Experimental Study on the Influencing Factors of Treatment of Landfill Sludge Using Vacuum Preloading with the Fenton Reagent

At present, there is a lack of necessary technical parameters for sludge vacuum reinforcement. To explore the effects of the drain board type on sludge vacuum reinforcement, the Fenton reagent was used to pretreat the landfill sludge in a sludge landfill area in Shanghai, and then, vacuum preloading...

Full description

Bibliographic Details
Main Authors: Yajun Wu, Binjie Song, Yitian Lu, Qingyang Deng, Guang Chen
Format: Article
Language:English
Published: Hindawi-Wiley 2021-01-01
Series:Geofluids
Online Access:http://dx.doi.org/10.1155/2021/9962141
id doaj-a92ccf90f5ec49998a3247057f97b866
record_format Article
spelling doaj-a92ccf90f5ec49998a3247057f97b8662021-06-28T01:51:10ZengHindawi-WileyGeofluids1468-81232021-01-01202110.1155/2021/9962141Experimental Study on the Influencing Factors of Treatment of Landfill Sludge Using Vacuum Preloading with the Fenton ReagentYajun Wu0Binjie Song1Yitian Lu2Qingyang Deng3Guang Chen4Department of Civil EngineeringDepartment of Civil EngineeringDepartment of Civil EngineeringShanghai Urban Operation (Group) Co.Shanghai Chengtou Wastewater Treatment Co. Ltd.At present, there is a lack of necessary technical parameters for sludge vacuum reinforcement. To explore the effects of the drain board type on sludge vacuum reinforcement, the Fenton reagent was used to pretreat the landfill sludge in a sludge landfill area in Shanghai, and then, vacuum preloading contrast tests of different prefabricated vertical drainage types were carried out. During the test, the discharge and settlement of sludge were recorded. After the test, the moisture content, shear strength, and appearance of PVD were measured and analysed. The main conclusions are as follows: (1) the optimum ratio of H2O2 and Fe2+ is 2 for the landfill sludge; (2) the total displacement and accumulated settlement of the test group with integral prefabricated vertical drainage are 1.7 times and 1.2 times those of the separate prefabricated vertical drainage, respectively; (3) the type of prefabricated vertical drainage has no effect on the distribution of water content and shear strength; and (4) when the sludge is vacuum strengthened, the integral prefabricated vertical drainage should be preferred.http://dx.doi.org/10.1155/2021/9962141
collection DOAJ
language English
format Article
sources DOAJ
author Yajun Wu
Binjie Song
Yitian Lu
Qingyang Deng
Guang Chen
spellingShingle Yajun Wu
Binjie Song
Yitian Lu
Qingyang Deng
Guang Chen
Experimental Study on the Influencing Factors of Treatment of Landfill Sludge Using Vacuum Preloading with the Fenton Reagent
Geofluids
author_facet Yajun Wu
Binjie Song
Yitian Lu
Qingyang Deng
Guang Chen
author_sort Yajun Wu
title Experimental Study on the Influencing Factors of Treatment of Landfill Sludge Using Vacuum Preloading with the Fenton Reagent
title_short Experimental Study on the Influencing Factors of Treatment of Landfill Sludge Using Vacuum Preloading with the Fenton Reagent
title_full Experimental Study on the Influencing Factors of Treatment of Landfill Sludge Using Vacuum Preloading with the Fenton Reagent
title_fullStr Experimental Study on the Influencing Factors of Treatment of Landfill Sludge Using Vacuum Preloading with the Fenton Reagent
title_full_unstemmed Experimental Study on the Influencing Factors of Treatment of Landfill Sludge Using Vacuum Preloading with the Fenton Reagent
title_sort experimental study on the influencing factors of treatment of landfill sludge using vacuum preloading with the fenton reagent
publisher Hindawi-Wiley
series Geofluids
issn 1468-8123
publishDate 2021-01-01
description At present, there is a lack of necessary technical parameters for sludge vacuum reinforcement. To explore the effects of the drain board type on sludge vacuum reinforcement, the Fenton reagent was used to pretreat the landfill sludge in a sludge landfill area in Shanghai, and then, vacuum preloading contrast tests of different prefabricated vertical drainage types were carried out. During the test, the discharge and settlement of sludge were recorded. After the test, the moisture content, shear strength, and appearance of PVD were measured and analysed. The main conclusions are as follows: (1) the optimum ratio of H2O2 and Fe2+ is 2 for the landfill sludge; (2) the total displacement and accumulated settlement of the test group with integral prefabricated vertical drainage are 1.7 times and 1.2 times those of the separate prefabricated vertical drainage, respectively; (3) the type of prefabricated vertical drainage has no effect on the distribution of water content and shear strength; and (4) when the sludge is vacuum strengthened, the integral prefabricated vertical drainage should be preferred.
url http://dx.doi.org/10.1155/2021/9962141
work_keys_str_mv AT yajunwu experimentalstudyontheinfluencingfactorsoftreatmentoflandfillsludgeusingvacuumpreloadingwiththefentonreagent
AT binjiesong experimentalstudyontheinfluencingfactorsoftreatmentoflandfillsludgeusingvacuumpreloadingwiththefentonreagent
AT yitianlu experimentalstudyontheinfluencingfactorsoftreatmentoflandfillsludgeusingvacuumpreloadingwiththefentonreagent
AT qingyangdeng experimentalstudyontheinfluencingfactorsoftreatmentoflandfillsludgeusingvacuumpreloadingwiththefentonreagent
AT guangchen experimentalstudyontheinfluencingfactorsoftreatmentoflandfillsludgeusingvacuumpreloadingwiththefentonreagent
_version_ 1721357216014925824