The Reliability and Validity of Short Form-12 Health Survey Version 2 for Chinese Older Adults

Background: We assessed the information regarding the psychometric properties of the Short Form-12 Health Survey Version 2 (SF-12v2) among older adults in China Methods: A cross-sectional study was conducted on a stratified representative sample of older adults (≥60 years) residing in community...

Full description

Bibliographic Details
Main Authors: Shu-Wen SU, Dong WANG
Format: Article
Language:English
Published: Tehran University of Medical Sciences 2019-06-01
Series:Iranian Journal of Public Health
Subjects:
Online Access:https://ijph.tums.ac.ir/index.php/ijph/article/view/17337
id doaj-a5d30b528db84f37b474733eda9ab133
record_format Article
spelling doaj-a5d30b528db84f37b474733eda9ab1332021-01-02T16:11:24ZengTehran University of Medical SciencesIranian Journal of Public Health2251-60852251-60932019-06-0148610.18502/ijph.v48i6.2898The Reliability and Validity of Short Form-12 Health Survey Version 2 for Chinese Older AdultsShu-Wen SU0Dong WANG1School of Health Services Management, Southern Medical University, 1023 Shatai Road, Guangzhou 510515, ChinaSchool of Health Services Management, Southern Medical University, 1023 Shatai Road, Guangzhou 510515, China Background: We assessed the information regarding the psychometric properties of the Short Form-12 Health Survey Version 2 (SF-12v2) among older adults in China Methods: A cross-sectional study was conducted on a stratified representative sample of older adults (≥60 years) residing in community and nursing home settings in 2017-18. Reliability was estimated using the internal consistency method. Validity was assessed using convergent and discriminant validity checks, factor analyses (including both exploratory and confirmatory factor analyses [EFA and CFA]), and “known groups” construct validity. Results: The final sample comprised 1000 older adults (451 community-dwelling and 549 institutional). Cronbach’s α was 0.81 for the Physical Component Summary (PCS) and 0.83 for the Mental Component Summary (MCS), showing satisfactory internal consistency for both. Most items were strongly correlated with their represented component (Spearman’s correlation coefficient: 0.62–0.87), although the correlation of SF items with PCS was a bit stronger than that with MCS. A two-factor structure (physical and mental health) indicated by EFA jointly accounted for 68.50% of the variance and presented adequate goodness-of-fit indices (GFI=0.98, AGFI=0.92, RMSEA=0.08, 90% Cl RMSEA=0.06 to 0.11, NFI=0.98, and CFI=0.98) in CFA. Known-groups comparison showed that SF-12v2 summary scores did well in differentiating subgroups of older adults by age, marital status, and self-reported health problems (P≤0.05). Conclusion: SF-12v2 is a reliable and valid health-related quality of life instrument for Chinese older adults that works equally well with older adults under institutional care and community-based home care models.     https://ijph.tums.ac.ir/index.php/ijph/article/view/17337Health-related quality of lifeOlder adultsReliabilitySF-12v2Validity
collection DOAJ
language English
format Article
sources DOAJ
author Shu-Wen SU
Dong WANG
spellingShingle Shu-Wen SU
Dong WANG
The Reliability and Validity of Short Form-12 Health Survey Version 2 for Chinese Older Adults
Iranian Journal of Public Health
Health-related quality of life
Older adults
Reliability
SF-12v2
Validity
author_facet Shu-Wen SU
Dong WANG
author_sort Shu-Wen SU
title The Reliability and Validity of Short Form-12 Health Survey Version 2 for Chinese Older Adults
title_short The Reliability and Validity of Short Form-12 Health Survey Version 2 for Chinese Older Adults
title_full The Reliability and Validity of Short Form-12 Health Survey Version 2 for Chinese Older Adults
title_fullStr The Reliability and Validity of Short Form-12 Health Survey Version 2 for Chinese Older Adults
title_full_unstemmed The Reliability and Validity of Short Form-12 Health Survey Version 2 for Chinese Older Adults
title_sort reliability and validity of short form-12 health survey version 2 for chinese older adults
publisher Tehran University of Medical Sciences
series Iranian Journal of Public Health
issn 2251-6085
2251-6093
publishDate 2019-06-01
description Background: We assessed the information regarding the psychometric properties of the Short Form-12 Health Survey Version 2 (SF-12v2) among older adults in China Methods: A cross-sectional study was conducted on a stratified representative sample of older adults (≥60 years) residing in community and nursing home settings in 2017-18. Reliability was estimated using the internal consistency method. Validity was assessed using convergent and discriminant validity checks, factor analyses (including both exploratory and confirmatory factor analyses [EFA and CFA]), and “known groups” construct validity. Results: The final sample comprised 1000 older adults (451 community-dwelling and 549 institutional). Cronbach’s α was 0.81 for the Physical Component Summary (PCS) and 0.83 for the Mental Component Summary (MCS), showing satisfactory internal consistency for both. Most items were strongly correlated with their represented component (Spearman’s correlation coefficient: 0.62–0.87), although the correlation of SF items with PCS was a bit stronger than that with MCS. A two-factor structure (physical and mental health) indicated by EFA jointly accounted for 68.50% of the variance and presented adequate goodness-of-fit indices (GFI=0.98, AGFI=0.92, RMSEA=0.08, 90% Cl RMSEA=0.06 to 0.11, NFI=0.98, and CFI=0.98) in CFA. Known-groups comparison showed that SF-12v2 summary scores did well in differentiating subgroups of older adults by age, marital status, and self-reported health problems (P≤0.05). Conclusion: SF-12v2 is a reliable and valid health-related quality of life instrument for Chinese older adults that works equally well with older adults under institutional care and community-based home care models.    
topic Health-related quality of life
Older adults
Reliability
SF-12v2
Validity
url https://ijph.tums.ac.ir/index.php/ijph/article/view/17337
work_keys_str_mv AT shuwensu thereliabilityandvalidityofshortform12healthsurveyversion2forchineseolderadults
AT dongwang thereliabilityandvalidityofshortform12healthsurveyversion2forchineseolderadults
AT shuwensu reliabilityandvalidityofshortform12healthsurveyversion2forchineseolderadults
AT dongwang reliabilityandvalidityofshortform12healthsurveyversion2forchineseolderadults
_version_ 1724352288761315328