An advanced expiratory circuit for the recovery of perfluorocarbon liquid from non-saturated perfluorocarbon vapour during partial liquid ventilation: an experimental model

<p>Abstract</p> <p>Background</p> <p>The loss of perfluorocarbon (PFC) vapour in the expired gases during partial liquid ventilation should be minimized both to prevent perfluorocarbon vapour entering the atmosphere and to re-use the recovered PFC liquid.</p> <...

Full description

Bibliographic Details
Main Authors: Davies Mark W, Dunster Kimble R, Fraser John F
Format: Article
Language:English
Published: BMC 2006-02-01
Series:BioMedical Engineering OnLine
Online Access:http://www.biomedical-engineering-online.com/content/5/1/7
id doaj-a55842ac8a0847398809e96b49b91805
record_format Article
spelling doaj-a55842ac8a0847398809e96b49b918052020-11-24T23:28:07ZengBMCBioMedical Engineering OnLine1475-925X2006-02-0151710.1186/1475-925X-5-7An advanced expiratory circuit for the recovery of perfluorocarbon liquid from non-saturated perfluorocarbon vapour during partial liquid ventilation: an experimental modelDavies Mark WDunster Kimble RFraser John F<p>Abstract</p> <p>Background</p> <p>The loss of perfluorocarbon (PFC) vapour in the expired gases during partial liquid ventilation should be minimized both to prevent perfluorocarbon vapour entering the atmosphere and to re-use the recovered PFC liquid.</p> <p>Using a substantially modified design of our previously described condenser, we aimed to determine how much perfluorocarbon liquid could be recovered from gases containing PFC and water vapour, at concentrations found during partial liquid ventilation, and to determine if the amount recovered differed with background flow rate (at flow rates suitable for use in neonates).</p> <p>Methods</p> <p>The expiratory line of a standard ventilator circuit set-up was mimicked, with the addition of two condensers. Perfluorocarbon (30 mL of FC-77) and water vapour, at concentrations found during partial liquid ventilation, were passed through the circuit at a number of flow rates and the percentage recovery of the liquids measured.</p> <p>Results</p> <p>From 14.2 mL (47%) to 27.3 mL (91%) of the infused 30 mL of FC-77 was recovered at the flow rates studied. Significantly higher FC-77 recovery was obtained at lower flow rates (ANOVA with Bonferroni's multiple comparison test, p < 0.0001). As a percentage of the theoretical maximum recovery, 64 to 95% of the FC-77 was recovered. Statistically significantly less FC-77 was recovered at 5 Lmin<sup>-1 </sup>(ANOVA with Bonferroni's multiple comparison test, p < 0.0001). Amounts of perfluorocarbon vapour recovered were 47%, 50%, 81% and 91% at flow rates of 10, 5, 2 and 1 Lmin<sup>-1</sup>, respectively.</p> <p>Conclusion</p> <p>Using two condensers in series 47% to 91% of perfluorocarbon liquid can be recovered, from gases containing perfluorocarbon and water vapour, at concentrations found during partial liquid ventilation.</p> http://www.biomedical-engineering-online.com/content/5/1/7
collection DOAJ
language English
format Article
sources DOAJ
author Davies Mark W
Dunster Kimble R
Fraser John F
spellingShingle Davies Mark W
Dunster Kimble R
Fraser John F
An advanced expiratory circuit for the recovery of perfluorocarbon liquid from non-saturated perfluorocarbon vapour during partial liquid ventilation: an experimental model
BioMedical Engineering OnLine
author_facet Davies Mark W
Dunster Kimble R
Fraser John F
author_sort Davies Mark W
title An advanced expiratory circuit for the recovery of perfluorocarbon liquid from non-saturated perfluorocarbon vapour during partial liquid ventilation: an experimental model
title_short An advanced expiratory circuit for the recovery of perfluorocarbon liquid from non-saturated perfluorocarbon vapour during partial liquid ventilation: an experimental model
title_full An advanced expiratory circuit for the recovery of perfluorocarbon liquid from non-saturated perfluorocarbon vapour during partial liquid ventilation: an experimental model
title_fullStr An advanced expiratory circuit for the recovery of perfluorocarbon liquid from non-saturated perfluorocarbon vapour during partial liquid ventilation: an experimental model
title_full_unstemmed An advanced expiratory circuit for the recovery of perfluorocarbon liquid from non-saturated perfluorocarbon vapour during partial liquid ventilation: an experimental model
title_sort advanced expiratory circuit for the recovery of perfluorocarbon liquid from non-saturated perfluorocarbon vapour during partial liquid ventilation: an experimental model
publisher BMC
series BioMedical Engineering OnLine
issn 1475-925X
publishDate 2006-02-01
description <p>Abstract</p> <p>Background</p> <p>The loss of perfluorocarbon (PFC) vapour in the expired gases during partial liquid ventilation should be minimized both to prevent perfluorocarbon vapour entering the atmosphere and to re-use the recovered PFC liquid.</p> <p>Using a substantially modified design of our previously described condenser, we aimed to determine how much perfluorocarbon liquid could be recovered from gases containing PFC and water vapour, at concentrations found during partial liquid ventilation, and to determine if the amount recovered differed with background flow rate (at flow rates suitable for use in neonates).</p> <p>Methods</p> <p>The expiratory line of a standard ventilator circuit set-up was mimicked, with the addition of two condensers. Perfluorocarbon (30 mL of FC-77) and water vapour, at concentrations found during partial liquid ventilation, were passed through the circuit at a number of flow rates and the percentage recovery of the liquids measured.</p> <p>Results</p> <p>From 14.2 mL (47%) to 27.3 mL (91%) of the infused 30 mL of FC-77 was recovered at the flow rates studied. Significantly higher FC-77 recovery was obtained at lower flow rates (ANOVA with Bonferroni's multiple comparison test, p < 0.0001). As a percentage of the theoretical maximum recovery, 64 to 95% of the FC-77 was recovered. Statistically significantly less FC-77 was recovered at 5 Lmin<sup>-1 </sup>(ANOVA with Bonferroni's multiple comparison test, p < 0.0001). Amounts of perfluorocarbon vapour recovered were 47%, 50%, 81% and 91% at flow rates of 10, 5, 2 and 1 Lmin<sup>-1</sup>, respectively.</p> <p>Conclusion</p> <p>Using two condensers in series 47% to 91% of perfluorocarbon liquid can be recovered, from gases containing perfluorocarbon and water vapour, at concentrations found during partial liquid ventilation.</p>
url http://www.biomedical-engineering-online.com/content/5/1/7
work_keys_str_mv AT daviesmarkw anadvancedexpiratorycircuitfortherecoveryofperfluorocarbonliquidfromnonsaturatedperfluorocarbonvapourduringpartialliquidventilationanexperimentalmodel
AT dunsterkimbler anadvancedexpiratorycircuitfortherecoveryofperfluorocarbonliquidfromnonsaturatedperfluorocarbonvapourduringpartialliquidventilationanexperimentalmodel
AT fraserjohnf anadvancedexpiratorycircuitfortherecoveryofperfluorocarbonliquidfromnonsaturatedperfluorocarbonvapourduringpartialliquidventilationanexperimentalmodel
AT daviesmarkw advancedexpiratorycircuitfortherecoveryofperfluorocarbonliquidfromnonsaturatedperfluorocarbonvapourduringpartialliquidventilationanexperimentalmodel
AT dunsterkimbler advancedexpiratorycircuitfortherecoveryofperfluorocarbonliquidfromnonsaturatedperfluorocarbonvapourduringpartialliquidventilationanexperimentalmodel
AT fraserjohnf advancedexpiratorycircuitfortherecoveryofperfluorocarbonliquidfromnonsaturatedperfluorocarbonvapourduringpartialliquidventilationanexperimentalmodel
_version_ 1725550575912747008