Theoretical Limit of the Color‐Change Sensitivity of a Composite Resin Dosimeter Film Based on Spiropyran/BaFCl : Eu2+/Polystyrene
Abstract The theoretical limit of the color‐change sensitivity of a composite resin dosimeter film based on 6‐nitro BIPS/BaFCl : Eu2+/polystyrene under X‐ray exposure has been estimated. Each photophysical and photochemical process occurring inside the composite resin dosimeter was quantitatively de...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley-VCH
2020-05-01
|
Series: | ChemistryOpen |
Subjects: | |
Online Access: | https://doi.org/10.1002/open.202000071 |
id |
doaj-aed76b65173845a887a26ee22b5bf80a |
---|---|
record_format |
Article |
spelling |
doaj-aed76b65173845a887a26ee22b5bf80a2021-04-02T10:44:29ZengWiley-VCHChemistryOpen2191-13632020-05-019562362710.1002/open.202000071Theoretical Limit of the Color‐Change Sensitivity of a Composite Resin Dosimeter Film Based on Spiropyran/BaFCl : Eu2+/PolystyreneDr. Kenji Kinashi0Hayato Tsuchida1Dr. Wataru Sakai2Prof. Naoto Tsutsumi3Faculty of Materials Science and Engineering Kyoto Institute of Technology Matsugasaki Sakyo, Kyoto 606-8585 JapanMaster's Program of Innovative Materials Graduate School of Science and Technology Kyoto Institute of Technology Matsugasaki Sakyo, Kyoto 606-8585 JapanFaculty of Materials Science and Engineering Kyoto Institute of Technology Matsugasaki Sakyo, Kyoto 606-8585 JapanFaculty of Materials Science and Engineering Kyoto Institute of Technology Matsugasaki Sakyo, Kyoto 606-8585 JapanAbstract The theoretical limit of the color‐change sensitivity of a composite resin dosimeter film based on 6‐nitro BIPS/BaFCl : Eu2+/polystyrene under X‐ray exposure has been estimated. Each photophysical and photochemical process occurring inside the composite resin dosimeter was quantitatively determined, and the obtained values were used to estimate the theoretical limit of the color‐change sensitivity for the composite resin dosimeter. The values obtained were 70.6 % for the X‐ray absorption efficiency, 13 % for the fluorescence quantum yield, 73.5 % for the UV absorption efficiency and 37.6 % for the photochemical quantum yield. Assuming that the figure‐of‐merit is their product, its value is estimated to be 2.5 %, which contributes to the chromaticity difference and leads to a color‐change sensitivity of 100 mGy. The figure‐of‐merit of a structurally optimized composite dosimeter was estimated to be 1.9 times that of the dosimeter without structural optimization, which showed a sensitivity of 100 mGy. We predicted that the structurally optimized composite resin dosimeter film, which eliminates optical losses due to the structure, will be able to detect X‐ray exposure doses on the order of approximately 28 mGy.https://doi.org/10.1002/open.202000071Composite resin dosimeterColor dosimetersphotochromismspiropyransradioactivity |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Dr. Kenji Kinashi Hayato Tsuchida Dr. Wataru Sakai Prof. Naoto Tsutsumi |
spellingShingle |
Dr. Kenji Kinashi Hayato Tsuchida Dr. Wataru Sakai Prof. Naoto Tsutsumi Theoretical Limit of the Color‐Change Sensitivity of a Composite Resin Dosimeter Film Based on Spiropyran/BaFCl : Eu2+/Polystyrene ChemistryOpen Composite resin dosimeter Color dosimeters photochromism spiropyrans radioactivity |
author_facet |
Dr. Kenji Kinashi Hayato Tsuchida Dr. Wataru Sakai Prof. Naoto Tsutsumi |
author_sort |
Dr. Kenji Kinashi |
title |
Theoretical Limit of the Color‐Change Sensitivity of a Composite Resin Dosimeter Film Based on Spiropyran/BaFCl : Eu2+/Polystyrene |
title_short |
Theoretical Limit of the Color‐Change Sensitivity of a Composite Resin Dosimeter Film Based on Spiropyran/BaFCl : Eu2+/Polystyrene |
title_full |
Theoretical Limit of the Color‐Change Sensitivity of a Composite Resin Dosimeter Film Based on Spiropyran/BaFCl : Eu2+/Polystyrene |
title_fullStr |
Theoretical Limit of the Color‐Change Sensitivity of a Composite Resin Dosimeter Film Based on Spiropyran/BaFCl : Eu2+/Polystyrene |
title_full_unstemmed |
Theoretical Limit of the Color‐Change Sensitivity of a Composite Resin Dosimeter Film Based on Spiropyran/BaFCl : Eu2+/Polystyrene |
title_sort |
theoretical limit of the color‐change sensitivity of a composite resin dosimeter film based on spiropyran/bafcl : eu2+/polystyrene |
publisher |
Wiley-VCH |
series |
ChemistryOpen |
issn |
2191-1363 |
publishDate |
2020-05-01 |
description |
Abstract The theoretical limit of the color‐change sensitivity of a composite resin dosimeter film based on 6‐nitro BIPS/BaFCl : Eu2+/polystyrene under X‐ray exposure has been estimated. Each photophysical and photochemical process occurring inside the composite resin dosimeter was quantitatively determined, and the obtained values were used to estimate the theoretical limit of the color‐change sensitivity for the composite resin dosimeter. The values obtained were 70.6 % for the X‐ray absorption efficiency, 13 % for the fluorescence quantum yield, 73.5 % for the UV absorption efficiency and 37.6 % for the photochemical quantum yield. Assuming that the figure‐of‐merit is their product, its value is estimated to be 2.5 %, which contributes to the chromaticity difference and leads to a color‐change sensitivity of 100 mGy. The figure‐of‐merit of a structurally optimized composite dosimeter was estimated to be 1.9 times that of the dosimeter without structural optimization, which showed a sensitivity of 100 mGy. We predicted that the structurally optimized composite resin dosimeter film, which eliminates optical losses due to the structure, will be able to detect X‐ray exposure doses on the order of approximately 28 mGy. |
topic |
Composite resin dosimeter Color dosimeters photochromism spiropyrans radioactivity |
url |
https://doi.org/10.1002/open.202000071 |
work_keys_str_mv |
AT drkenjikinashi theoreticallimitofthecolorchangesensitivityofacompositeresindosimeterfilmbasedonspiropyranbafcleu2polystyrene AT hayatotsuchida theoreticallimitofthecolorchangesensitivityofacompositeresindosimeterfilmbasedonspiropyranbafcleu2polystyrene AT drwatarusakai theoreticallimitofthecolorchangesensitivityofacompositeresindosimeterfilmbasedonspiropyranbafcleu2polystyrene AT profnaototsutsumi theoreticallimitofthecolorchangesensitivityofacompositeresindosimeterfilmbasedonspiropyranbafcleu2polystyrene |
_version_ |
1724166937973358592 |