Evaluation of Corona Loss in 750 kV Four-Circuit Transmission Lines on the Same Tower Considering Complex Meteorological Conditions

As an important index for measuring the operational economy of EHV AC transmission lines, corona loss (CL) is one of important factors worth considering during the operation and design of transmission lines. The 750-kV transmission lines are mainly distributed in high-altitude areas in northwestern...

Full description

Bibliographic Details
Main Authors: Yunpeng Liu, Sijia Chen, Shilong Huang
Format: Article
Language:English
Published: IEEE 2018-01-01
Series:IEEE Access
Subjects:
Online Access:https://ieeexplore.ieee.org/document/8515208/
id doaj-a9aa0d9711344509a43270c84129a199
record_format Article
spelling doaj-a9aa0d9711344509a43270c84129a1992021-03-29T20:28:56ZengIEEEIEEE Access2169-35362018-01-016674276743310.1109/ACCESS.2018.28787638515208Evaluation of Corona Loss in 750 kV Four-Circuit Transmission Lines on the Same Tower Considering Complex Meteorological ConditionsYunpeng Liu0Sijia Chen1https://orcid.org/0000-0002-4519-7658Shilong Huang2https://orcid.org/0000-0002-4123-6672Hebei Provincial Key Laboratory of Power Equipment Security Defense, North China Electric Power University, Baoding, ChinaHebei Provincial Key Laboratory of Power Equipment Security Defense, North China Electric Power University, Baoding, ChinaHebei Provincial Key Laboratory of Power Equipment Security Defense, North China Electric Power University, Baoding, ChinaAs an important index for measuring the operational economy of EHV AC transmission lines, corona loss (CL) is one of important factors worth considering during the operation and design of transmission lines. The 750-kV transmission lines are mainly distributed in high-altitude areas in northwestern China, where sand storm occurs frequently in spring and autumn. At present, a few researches are available on the evaluation of CL in multi-circuit transmission lines on the same tower in sandy and dusty area at high altitudes. Based on a transmission project with four-circuit transmission lines on the same tower in the north of Xi’an, Shaanxi Province, China, the electric field distributions of bundle conductors under two types of arrangement structure, including six and four cross-arms tower, were investigated. Then, by using the CL equivalent theory, the CL under meteorological conditions of fair, rainy, snowy, foggy, and dusty weather were evaluated. Finally, the optimal phase-sequence arrangement under the optimal tower modes was proposed, and the CL and resistance loss under the selected arrangements were compared.https://ieeexplore.ieee.org/document/8515208/orona losssand and dust weathercorona loss equivalent theory750 kV four-circuit transmission lines on the same towerhigh – altitude area
collection DOAJ
language English
format Article
sources DOAJ
author Yunpeng Liu
Sijia Chen
Shilong Huang
spellingShingle Yunpeng Liu
Sijia Chen
Shilong Huang
Evaluation of Corona Loss in 750 kV Four-Circuit Transmission Lines on the Same Tower Considering Complex Meteorological Conditions
IEEE Access
orona loss
sand and dust weather
corona loss equivalent theory
750 kV four-circuit transmission lines on the same tower
high – altitude area
author_facet Yunpeng Liu
Sijia Chen
Shilong Huang
author_sort Yunpeng Liu
title Evaluation of Corona Loss in 750 kV Four-Circuit Transmission Lines on the Same Tower Considering Complex Meteorological Conditions
title_short Evaluation of Corona Loss in 750 kV Four-Circuit Transmission Lines on the Same Tower Considering Complex Meteorological Conditions
title_full Evaluation of Corona Loss in 750 kV Four-Circuit Transmission Lines on the Same Tower Considering Complex Meteorological Conditions
title_fullStr Evaluation of Corona Loss in 750 kV Four-Circuit Transmission Lines on the Same Tower Considering Complex Meteorological Conditions
title_full_unstemmed Evaluation of Corona Loss in 750 kV Four-Circuit Transmission Lines on the Same Tower Considering Complex Meteorological Conditions
title_sort evaluation of corona loss in 750 kv four-circuit transmission lines on the same tower considering complex meteorological conditions
publisher IEEE
series IEEE Access
issn 2169-3536
publishDate 2018-01-01
description As an important index for measuring the operational economy of EHV AC transmission lines, corona loss (CL) is one of important factors worth considering during the operation and design of transmission lines. The 750-kV transmission lines are mainly distributed in high-altitude areas in northwestern China, where sand storm occurs frequently in spring and autumn. At present, a few researches are available on the evaluation of CL in multi-circuit transmission lines on the same tower in sandy and dusty area at high altitudes. Based on a transmission project with four-circuit transmission lines on the same tower in the north of Xi’an, Shaanxi Province, China, the electric field distributions of bundle conductors under two types of arrangement structure, including six and four cross-arms tower, were investigated. Then, by using the CL equivalent theory, the CL under meteorological conditions of fair, rainy, snowy, foggy, and dusty weather were evaluated. Finally, the optimal phase-sequence arrangement under the optimal tower modes was proposed, and the CL and resistance loss under the selected arrangements were compared.
topic orona loss
sand and dust weather
corona loss equivalent theory
750 kV four-circuit transmission lines on the same tower
high – altitude area
url https://ieeexplore.ieee.org/document/8515208/
work_keys_str_mv AT yunpengliu evaluationofcoronalossin750kvfourcircuittransmissionlinesonthesametowerconsideringcomplexmeteorologicalconditions
AT sijiachen evaluationofcoronalossin750kvfourcircuittransmissionlinesonthesametowerconsideringcomplexmeteorologicalconditions
AT shilonghuang evaluationofcoronalossin750kvfourcircuittransmissionlinesonthesametowerconsideringcomplexmeteorologicalconditions
_version_ 1724194812793454592