Spherulitic copper–copper oxide nanostructure-based highly sensitive nonenzymatic glucose sensor

Gautam Das, Thao Quynh Ngan Tran, Hyon Hee Yoon Department of Chemical and Biological Engineering, Gachon University, Seongnam, Republic of South Korea Abstract: In this work, three different spherulitic nanostructures Cu–CuOA, Cu–CuOB, and Cu–CuOC were synthesized in...

Full description

Bibliographic Details
Main Authors: Das G, Tran TQN, Yoon HH
Format: Article
Language:English
Published: Dove Medical Press 2015-08-01
Series:International Journal of Nanomedicine
Online Access:http://www.dovepress.com/spherulitic-copperndashcopper-oxide-nanostructure-based-highly-sensiti-peer-reviewed-article-IJN
id doaj-aa52a4dfa58c485c99c109cf703e323e
record_format Article
spelling doaj-aa52a4dfa58c485c99c109cf703e323e2020-11-24T22:08:12ZengDove Medical PressInternational Journal of Nanomedicine1178-20132015-08-012015Special Issue on diverse applications in Nano-Theranostics16517823386Spherulitic copper–copper oxide nanostructure-based highly sensitive nonenzymatic glucose sensorDas GTran TQNYoon HHGautam Das, Thao Quynh Ngan Tran, Hyon Hee Yoon Department of Chemical and Biological Engineering, Gachon University, Seongnam, Republic of South Korea Abstract: In this work, three different spherulitic nanostructures Cu–CuOA, Cu–CuOB, and Cu–CuOC were synthesized in water-in-oil microemulsions by varying the surfactant concentration (30 mM, 40 mM, and 50 mM, respectively). The structural and morphological characteristics of the Cu–CuO nanostructures were investigated by ultraviolet–visible (UV–vis) spectroscopy, X-ray diffraction, scanning electron microscopy, and high-resolution transmission electron microscopy techniques. The synthesized nanostructures were deposited on multiwalled carbon nanotube (MWCNT)-modified indium tin oxide (ITO) electrodes to fabricate a nonenzymatic highly sensitive amperometric glucose sensor. The performance of the ITO/MWCNT/Cu–CuO electrodes in the glucose assay was examined by cyclic voltammetry and chronoamperometric studies. The sensitivity of the sensor varied with the spherulite type; Cu–CuOA, Cu–CuOB, and Cu–CuOC exhibited a sensitivity of 1,229, 3,012, and 3,642 µA mM-1·cm-2, respectively. Moreover, the linear range is dependent on the structure types: 0.023–0.29 mM, 0.07–0.8 mM, and 0.023–0.34 mM for Cu–CuOA, Cu–CuOB, and Cu–CuOC, respectively. An excellent response time of 3 seconds and a low detection limit of 2 µM were observed for Cu–CuOB at an applied potential of +0.34 V. In addition, this electrode was found to be resistant to interference by common interfering agents such as urea, cystamine, l-ascorbic acid, and creatinine. The high performance of the Cu–CuO spherulites with nanowire-to-nanorod outgrowths was primarily due to the high surface area and stability, and good three-dimensional structure. Furthermore, the ITO/MWCNT/Cu–CuOB electrode applied to real urine and serum sample showed satisfactory performance. Keywords: copper oxide, multiwalled carbon nanotubes, glucose sensor, cyclic voltammetryhttp://www.dovepress.com/spherulitic-copperndashcopper-oxide-nanostructure-based-highly-sensiti-peer-reviewed-article-IJN
collection DOAJ
language English
format Article
sources DOAJ
author Das G
Tran TQN
Yoon HH
spellingShingle Das G
Tran TQN
Yoon HH
Spherulitic copper–copper oxide nanostructure-based highly sensitive nonenzymatic glucose sensor
International Journal of Nanomedicine
author_facet Das G
Tran TQN
Yoon HH
author_sort Das G
title Spherulitic copper–copper oxide nanostructure-based highly sensitive nonenzymatic glucose sensor
title_short Spherulitic copper–copper oxide nanostructure-based highly sensitive nonenzymatic glucose sensor
title_full Spherulitic copper–copper oxide nanostructure-based highly sensitive nonenzymatic glucose sensor
title_fullStr Spherulitic copper–copper oxide nanostructure-based highly sensitive nonenzymatic glucose sensor
title_full_unstemmed Spherulitic copper–copper oxide nanostructure-based highly sensitive nonenzymatic glucose sensor
title_sort spherulitic copper–copper oxide nanostructure-based highly sensitive nonenzymatic glucose sensor
publisher Dove Medical Press
series International Journal of Nanomedicine
issn 1178-2013
publishDate 2015-08-01
description Gautam Das, Thao Quynh Ngan Tran, Hyon Hee Yoon Department of Chemical and Biological Engineering, Gachon University, Seongnam, Republic of South Korea Abstract: In this work, three different spherulitic nanostructures Cu–CuOA, Cu–CuOB, and Cu–CuOC were synthesized in water-in-oil microemulsions by varying the surfactant concentration (30 mM, 40 mM, and 50 mM, respectively). The structural and morphological characteristics of the Cu–CuO nanostructures were investigated by ultraviolet–visible (UV–vis) spectroscopy, X-ray diffraction, scanning electron microscopy, and high-resolution transmission electron microscopy techniques. The synthesized nanostructures were deposited on multiwalled carbon nanotube (MWCNT)-modified indium tin oxide (ITO) electrodes to fabricate a nonenzymatic highly sensitive amperometric glucose sensor. The performance of the ITO/MWCNT/Cu–CuO electrodes in the glucose assay was examined by cyclic voltammetry and chronoamperometric studies. The sensitivity of the sensor varied with the spherulite type; Cu–CuOA, Cu–CuOB, and Cu–CuOC exhibited a sensitivity of 1,229, 3,012, and 3,642 µA mM-1·cm-2, respectively. Moreover, the linear range is dependent on the structure types: 0.023–0.29 mM, 0.07–0.8 mM, and 0.023–0.34 mM for Cu–CuOA, Cu–CuOB, and Cu–CuOC, respectively. An excellent response time of 3 seconds and a low detection limit of 2 µM were observed for Cu–CuOB at an applied potential of +0.34 V. In addition, this electrode was found to be resistant to interference by common interfering agents such as urea, cystamine, l-ascorbic acid, and creatinine. The high performance of the Cu–CuO spherulites with nanowire-to-nanorod outgrowths was primarily due to the high surface area and stability, and good three-dimensional structure. Furthermore, the ITO/MWCNT/Cu–CuOB electrode applied to real urine and serum sample showed satisfactory performance. Keywords: copper oxide, multiwalled carbon nanotubes, glucose sensor, cyclic voltammetry
url http://www.dovepress.com/spherulitic-copperndashcopper-oxide-nanostructure-based-highly-sensiti-peer-reviewed-article-IJN
work_keys_str_mv AT dasg spheruliticcopperndashcopperoxidenanostructurebasedhighlysensitivenonenzymaticglucosesensor
AT trantqn spheruliticcopperndashcopperoxidenanostructurebasedhighlysensitivenonenzymaticglucosesensor
AT yoonhh spheruliticcopperndashcopperoxidenanostructurebasedhighlysensitivenonenzymaticglucosesensor
_version_ 1725817199018377216