Measurement of central corneal thickness and pre-corneal tear film thickness of rabbits using the Scheimpflug system

<b>AIM:</b>To measure central corneal thickness (CCT) and pre-corneal tear film thickness using the Galilei dual-Scheimpflug analyzer (GSA) in New Zealand white rabbits.<b>METHODS:</b>Ten normal New Zealand white rabbits (20 eyes) were included in this study. With the assista...

Full description

Bibliographic Details
Main Authors: Jing Dong, Qiang Wu, Xiao-Gang Wang
Format: Article
Language:English
Published: Press of International Journal of Ophthalmology (IJO PRESS) 2013-10-01
Series:International Journal of Ophthalmology
Subjects:
Online Access:http://www.ijo.cn/en_publish/2013/5/20130506.pdf
id doaj-a697289aeddd454ebba9116014631664
record_format Article
spelling doaj-a697289aeddd454ebba91160146316642020-11-24T20:56:07ZengPress of International Journal of Ophthalmology (IJO PRESS)International Journal of Ophthalmology2222-39592227-48982013-10-016558458710.3980/j.issn.2222-3959.2013.05.05Measurement of central corneal thickness and pre-corneal tear film thickness of rabbits using the Scheimpflug systemJing DongQiang WuXiao-Gang Wang<b>AIM:</b>To measure central corneal thickness (CCT) and pre-corneal tear film thickness using the Galilei dual-Scheimpflug analyzer (GSA) in New Zealand white rabbits.<b>METHODS:</b>Ten normal New Zealand white rabbits (20 eyes) were included in this study. With the assistance of 0.1% fluorescein, the pre-corneal tear film can be well visualized. Both eyes of each rabbit were scanned once with the GSA pre- and post-instillation of 1μL 0.1% fluorescein. The difference between the two measurements of CCT (4-mm diameter) was recorded as the pachymetric values of the central tear film.<b>RESULTS:</b>The CCT of pre- and post-instillation was 388.8±9.5μm and 407.0±10.5μm, respectively. After a paired <i>t</i>-test analysis, the central pre-corneal tear film thickness of 4mm diameter was 18.2±5.31μm with a 95% confidence interval of (15.7, 20.6)μm (<i>P</i><0.001).<b>CONCLUSION:</b>GSA can be used to measure CCT and analyze central tear film thickness of rabbits with the help of fluorescein.http://www.ijo.cn/en_publish/2013/5/20130506.pdftear filmScheimpflugrabbitscentral corneal thicknessfluorescein
collection DOAJ
language English
format Article
sources DOAJ
author Jing Dong
Qiang Wu
Xiao-Gang Wang
spellingShingle Jing Dong
Qiang Wu
Xiao-Gang Wang
Measurement of central corneal thickness and pre-corneal tear film thickness of rabbits using the Scheimpflug system
International Journal of Ophthalmology
tear film
Scheimpflug
rabbits
central corneal thickness
fluorescein
author_facet Jing Dong
Qiang Wu
Xiao-Gang Wang
author_sort Jing Dong
title Measurement of central corneal thickness and pre-corneal tear film thickness of rabbits using the Scheimpflug system
title_short Measurement of central corneal thickness and pre-corneal tear film thickness of rabbits using the Scheimpflug system
title_full Measurement of central corneal thickness and pre-corneal tear film thickness of rabbits using the Scheimpflug system
title_fullStr Measurement of central corneal thickness and pre-corneal tear film thickness of rabbits using the Scheimpflug system
title_full_unstemmed Measurement of central corneal thickness and pre-corneal tear film thickness of rabbits using the Scheimpflug system
title_sort measurement of central corneal thickness and pre-corneal tear film thickness of rabbits using the scheimpflug system
publisher Press of International Journal of Ophthalmology (IJO PRESS)
series International Journal of Ophthalmology
issn 2222-3959
2227-4898
publishDate 2013-10-01
description <b>AIM:</b>To measure central corneal thickness (CCT) and pre-corneal tear film thickness using the Galilei dual-Scheimpflug analyzer (GSA) in New Zealand white rabbits.<b>METHODS:</b>Ten normal New Zealand white rabbits (20 eyes) were included in this study. With the assistance of 0.1% fluorescein, the pre-corneal tear film can be well visualized. Both eyes of each rabbit were scanned once with the GSA pre- and post-instillation of 1μL 0.1% fluorescein. The difference between the two measurements of CCT (4-mm diameter) was recorded as the pachymetric values of the central tear film.<b>RESULTS:</b>The CCT of pre- and post-instillation was 388.8±9.5μm and 407.0±10.5μm, respectively. After a paired <i>t</i>-test analysis, the central pre-corneal tear film thickness of 4mm diameter was 18.2±5.31μm with a 95% confidence interval of (15.7, 20.6)μm (<i>P</i><0.001).<b>CONCLUSION:</b>GSA can be used to measure CCT and analyze central tear film thickness of rabbits with the help of fluorescein.
topic tear film
Scheimpflug
rabbits
central corneal thickness
fluorescein
url http://www.ijo.cn/en_publish/2013/5/20130506.pdf
work_keys_str_mv AT jingdong measurementofcentralcornealthicknessandprecornealtearfilmthicknessofrabbitsusingthescheimpflugsystem
AT qiangwu measurementofcentralcornealthicknessandprecornealtearfilmthicknessofrabbitsusingthescheimpflugsystem
AT xiaogangwang measurementofcentralcornealthicknessandprecornealtearfilmthicknessofrabbitsusingthescheimpflugsystem
_version_ 1716790729650470912