nsuring the safety and energy efficiency of ventilation of shafts and mines that use the air recycling system

The paper describes the possible failures in the automation ventilation system with partial return use of upcast air from a shaft or mine (during recirculation). Existing ventilation systems use recirculation in the main ventilation mining, through which air is delivered from an underground mining...

Full description

Bibliographic Details
Main Authors: Aleksandr V. Nikolaev, Nikolaj I. Alymenko, Mikhail Chekhlar, Yurai Janocko, Daniil N. Alymenko, Viktor A. Nikolaev
Format: Article
Language:English
Published: Perm National Research Polytechnic University 2017-12-01
Series:Perm Journal of Petroleum and Mining Engineering
Subjects:
Online Access:http://vestnik.pstu.ru/get/_res/fs/file2.pdf/7031/Ensuring+the+safety+and+energy+efficiency+of+ventilation+of+shafts+and+mines+that+use+the+air+recycling+systemfile2.pdf
id doaj-a95cefe351134973ac21ded13c6a434b
record_format Article
spelling doaj-a95cefe351134973ac21ded13c6a434b2020-11-25T02:32:04ZengPerm National Research Polytechnic UniversityPerm Journal of Petroleum and Mining Engineering2224-99232305-11402017-12-0116437037710.15593/2224-9923/2017.4.8nsuring the safety and energy efficiency of ventilation of shafts and mines that use the air recycling systemAleksandr V. Nikolaev0Nikolaj I. Alymenko1Mikhail Chekhlar2Yurai Janocko3Daniil N. Alymenko4Viktor A. Nikolaev5Perm National Research Polytechnic UniversityMining Institute of the Ural Branch of the Russian Academy of SciencesTechnical University of KosiceTechnical University of KosiceUral Research and Development Institute of halurgy JSCPerm National Research Polytechnic University The paper describes the possible failures in the automation ventilation system with partial return use of upcast air from a shaft or mine (during recirculation). Existing ventilation systems use recirculation in the main ventilation mining, through which air is delivered from an underground mining enterprise. It is proposed to install automatic ventilation doors (AVD). They allow to change the aerodynamic resistance of the mine, i.e. control flow rate of air discharged from a mine (shaft). If an AVD is damaged the dangerous case could arise even in a normal ventilation mode due to the fact that mentioned negative control means can block the main path of air movement. In this case air from the air-supplying barrels is directed to the ventilation barrel through the recirculation loop bypassing the mining sites dedicated for ventilation. At the time of accident, when the main fan unit (MFU) is reversed, such a failure makes the situation even more dangerous due to the unpredictable path of flue gases. In the method described it is proposed to install the AVD in the mines of the main directions and close them only during the period of the MFU reverse. When the closing AVD and forced draft fan of the main air heater work together and discharge air in the reverse mode, the time dedicated for switching of the main heater to the reverse mode is reduced. After the gradual opening of the AVD in the shaft (mine) a reversible mode of ventilation is installed. The method proposed allows energy and resource savings for ventilation and air preparation both in normal and emergency modes while meeting the safety requirements for mining operations.http://vestnik.pstu.ru/get/_res/fs/file2.pdf/7031/Ensuring+the+safety+and+energy+efficiency+of+ventilation+of+shafts+and+mines+that+use+the+air+recycling+systemfile2.pdfrecirculationmain ventilation unitair stream reversemining safetyenergy saving
collection DOAJ
language English
format Article
sources DOAJ
author Aleksandr V. Nikolaev
Nikolaj I. Alymenko
Mikhail Chekhlar
Yurai Janocko
Daniil N. Alymenko
Viktor A. Nikolaev
spellingShingle Aleksandr V. Nikolaev
Nikolaj I. Alymenko
Mikhail Chekhlar
Yurai Janocko
Daniil N. Alymenko
Viktor A. Nikolaev
nsuring the safety and energy efficiency of ventilation of shafts and mines that use the air recycling system
Perm Journal of Petroleum and Mining Engineering
recirculation
main ventilation unit
air stream reverse
mining safety
energy saving
author_facet Aleksandr V. Nikolaev
Nikolaj I. Alymenko
Mikhail Chekhlar
Yurai Janocko
Daniil N. Alymenko
Viktor A. Nikolaev
author_sort Aleksandr V. Nikolaev
title nsuring the safety and energy efficiency of ventilation of shafts and mines that use the air recycling system
title_short nsuring the safety and energy efficiency of ventilation of shafts and mines that use the air recycling system
title_full nsuring the safety and energy efficiency of ventilation of shafts and mines that use the air recycling system
title_fullStr nsuring the safety and energy efficiency of ventilation of shafts and mines that use the air recycling system
title_full_unstemmed nsuring the safety and energy efficiency of ventilation of shafts and mines that use the air recycling system
title_sort nsuring the safety and energy efficiency of ventilation of shafts and mines that use the air recycling system
publisher Perm National Research Polytechnic University
series Perm Journal of Petroleum and Mining Engineering
issn 2224-9923
2305-1140
publishDate 2017-12-01
description The paper describes the possible failures in the automation ventilation system with partial return use of upcast air from a shaft or mine (during recirculation). Existing ventilation systems use recirculation in the main ventilation mining, through which air is delivered from an underground mining enterprise. It is proposed to install automatic ventilation doors (AVD). They allow to change the aerodynamic resistance of the mine, i.e. control flow rate of air discharged from a mine (shaft). If an AVD is damaged the dangerous case could arise even in a normal ventilation mode due to the fact that mentioned negative control means can block the main path of air movement. In this case air from the air-supplying barrels is directed to the ventilation barrel through the recirculation loop bypassing the mining sites dedicated for ventilation. At the time of accident, when the main fan unit (MFU) is reversed, such a failure makes the situation even more dangerous due to the unpredictable path of flue gases. In the method described it is proposed to install the AVD in the mines of the main directions and close them only during the period of the MFU reverse. When the closing AVD and forced draft fan of the main air heater work together and discharge air in the reverse mode, the time dedicated for switching of the main heater to the reverse mode is reduced. After the gradual opening of the AVD in the shaft (mine) a reversible mode of ventilation is installed. The method proposed allows energy and resource savings for ventilation and air preparation both in normal and emergency modes while meeting the safety requirements for mining operations.
topic recirculation
main ventilation unit
air stream reverse
mining safety
energy saving
url http://vestnik.pstu.ru/get/_res/fs/file2.pdf/7031/Ensuring+the+safety+and+energy+efficiency+of+ventilation+of+shafts+and+mines+that+use+the+air+recycling+systemfile2.pdf
work_keys_str_mv AT aleksandrvnikolaev nsuringthesafetyandenergyefficiencyofventilationofshaftsandminesthatusetheairrecyclingsystem
AT nikolajialymenko nsuringthesafetyandenergyefficiencyofventilationofshaftsandminesthatusetheairrecyclingsystem
AT mikhailchekhlar nsuringthesafetyandenergyefficiencyofventilationofshaftsandminesthatusetheairrecyclingsystem
AT yuraijanocko nsuringthesafetyandenergyefficiencyofventilationofshaftsandminesthatusetheairrecyclingsystem
AT daniilnalymenko nsuringthesafetyandenergyefficiencyofventilationofshaftsandminesthatusetheairrecyclingsystem
AT viktoranikolaev nsuringthesafetyandenergyefficiencyofventilationofshaftsandminesthatusetheairrecyclingsystem
_version_ 1724821722810548224