A morphometric study of glenoid cavity and its implication in shoulder arthroplasty and prosthetic designs

Background and aims: Glenoid cavity of scapula is known for its variable morphology. The variations in the shape of glenoid cavity are due to the presence of a notch in its antero-superior part. The glenoid cavity is small and allows only a limited area for fixation devices. Knowledge of its morphol...

Full description

Bibliographic Details
Main Authors: Shalom Elsy Philip, K R Dakshayani
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2018-01-01
Series:National Journal of Clinical Anatomy
Subjects:
Online Access:http://www.njca.info/article.asp?issn=2277-4025;year=2018;volume=7;issue=4;spage=190;epage=194;aulast=Philip
id doaj-a52b729fc3d24f4b83a6c3c76bd4e9f7
record_format Article
spelling doaj-a52b729fc3d24f4b83a6c3c76bd4e9f72021-01-21T13:11:24ZengWolters Kluwer Medknow PublicationsNational Journal of Clinical Anatomy2277-40252321-27802018-01-017419019410.4103/2277-4025.294771A morphometric study of glenoid cavity and its implication in shoulder arthroplasty and prosthetic designsShalom Elsy PhilipK R DakshayaniBackground and aims: Glenoid cavity of scapula is known for its variable morphology. The variations in the shape of glenoid cavity are due to the presence of a notch in its antero-superior part. The glenoid cavity is small and allows only a limited area for fixation devices. Knowledge of its morphology and dimensions would help in designing shoulder prosthesis for shoulder arthroplasty. Aim of current study is to determine the metrical and morphological variations [variation of shapes] of the glenoid cavity of the scapula for a better understanding and management of shoulder pathology. Materials and Method: One hundred dry scapulae of unknown sex availed from the Department of Anatomy, Mysore Medical College were studied. Varying shape of glenoid cavity based on presence of notch was also noted and measurements were taken with the digital Vernier caliper. Results: The glenoid cavity was found to occur in pear, oval, inverted comma shapes in frequency of 65.3%, 28.8%, 5.7% on right side and 62.2%, 27%, 10% on left side respectively. The mean anteroposterior diameter 1 and 2 were 24.05 ± 2.79 mm and 18.31 ± 2.36mm respectively. The mean Glenoid cavity index was 68.05 ± 4.87mm. Conclusion: The findings of the present study concurs with other studies, although there is slight difference in frequency of occurrence of shape of glenoid cavity which could be explained on the basis of ethnic and racial basis. The sound knowledge of various parameters of the glenoid cavity is important while performing shoulder arthroplasty and designing glenoid prostheseshttp://www.njca.info/article.asp?issn=2277-4025;year=2018;volume=7;issue=4;spage=190;epage=194;aulast=Philipglenoid cavityglenoid prosthesesshoulder arthroplasty
collection DOAJ
language English
format Article
sources DOAJ
author Shalom Elsy Philip
K R Dakshayani
spellingShingle Shalom Elsy Philip
K R Dakshayani
A morphometric study of glenoid cavity and its implication in shoulder arthroplasty and prosthetic designs
National Journal of Clinical Anatomy
glenoid cavity
glenoid prostheses
shoulder arthroplasty
author_facet Shalom Elsy Philip
K R Dakshayani
author_sort Shalom Elsy Philip
title A morphometric study of glenoid cavity and its implication in shoulder arthroplasty and prosthetic designs
title_short A morphometric study of glenoid cavity and its implication in shoulder arthroplasty and prosthetic designs
title_full A morphometric study of glenoid cavity and its implication in shoulder arthroplasty and prosthetic designs
title_fullStr A morphometric study of glenoid cavity and its implication in shoulder arthroplasty and prosthetic designs
title_full_unstemmed A morphometric study of glenoid cavity and its implication in shoulder arthroplasty and prosthetic designs
title_sort morphometric study of glenoid cavity and its implication in shoulder arthroplasty and prosthetic designs
publisher Wolters Kluwer Medknow Publications
series National Journal of Clinical Anatomy
issn 2277-4025
2321-2780
publishDate 2018-01-01
description Background and aims: Glenoid cavity of scapula is known for its variable morphology. The variations in the shape of glenoid cavity are due to the presence of a notch in its antero-superior part. The glenoid cavity is small and allows only a limited area for fixation devices. Knowledge of its morphology and dimensions would help in designing shoulder prosthesis for shoulder arthroplasty. Aim of current study is to determine the metrical and morphological variations [variation of shapes] of the glenoid cavity of the scapula for a better understanding and management of shoulder pathology. Materials and Method: One hundred dry scapulae of unknown sex availed from the Department of Anatomy, Mysore Medical College were studied. Varying shape of glenoid cavity based on presence of notch was also noted and measurements were taken with the digital Vernier caliper. Results: The glenoid cavity was found to occur in pear, oval, inverted comma shapes in frequency of 65.3%, 28.8%, 5.7% on right side and 62.2%, 27%, 10% on left side respectively. The mean anteroposterior diameter 1 and 2 were 24.05 ± 2.79 mm and 18.31 ± 2.36mm respectively. The mean Glenoid cavity index was 68.05 ± 4.87mm. Conclusion: The findings of the present study concurs with other studies, although there is slight difference in frequency of occurrence of shape of glenoid cavity which could be explained on the basis of ethnic and racial basis. The sound knowledge of various parameters of the glenoid cavity is important while performing shoulder arthroplasty and designing glenoid prostheses
topic glenoid cavity
glenoid prostheses
shoulder arthroplasty
url http://www.njca.info/article.asp?issn=2277-4025;year=2018;volume=7;issue=4;spage=190;epage=194;aulast=Philip
work_keys_str_mv AT shalomelsyphilip amorphometricstudyofglenoidcavityanditsimplicationinshoulderarthroplastyandprostheticdesigns
AT krdakshayani amorphometricstudyofglenoidcavityanditsimplicationinshoulderarthroplastyandprostheticdesigns
AT shalomelsyphilip morphometricstudyofglenoidcavityanditsimplicationinshoulderarthroplastyandprostheticdesigns
AT krdakshayani morphometricstudyofglenoidcavityanditsimplicationinshoulderarthroplastyandprostheticdesigns
_version_ 1724329939978682368