Clinical utility of anterior segment optical coherence tomography in strabismus surgery: Prospective observational study
Aim: The aim of this study is to evaluate the accuracy of the anterior segment optical coherence tomography (AS-OCT) in measuring the distance from the limbus to the insertion of primary and previously operated horizontal rectus muscles. Materials and Methods: This was prospective observational stud...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wolters Kluwer Medknow Publications
2017-01-01
|
Series: | Kerala Journal of Ophthalmology |
Subjects: | |
Online Access: | http://www.kjophthal.com/article.asp?issn=0976-6677;year=2017;volume=29;issue=2;spage=112;epage=115;aulast=John |
id |
doaj-a8a85abd04f74039a30f866dd19dfcf1 |
---|---|
record_format |
Article |
spelling |
doaj-a8a85abd04f74039a30f866dd19dfcf12020-11-25T00:03:22ZengWolters Kluwer Medknow PublicationsKerala Journal of Ophthalmology0976-66772017-01-0129211211510.4103/kjo.kjo_32_17Clinical utility of anterior segment optical coherence tomography in strabismus surgery: Prospective observational studyJoseph JohnElizabeth K JosephC K MeenaSanitha SathyanAim: The aim of this study is to evaluate the accuracy of the anterior segment optical coherence tomography (AS-OCT) in measuring the distance from the limbus to the insertion of primary and previously operated horizontal rectus muscles. Materials and Methods: This was prospective observational study; we did AS-OCT preoperatively and measured the distance from angle of anterior chamber to muscle insertion using the caliper tool provided in the software. We calculated limbus-insertion distance by adding 1 mm to the angle-insertion distance. We compared this value with intraoperative measurement obtained with surgical caliper. Results: Totally 35 muscles were evaluated, including 12 previously operated muscles. 88.6% of the measurements were within the 1 mm difference considered clinically acceptable. Bland– Altman plots showed good agreement between the two methods. Conclusions: AS-OCT can image the horizontal rectus muscle insertions well and provide good reliability and accuracy in measurement of the limbus-insertion distance.http://www.kjophthal.com/article.asp?issn=0976-6677;year=2017;volume=29;issue=2;spage=112;epage=115;aulast=JohnAnterior segment optical coherence tomographycaliperstrabismus |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Joseph John Elizabeth K Joseph C K Meena Sanitha Sathyan |
spellingShingle |
Joseph John Elizabeth K Joseph C K Meena Sanitha Sathyan Clinical utility of anterior segment optical coherence tomography in strabismus surgery: Prospective observational study Kerala Journal of Ophthalmology Anterior segment optical coherence tomography caliper strabismus |
author_facet |
Joseph John Elizabeth K Joseph C K Meena Sanitha Sathyan |
author_sort |
Joseph John |
title |
Clinical utility of anterior segment optical coherence tomography in strabismus surgery: Prospective observational study |
title_short |
Clinical utility of anterior segment optical coherence tomography in strabismus surgery: Prospective observational study |
title_full |
Clinical utility of anterior segment optical coherence tomography in strabismus surgery: Prospective observational study |
title_fullStr |
Clinical utility of anterior segment optical coherence tomography in strabismus surgery: Prospective observational study |
title_full_unstemmed |
Clinical utility of anterior segment optical coherence tomography in strabismus surgery: Prospective observational study |
title_sort |
clinical utility of anterior segment optical coherence tomography in strabismus surgery: prospective observational study |
publisher |
Wolters Kluwer Medknow Publications |
series |
Kerala Journal of Ophthalmology |
issn |
0976-6677 |
publishDate |
2017-01-01 |
description |
Aim: The aim of this study is to evaluate the accuracy of the anterior segment optical coherence tomography (AS-OCT) in measuring the distance from the limbus to the insertion of primary and previously operated horizontal rectus muscles.
Materials and Methods: This was prospective observational study; we did AS-OCT preoperatively and measured the distance from angle of anterior chamber to muscle insertion using the caliper tool provided in the software. We calculated limbus-insertion distance by adding 1 mm to the angle-insertion distance. We compared this value with intraoperative measurement obtained with surgical caliper.
Results: Totally 35 muscles were evaluated, including 12 previously operated muscles. 88.6% of the measurements were within the 1 mm difference considered clinically acceptable. Bland– Altman plots showed good agreement between the two methods.
Conclusions: AS-OCT can image the horizontal rectus muscle insertions well and provide good reliability and accuracy in measurement of the limbus-insertion distance. |
topic |
Anterior segment optical coherence tomography caliper strabismus |
url |
http://www.kjophthal.com/article.asp?issn=0976-6677;year=2017;volume=29;issue=2;spage=112;epage=115;aulast=John |
work_keys_str_mv |
AT josephjohn clinicalutilityofanteriorsegmentopticalcoherencetomographyinstrabismussurgeryprospectiveobservationalstudy AT elizabethkjoseph clinicalutilityofanteriorsegmentopticalcoherencetomographyinstrabismussurgeryprospectiveobservationalstudy AT ckmeena clinicalutilityofanteriorsegmentopticalcoherencetomographyinstrabismussurgeryprospectiveobservationalstudy AT sanithasathyan clinicalutilityofanteriorsegmentopticalcoherencetomographyinstrabismussurgeryprospectiveobservationalstudy |
_version_ |
1725434419152420864 |