Snare-assisted thoracic endovascular aortic repair for redirection of a false lumen elephant trunk
In recent years, a hybrid approach to the classic two-stage elephant trunk technique has come into favor for treatment of thoracic aortic dissection. During the first stage, inadvertent intraoperative placement of the elephant trunk into the false lumen can occur on rare occasions, resulting in unto...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2020-12-01
|
Series: | Journal of Vascular Surgery Cases and Innovative Techniques |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2468428720301295 |
id |
doaj-a4a3ff44f7f1435081519593f6e800ce |
---|---|
record_format |
Article |
spelling |
doaj-a4a3ff44f7f1435081519593f6e800ce2020-12-27T04:31:14ZengElsevierJournal of Vascular Surgery Cases and Innovative Techniques2468-42872020-12-0164566570Snare-assisted thoracic endovascular aortic repair for redirection of a false lumen elephant trunkJulia Fayanne Chen, MD0Abeel Mangi, MD1Prashanth Vallabhajosyula, MD2Naiem Nassiri, MD3Division of Vascular and Endovascular Surgery, Department of Surgery, Yale University School of Medicine, New Haven, Conn; Aortic Institute at Yale New Haven Hospital, Yale University School of Medicine, New Haven, ConnDivision of Cardiac Surgery, Department of Surgery, Yale University School of Medicine, New Haven, ConnAortic Institute at Yale New Haven Hospital, Yale University School of Medicine, New Haven, Conn; Division of Cardiac Surgery, Department of Surgery, Yale University School of Medicine, New Haven, ConnDivision of Vascular and Endovascular Surgery, Department of Surgery, Yale University School of Medicine, New Haven, Conn; Aortic Institute at Yale New Haven Hospital, Yale University School of Medicine, New Haven, Conn; Correspondence: Naiem Nassiri, MD, RPVI, Division of Vascular and Endovascular Surgery, Yale University School of Medicine, 330 Cedar St, Boardman 204, New Haven, CT 06520In recent years, a hybrid approach to the classic two-stage elephant trunk technique has come into favor for treatment of thoracic aortic dissection. During the first stage, inadvertent intraoperative placement of the elephant trunk into the false lumen can occur on rare occasions, resulting in untoward difficulties during the second stage of the procedure. We describe here a snare-assisted technique for endovascular salvage of an elephant trunk that had inadvertently been placed in the false lumen of a chronic aortic dissection.http://www.sciencedirect.com/science/article/pii/S2468428720301295Aortic dissectionTEVARFalse lumenElephant trunkSnare |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Julia Fayanne Chen, MD Abeel Mangi, MD Prashanth Vallabhajosyula, MD Naiem Nassiri, MD |
spellingShingle |
Julia Fayanne Chen, MD Abeel Mangi, MD Prashanth Vallabhajosyula, MD Naiem Nassiri, MD Snare-assisted thoracic endovascular aortic repair for redirection of a false lumen elephant trunk Journal of Vascular Surgery Cases and Innovative Techniques Aortic dissection TEVAR False lumen Elephant trunk Snare |
author_facet |
Julia Fayanne Chen, MD Abeel Mangi, MD Prashanth Vallabhajosyula, MD Naiem Nassiri, MD |
author_sort |
Julia Fayanne Chen, MD |
title |
Snare-assisted thoracic endovascular aortic repair for redirection of a false lumen elephant trunk |
title_short |
Snare-assisted thoracic endovascular aortic repair for redirection of a false lumen elephant trunk |
title_full |
Snare-assisted thoracic endovascular aortic repair for redirection of a false lumen elephant trunk |
title_fullStr |
Snare-assisted thoracic endovascular aortic repair for redirection of a false lumen elephant trunk |
title_full_unstemmed |
Snare-assisted thoracic endovascular aortic repair for redirection of a false lumen elephant trunk |
title_sort |
snare-assisted thoracic endovascular aortic repair for redirection of a false lumen elephant trunk |
publisher |
Elsevier |
series |
Journal of Vascular Surgery Cases and Innovative Techniques |
issn |
2468-4287 |
publishDate |
2020-12-01 |
description |
In recent years, a hybrid approach to the classic two-stage elephant trunk technique has come into favor for treatment of thoracic aortic dissection. During the first stage, inadvertent intraoperative placement of the elephant trunk into the false lumen can occur on rare occasions, resulting in untoward difficulties during the second stage of the procedure. We describe here a snare-assisted technique for endovascular salvage of an elephant trunk that had inadvertently been placed in the false lumen of a chronic aortic dissection. |
topic |
Aortic dissection TEVAR False lumen Elephant trunk Snare |
url |
http://www.sciencedirect.com/science/article/pii/S2468428720301295 |
work_keys_str_mv |
AT juliafayannechenmd snareassistedthoracicendovascularaorticrepairforredirectionofafalselumenelephanttrunk AT abeelmangimd snareassistedthoracicendovascularaorticrepairforredirectionofafalselumenelephanttrunk AT prashanthvallabhajosyulamd snareassistedthoracicendovascularaorticrepairforredirectionofafalselumenelephanttrunk AT naiemnassirimd snareassistedthoracicendovascularaorticrepairforredirectionofafalselumenelephanttrunk |
_version_ |
1724369783096344576 |