Clinical utility of anterior segment optical coherence tomography in strabismus surgery: Prospective observational study

Aim: The aim of this study is to evaluate the accuracy of the anterior segment optical coherence tomography (AS-OCT) in measuring the distance from the limbus to the insertion of primary and previously operated horizontal rectus muscles. Materials and Methods: This was prospective observational stud...

Full description

Bibliographic Details
Main Authors: Joseph John, Elizabeth K Joseph, C K Meena, Sanitha Sathyan
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2017-01-01
Series:Kerala Journal of Ophthalmology
Subjects:
Online Access:http://www.kjophthal.com/article.asp?issn=0976-6677;year=2017;volume=29;issue=2;spage=112;epage=115;aulast=John
id doaj-a8a85abd04f74039a30f866dd19dfcf1
record_format Article
spelling doaj-a8a85abd04f74039a30f866dd19dfcf12020-11-25T00:03:22ZengWolters Kluwer Medknow PublicationsKerala Journal of Ophthalmology0976-66772017-01-0129211211510.4103/kjo.kjo_32_17Clinical utility of anterior segment optical coherence tomography in strabismus surgery: Prospective observational studyJoseph JohnElizabeth K JosephC K MeenaSanitha SathyanAim: The aim of this study is to evaluate the accuracy of the anterior segment optical coherence tomography (AS-OCT) in measuring the distance from the limbus to the insertion of primary and previously operated horizontal rectus muscles. Materials and Methods: This was prospective observational study; we did AS-OCT preoperatively and measured the distance from angle of anterior chamber to muscle insertion using the caliper tool provided in the software. We calculated limbus-insertion distance by adding 1 mm to the angle-insertion distance. We compared this value with intraoperative measurement obtained with surgical caliper. Results: Totally 35 muscles were evaluated, including 12 previously operated muscles. 88.6% of the measurements were within the 1 mm difference considered clinically acceptable. Bland– Altman plots showed good agreement between the two methods. Conclusions: AS-OCT can image the horizontal rectus muscle insertions well and provide good reliability and accuracy in measurement of the limbus-insertion distance.http://www.kjophthal.com/article.asp?issn=0976-6677;year=2017;volume=29;issue=2;spage=112;epage=115;aulast=JohnAnterior segment optical coherence tomographycaliperstrabismus
collection DOAJ
language English
format Article
sources DOAJ
author Joseph John
Elizabeth K Joseph
C K Meena
Sanitha Sathyan
spellingShingle Joseph John
Elizabeth K Joseph
C K Meena
Sanitha Sathyan
Clinical utility of anterior segment optical coherence tomography in strabismus surgery: Prospective observational study
Kerala Journal of Ophthalmology
Anterior segment optical coherence tomography
caliper
strabismus
author_facet Joseph John
Elizabeth K Joseph
C K Meena
Sanitha Sathyan
author_sort Joseph John
title Clinical utility of anterior segment optical coherence tomography in strabismus surgery: Prospective observational study
title_short Clinical utility of anterior segment optical coherence tomography in strabismus surgery: Prospective observational study
title_full Clinical utility of anterior segment optical coherence tomography in strabismus surgery: Prospective observational study
title_fullStr Clinical utility of anterior segment optical coherence tomography in strabismus surgery: Prospective observational study
title_full_unstemmed Clinical utility of anterior segment optical coherence tomography in strabismus surgery: Prospective observational study
title_sort clinical utility of anterior segment optical coherence tomography in strabismus surgery: prospective observational study
publisher Wolters Kluwer Medknow Publications
series Kerala Journal of Ophthalmology
issn 0976-6677
publishDate 2017-01-01
description Aim: The aim of this study is to evaluate the accuracy of the anterior segment optical coherence tomography (AS-OCT) in measuring the distance from the limbus to the insertion of primary and previously operated horizontal rectus muscles. Materials and Methods: This was prospective observational study; we did AS-OCT preoperatively and measured the distance from angle of anterior chamber to muscle insertion using the caliper tool provided in the software. We calculated limbus-insertion distance by adding 1 mm to the angle-insertion distance. We compared this value with intraoperative measurement obtained with surgical caliper. Results: Totally 35 muscles were evaluated, including 12 previously operated muscles. 88.6% of the measurements were within the 1 mm difference considered clinically acceptable. Bland– Altman plots showed good agreement between the two methods. Conclusions: AS-OCT can image the horizontal rectus muscle insertions well and provide good reliability and accuracy in measurement of the limbus-insertion distance.
topic Anterior segment optical coherence tomography
caliper
strabismus
url http://www.kjophthal.com/article.asp?issn=0976-6677;year=2017;volume=29;issue=2;spage=112;epage=115;aulast=John
work_keys_str_mv AT josephjohn clinicalutilityofanteriorsegmentopticalcoherencetomographyinstrabismussurgeryprospectiveobservationalstudy
AT elizabethkjoseph clinicalutilityofanteriorsegmentopticalcoherencetomographyinstrabismussurgeryprospectiveobservationalstudy
AT ckmeena clinicalutilityofanteriorsegmentopticalcoherencetomographyinstrabismussurgeryprospectiveobservationalstudy
AT sanithasathyan clinicalutilityofanteriorsegmentopticalcoherencetomographyinstrabismussurgeryprospectiveobservationalstudy
_version_ 1725434419152420864