Design and construction of a novel measurement device for mechanical characterization of hydrogels: A case study.

Natural biopolymer-based hydrogels especially agarose and collagen gels, considering their biocompatibility with cells and their capacity to mimic biological tissues, have widely been used for in-vitro experiments and tissue engineering applications in recent years; nevertheless their mechanical pro...

Full description

Bibliographic Details
Main Authors: Shayan Shahab, Mehran Kasra, Alireza Dolatshahi-Pirouz
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2021-01-01
Series:PLoS ONE
Online Access:https://doi.org/10.1371/journal.pone.0247727
id doaj-aec2f48e36ce49d58194f69b3ecc4fda
record_format Article
spelling doaj-aec2f48e36ce49d58194f69b3ecc4fda2021-08-23T12:23:38ZengPublic Library of Science (PLoS)PLoS ONE1932-62032021-01-01162e024772710.1371/journal.pone.0247727Design and construction of a novel measurement device for mechanical characterization of hydrogels: A case study.Shayan ShahabMehran KasraAlireza Dolatshahi-PirouzNatural biopolymer-based hydrogels especially agarose and collagen gels, considering their biocompatibility with cells and their capacity to mimic biological tissues, have widely been used for in-vitro experiments and tissue engineering applications in recent years; nevertheless their mechanical properties are not always optimal for these purposes. Regarding the importance of the mechanical properties of hydrogels, many mechanical characterization studies have been carried out for such biopolymers. In this work, we have focused on understanding the mechanical role of agarose and collagen concentration on the hydrogel strength and elastic behavior. In this direction, Amirkabir Magnetic Bead Rheometry (AMBR) characterization device equipped with an optimized electromagnet, was designed and constructed for the measurement of hydrogel mechanical properties. The operation of AMBR set-up is based on applying a magnetic field to actuate magnetic beads in contact with the gel surface in order to actuate the gel itself. In simple terms the magnetic beads leads give rise to mechanical shear stress on the gel surface when under magnetic influence and together with the associated bead-gel displacement it is possible to calculate the hydrogel shear modulus. Agarose and Collagen gels with respectively 0.2-0.6 wt % and 0.2-0.5 wt % percent concentrations were prepared for mechanical characterization in terms of their shear modulus. The shear modulus values for the different percent concentrations of the agarose gel were obtained in the range 250-650 Pa, indicating the shear modulus increases by increasing in the agar gel concentration. In addition to this, the values of shear modulus for the collagen gel increase as function of concentration in the range 240-520 Pa in accordance with an approximately linear relationship between collagen concentration and gel strength.https://doi.org/10.1371/journal.pone.0247727
collection DOAJ
language English
format Article
sources DOAJ
author Shayan Shahab
Mehran Kasra
Alireza Dolatshahi-Pirouz
spellingShingle Shayan Shahab
Mehran Kasra
Alireza Dolatshahi-Pirouz
Design and construction of a novel measurement device for mechanical characterization of hydrogels: A case study.
PLoS ONE
author_facet Shayan Shahab
Mehran Kasra
Alireza Dolatshahi-Pirouz
author_sort Shayan Shahab
title Design and construction of a novel measurement device for mechanical characterization of hydrogels: A case study.
title_short Design and construction of a novel measurement device for mechanical characterization of hydrogels: A case study.
title_full Design and construction of a novel measurement device for mechanical characterization of hydrogels: A case study.
title_fullStr Design and construction of a novel measurement device for mechanical characterization of hydrogels: A case study.
title_full_unstemmed Design and construction of a novel measurement device for mechanical characterization of hydrogels: A case study.
title_sort design and construction of a novel measurement device for mechanical characterization of hydrogels: a case study.
publisher Public Library of Science (PLoS)
series PLoS ONE
issn 1932-6203
publishDate 2021-01-01
description Natural biopolymer-based hydrogels especially agarose and collagen gels, considering their biocompatibility with cells and their capacity to mimic biological tissues, have widely been used for in-vitro experiments and tissue engineering applications in recent years; nevertheless their mechanical properties are not always optimal for these purposes. Regarding the importance of the mechanical properties of hydrogels, many mechanical characterization studies have been carried out for such biopolymers. In this work, we have focused on understanding the mechanical role of agarose and collagen concentration on the hydrogel strength and elastic behavior. In this direction, Amirkabir Magnetic Bead Rheometry (AMBR) characterization device equipped with an optimized electromagnet, was designed and constructed for the measurement of hydrogel mechanical properties. The operation of AMBR set-up is based on applying a magnetic field to actuate magnetic beads in contact with the gel surface in order to actuate the gel itself. In simple terms the magnetic beads leads give rise to mechanical shear stress on the gel surface when under magnetic influence and together with the associated bead-gel displacement it is possible to calculate the hydrogel shear modulus. Agarose and Collagen gels with respectively 0.2-0.6 wt % and 0.2-0.5 wt % percent concentrations were prepared for mechanical characterization in terms of their shear modulus. The shear modulus values for the different percent concentrations of the agarose gel were obtained in the range 250-650 Pa, indicating the shear modulus increases by increasing in the agar gel concentration. In addition to this, the values of shear modulus for the collagen gel increase as function of concentration in the range 240-520 Pa in accordance with an approximately linear relationship between collagen concentration and gel strength.
url https://doi.org/10.1371/journal.pone.0247727
work_keys_str_mv AT shayanshahab designandconstructionofanovelmeasurementdeviceformechanicalcharacterizationofhydrogelsacasestudy
AT mehrankasra designandconstructionofanovelmeasurementdeviceformechanicalcharacterizationofhydrogelsacasestudy
AT alirezadolatshahipirouz designandconstructionofanovelmeasurementdeviceformechanicalcharacterizationofhydrogelsacasestudy
_version_ 1721198434674802688