry indicates severe hyperinflation in COPD patients
title_fullStr Area under the forced expiratory flow-volume loop in spirometry indicates severe hyperinflation in COPD patients
title_full_unstemmed Area under the forced expiratory flow-volume loop in spirometry indicates severe hyperinflation in COPD patients
title_sort area under the forced expiratory flow-volume loop in spirometry indicates severe hyperinflation in copd patients
publisher Dove Medical Press
series International Journal of COPD
issn 1178-2005
publishDate 2019-02-01
description Nilakash Das,1 Marko Topalovic,1 Jean-Marie Aerts,2 Wim Janssens1 1Laboratory of Respiratory Diseases, Department of Chronic Diseases, Metabolism and Ageing, Katholieke Universiteit Leuven, Leuven, Belgium; 2Division of Animal and Human Health Engineering, Department of Biosystems, Katholieke Universiteit Leuven, Leuven, Belgium Background: Severe hyperinflation causes detrimental effects such as dyspnea and reduced exercise capacity and is an independent predictor of mortality in COPD patients. Static lung volumes are required to diagnose severe hyperinflation, which are not always accessible in primary care. Several studies have shown that the area under the forced expiratory flow-volume loop (AreaFE) is highly sensitive to bronchodilator response and is correlated with residual volume/total lung capacity (RV/TLC), a common index of air trapping. In this study, we investigate the role of AreaFE% (AreaFE expressed as a percentage of reference value) and conventional spirometry parameters in indicating severe hyperinflation. Materials and methods: We used a cohort of 215 individuals with COPD. The presence of severe hyperinflation was defined as elevated air trapping (RV/TLC >60%) or reduced inspiratory fraction (inspiratory capacity [IC]/TLC <25%) measured using body plethysmography. AreaFE% was calculated by integrating the maximal expiratory flow-volume loop with the trapezoidal rule and expressing it as a percentage of the reference value estimated using predicted values of FVC, peak expiratory flow and forced expiratory flow at 25%, 50% and 75% of FVC. Receiver operating characteristics (ROC) curve analysis was used to identify cut-offs that were used to indicate severe hyperinflation, which were then validated in a separate group of 104 COPD subjects. Results: ROC analysis identified cut-offs of 15% and 20% for AreaFE% in indicating RV/TLC >60% and IC/TLC <25%, respectively (N=215). On validation (N=104), these cut-offs consistently registered the highest accuracy (80% each), sensitivity (68% and 75%) and specificity (83% and 80%) among conventional parameters in both criteria of severe hyperinflation. Conclusion: AreaFE% consistently provides a superior estimation of severe hyperinflation using different indices, and may provide a convenient way to refer COPD patients for body plethysmography to address static lung volumes. Keywords: spirometry, flow-volume loop, air trapping, severe hyperinflation, COPD, area under flow-volume loop
topic Spirometry
flow-volume loop
air-trapping
severe hyperinflation
chronic obstructive pulmonary disease;
url https://www.dovepress.com/area-under-the-forced-expiratory-flow-volume-loop-in-spirometry-indica-peer-reviewed-article-COPD
work_keys_str_mv AT dasn areaundertheforcedexpiratoryflowvolumeloopinspirometryindicatesseverehyperinflationincopdpatients
AT topalovicm areaundertheforcedexpiratoryflowvolumeloopinspirometryindicatesseverehyperinflationincopdpatients
AT aertsjm areaundertheforcedexpiratoryflowvolumeloopinspirometryindicatesseverehyperinflationincopdpatients
AT janssensw areaundertheforcedexpiratoryflowvolumeloopinspirometryindicatesseverehyperinflationincopdpatients
_version_ 1726010186530816000