Robotically assisted enhanced-view totally extraperitoneal repair (eTEP) of a recurrent umbilical hernia in a patient with peritoneal dialysis

Background: Abdominal wall hernias are frequent in patients with peritoneal dialysis. Guidelines recommend an open hernia repair with extraperitoneal mesh placement to avoid access to the abdominal cavity. Method: We performed a lateral docking robotically assisted enhanced-view totally extraperiton...

Full description

Bibliographic Details
Main Authors: Bauer, Katrin, Heinzelmann, Frank, Vogel, Robert, Büchler, Peter, Mück, Björn
Format: Article
Language:deu
Published: German Medical Science GMS Publishing House 2021-06-01
Series:GMS Interdisciplinary Plastic and Reconstructive Surgery DGPW
Subjects:
Online Access:http://www.egms.de/static/en/journals/iprs/2021-10/iprs000158.shtml