Quality assurance of the SCOPE 1 trial in oesophageal radiotherapy

Abstract Background SCOPE 1 was the first UK based multi-centre trial involving radiotherapy of the oesophagus. A comprehensive radiotherapy trials quality assurance programme was launched with two main aims: 1. To assist centres, where needed, to adapt their radiotherapy techniques in order to achi...

Full description

Bibliographic Details
Main Authors: Lucy Wills, Rhydian Maggs, Geraint Lewis, Gareth Jones, Lisette Nixon, John Staffurth, Tom Crosby, on behalf of the SCOPE 1 trial management group and collaborators
Format: Article
Language:English
Published: BMC 2017-11-01
Series:Radiation Oncology
Subjects:
Online Access:http://link.springer.com/article/10.1186/s13014-017-0916-7
id doaj-ae886830ae5441a2906f28395a6d9cab
record_format Article
collection DOAJ
language English
format Article
sources DOAJ
author Lucy Wills
Rhydian Maggs
Geraint Lewis
Gareth Jones
Lisette Nixon
John Staffurth
Tom Crosby
on behalf of the SCOPE 1 trial management group and collaborators
spellingShingle Lucy Wills
Rhydian Maggs
Geraint Lewis
Gareth Jones
Lisette Nixon
John Staffurth
Tom Crosby
on behalf of the SCOPE 1 trial management group and collaborators
Quality assurance of the SCOPE 1 trial in oesophageal radiotherapy
Radiation Oncology
SCOPE 1 clinical trial
Radiotherapy
Quality assurance
Oesophageal cancer
Radiotherapy planning variation
author_facet Lucy Wills
Rhydian Maggs
Geraint Lewis
Gareth Jones
Lisette Nixon
John Staffurth
Tom Crosby
on behalf of the SCOPE 1 trial management group and collaborators
author_sort Lucy Wills
title Quality assurance of the SCOPE 1 trial in oesophageal radiotherapy
title_short Quality assurance of the SCOPE 1 trial in oesophageal radiotherapy
title_full Quality assurance of the SCOPE 1 trial in oesophageal radiotherapy
title_fullStr Quality assurance of the SCOPE 1 trial in oesophageal radiotherapy
title_full_unstemmed Quality assurance of the SCOPE 1 trial in oesophageal radiotherapy
title_sort quality assurance of the scope 1 trial in oesophageal radiotherapy
publisher BMC
series Radiation Oncology
issn 1748-717X
publishDate 2017-11-01
description Abstract Background SCOPE 1 was the first UK based multi-centre trial involving radiotherapy of the oesophagus. A comprehensive radiotherapy trials quality assurance programme was launched with two main aims: 1. To assist centres, where needed, to adapt their radiotherapy techniques in order to achieve protocol compliance and thereby enable their participation in the trial. 2. To support the trial’s clinical outcomes by ensuring the consistent planning and delivery of radiotherapy across all participating centres. Methods A detailed information package was provided and centres were required to complete a benchmark case in which the delineated target volumes and organs at risk, dose distribution and completion of a plan assessment form were assessed prior to recruiting patients into the trial. Upon recruiting, the quality assurance (QA) programme continued to monitor the outlining and planning of radiotherapy treatments. Completion of a questionnaire was requested in order to gather information about each centre’s equipment and techniques relating to their trial participation and to assess the impact of the trial nationally on standard practice for radiotherapy of the oesophagus. During the trial, advice was available for individual planning issues, and was circulated amongst the SCOPE 1 community in response to common areas of concern using bulletins. Results 36 centres were supported through QA processes to enable their participation in SCOPE1. We discuss the issues which have arisen throughout this process and present details of the benchmark case solutions, centre questionnaires and on-trial protocol compliance. The range of submitted benchmark case GTV volumes was 29.8–67.8cm3; and PTV volumes 221.9–513.3 cm3. For the dose distributions associated with these volumes, the percentage volume of the lungs receiving 20Gy (V20Gy) ranged from 20.4 to 33.5%. Similarly, heart V40Gy ranged from 16.1 to 33.0%. Incidence of incorrect outlining of OAR volumes increased from 50% of centres at benchmark case, to 64% on trial. Sixty-five percent of centres, who returned the trial questionnaire, stated that their standard practice had changed as a result of their participation in the SCOPE1 trial. Conclusions The SCOPE 1 QA programme outcomes lend support to the trial’s clinical conclusions. The range of patient planning outcomes for the benchmark case indicated, at the outset of the trial, the significant degree of variation present in UK oesophageal radiotherapy planning outcomes, despite the presence of a protocol. This supports the case for increasingly detailed definition of practice by means of consensus protocols, training and peer review. The incidence of minor inconsistencies of technique highlights the potential for improved QA systems and the need for sufficient resource for this to be addressed within future trials. As indicated in questionnaire responses, the QA exercise as a whole has contributed to greater consistency of oesophageal radiotherapy in the UK via the adoption into standard practice of elements of the protocol. Trial registration The SCOPE1 trial is an International Standard Randomized Controlled Trial, ISRCTN47718479 .
topic SCOPE 1 clinical trial
Radiotherapy
Quality assurance
Oesophageal cancer
Radiotherapy planning variation
url http://link.springer.com/article/10.1186/s13014-017-0916-7
work_keys_str_mv AT lucywills qualityassuranceofthescope1trialinoesophagealradiotherapy
AT rhydianmaggs qualityassuranceofthescope1trialinoesophagealradiotherapy
AT geraintlewis qualityassuranceofthescope1trialinoesophagealradiotherapy
AT garethjones qualityassuranceofthescope1trialinoesophagealradiotherapy
AT lisettenixon qualityassuranceofthescope1trialinoesophagealradiotherapy
AT johnstaffurth qualityassuranceofthescope1trialinoesophagealradiotherapy
AT tomcrosby qualityassuranceofthescope1trialinoesophagealradiotherapy
AT onbehalfofthescope1trialmanagementgroupandcollaborators qualityassuranceofthescope1trialinoesophagealradiotherapy
_version_ 1716797259873517568
spelling doaj-ae886830ae5441a2906f28395a6d9cab2020-11-24T20:53:22ZengBMCRadiation Oncology1748-717X2017-11-0112111010.1186/s13014-017-0916-7Quality assurance of the SCOPE 1 trial in oesophageal radiotherapyLucy Wills0Rhydian Maggs1Geraint Lewis2Gareth Jones3Lisette Nixon4John Staffurth5Tom Crosby6on behalf of the SCOPE 1 trial management group and collaboratorsDepartment of Medical Physics, Velindre Cancer CentreDepartment of Medical Physics, Velindre Cancer CentreDepartment of Medical Physics, Velindre Cancer CentreDepartment of Medical Physics, Velindre Cancer CentreWales Cancer Trials Unit, Centre for Trials Research, Cardiff UniversitySchool of Medicine, Cardiff University, University Hospital WalesDepartment of Clinical Oncology, Velindre Cancer CentreAbstract Background SCOPE 1 was the first UK based multi-centre trial involving radiotherapy of the oesophagus. A comprehensive radiotherapy trials quality assurance programme was launched with two main aims: 1. To assist centres, where needed, to adapt their radiotherapy techniques in order to achieve protocol compliance and thereby enable their participation in the trial. 2. To support the trial’s clinical outcomes by ensuring the consistent planning and delivery of radiotherapy across all participating centres. Methods A detailed information package was provided and centres were required to complete a benchmark case in which the delineated target volumes and organs at risk, dose distribution and completion of a plan assessment form were assessed prior to recruiting patients into the trial. Upon recruiting, the quality assurance (QA) programme continued to monitor the outlining and planning of radiotherapy treatments. Completion of a questionnaire was requested in order to gather information about each centre’s equipment and techniques relating to their trial participation and to assess the impact of the trial nationally on standard practice for radiotherapy of the oesophagus. During the trial, advice was available for individual planning issues, and was circulated amongst the SCOPE 1 community in response to common areas of concern using bulletins. Results 36 centres were supported through QA processes to enable their participation in SCOPE1. We discuss the issues which have arisen throughout this process and present details of the benchmark case solutions, centre questionnaires and on-trial protocol compliance. The range of submitted benchmark case GTV volumes was 29.8–67.8cm3; and PTV volumes 221.9–513.3 cm3. For the dose distributions associated with these volumes, the percentage volume of the lungs receiving 20Gy (V20Gy) ranged from 20.4 to 33.5%. Similarly, heart V40Gy ranged from 16.1 to 33.0%. Incidence of incorrect outlining of OAR volumes increased from 50% of centres at benchmark case, to 64% on trial. Sixty-five percent of centres, who returned the trial questionnaire, stated that their standard practice had changed as a result of their participation in the SCOPE1 trial. Conclusions The SCOPE 1 QA programme outcomes lend support to the trial’s clinical conclusions. The range of patient planning outcomes for the benchmark case indicated, at the outset of the trial, the significant degree of variation present in UK oesophageal radiotherapy planning outcomes, despite the presence of a protocol. This supports the case for increasingly detailed definition of practice by means of consensus protocols, training and peer review. The incidence of minor inconsistencies of technique highlights the potential for improved QA systems and the need for sufficient resource for this to be addressed within future trials. As indicated in questionnaire responses, the QA exercise as a whole has contributed to greater consistency of oesophageal radiotherapy in the UK via the adoption into standard practice of elements of the protocol. Trial registration The SCOPE1 trial is an International Standard Randomized Controlled Trial, ISRCTN47718479 .http://link.springer.com/article/10.1186/s13014-017-0916-7SCOPE 1 clinical trialRadiotherapyQuality assuranceOesophageal cancerRadiotherapy planning variation