Theoretical Limit of the Color‐Change Sensitivity of a Composite Resin Dosimeter Film Based on Spiropyran/BaFCl : Eu2+/Polystyrene

Abstract The theoretical limit of the color‐change sensitivity of a composite resin dosimeter film based on 6‐nitro BIPS/BaFCl : Eu2+/polystyrene under X‐ray exposure has been estimated. Each photophysical and photochemical process occurring inside the composite resin dosimeter was quantitatively de...

Full description

Bibliographic Details
Main Authors: Dr. Kenji Kinashi, Hayato Tsuchida, Dr. Wataru Sakai, Prof. Naoto Tsutsumi
Format: Article
Language:English
Published: Wiley-VCH 2020-05-01
Series:ChemistryOpen
Subjects:
Online Access:https://doi.org/10.1002/open.202000071
id doaj-aed76b65173845a887a26ee22b5bf80a
record_format Article
spelling doaj-aed76b65173845a887a26ee22b5bf80a2021-04-02T10:44:29ZengWiley-VCHChemistryOpen2191-13632020-05-019562362710.1002/open.202000071Theoretical Limit of the Color‐Change Sensitivity of a Composite Resin Dosimeter Film Based on Spiropyran/BaFCl : Eu2+/PolystyreneDr. Kenji Kinashi0Hayato Tsuchida1Dr. Wataru Sakai2Prof. Naoto Tsutsumi3Faculty of Materials Science and Engineering Kyoto Institute of Technology Matsugasaki Sakyo, Kyoto 606-8585 JapanMaster's Program of Innovative Materials Graduate School of Science and Technology Kyoto Institute of Technology Matsugasaki Sakyo, Kyoto 606-8585 JapanFaculty of Materials Science and Engineering Kyoto Institute of Technology Matsugasaki Sakyo, Kyoto 606-8585 JapanFaculty of Materials Science and Engineering Kyoto Institute of Technology Matsugasaki Sakyo, Kyoto 606-8585 JapanAbstract The theoretical limit of the color‐change sensitivity of a composite resin dosimeter film based on 6‐nitro BIPS/BaFCl : Eu2+/polystyrene under X‐ray exposure has been estimated. Each photophysical and photochemical process occurring inside the composite resin dosimeter was quantitatively determined, and the obtained values were used to estimate the theoretical limit of the color‐change sensitivity for the composite resin dosimeter. The values obtained were 70.6 % for the X‐ray absorption efficiency, 13 % for the fluorescence quantum yield, 73.5 % for the UV absorption efficiency and 37.6 % for the photochemical quantum yield. Assuming that the figure‐of‐merit is their product, its value is estimated to be 2.5 %, which contributes to the chromaticity difference and leads to a color‐change sensitivity of 100 mGy. The figure‐of‐merit of a structurally optimized composite dosimeter was estimated to be 1.9 times that of the dosimeter without structural optimization, which showed a sensitivity of 100 mGy. We predicted that the structurally optimized composite resin dosimeter film, which eliminates optical losses due to the structure, will be able to detect X‐ray exposure doses on the order of approximately 28 mGy.https://doi.org/10.1002/open.202000071Composite resin dosimeterColor dosimetersphotochromismspiropyransradioactivity
collection DOAJ
language English
format Article
sources DOAJ
author Dr. Kenji Kinashi
Hayato Tsuchida
Dr. Wataru Sakai
Prof. Naoto Tsutsumi
spellingShingle Dr. Kenji Kinashi
Hayato Tsuchida
Dr. Wataru Sakai
Prof. Naoto Tsutsumi
Theoretical Limit of the Color‐Change Sensitivity of a Composite Resin Dosimeter Film Based on Spiropyran/BaFCl : Eu2+/Polystyrene
ChemistryOpen
Composite resin dosimeter
Color dosimeters
photochromism
spiropyrans
radioactivity
author_facet Dr. Kenji Kinashi
Hayato Tsuchida
Dr. Wataru Sakai
Prof. Naoto Tsutsumi
author_sort Dr. Kenji Kinashi
title Theoretical Limit of the Color‐Change Sensitivity of a Composite Resin Dosimeter Film Based on Spiropyran/BaFCl : Eu2+/Polystyrene
title_short Theoretical Limit of the Color‐Change Sensitivity of a Composite Resin Dosimeter Film Based on Spiropyran/BaFCl : Eu2+/Polystyrene
title_full Theoretical Limit of the Color‐Change Sensitivity of a Composite Resin Dosimeter Film Based on Spiropyran/BaFCl : Eu2+/Polystyrene
title_fullStr Theoretical Limit of the Color‐Change Sensitivity of a Composite Resin Dosimeter Film Based on Spiropyran/BaFCl : Eu2+/Polystyrene
title_full_unstemmed Theoretical Limit of the Color‐Change Sensitivity of a Composite Resin Dosimeter Film Based on Spiropyran/BaFCl : Eu2+/Polystyrene
title_sort theoretical limit of the color‐change sensitivity of a composite resin dosimeter film based on spiropyran/bafcl : eu2+/polystyrene
publisher Wiley-VCH
series ChemistryOpen
issn 2191-1363
publishDate 2020-05-01
description Abstract The theoretical limit of the color‐change sensitivity of a composite resin dosimeter film based on 6‐nitro BIPS/BaFCl : Eu2+/polystyrene under X‐ray exposure has been estimated. Each photophysical and photochemical process occurring inside the composite resin dosimeter was quantitatively determined, and the obtained values were used to estimate the theoretical limit of the color‐change sensitivity for the composite resin dosimeter. The values obtained were 70.6 % for the X‐ray absorption efficiency, 13 % for the fluorescence quantum yield, 73.5 % for the UV absorption efficiency and 37.6 % for the photochemical quantum yield. Assuming that the figure‐of‐merit is their product, its value is estimated to be 2.5 %, which contributes to the chromaticity difference and leads to a color‐change sensitivity of 100 mGy. The figure‐of‐merit of a structurally optimized composite dosimeter was estimated to be 1.9 times that of the dosimeter without structural optimization, which showed a sensitivity of 100 mGy. We predicted that the structurally optimized composite resin dosimeter film, which eliminates optical losses due to the structure, will be able to detect X‐ray exposure doses on the order of approximately 28 mGy.
topic Composite resin dosimeter
Color dosimeters
photochromism
spiropyrans
radioactivity
url https://doi.org/10.1002/open.202000071
work_keys_str_mv AT drkenjikinashi theoreticallimitofthecolorchangesensitivityofacompositeresindosimeterfilmbasedonspiropyranbafcleu2polystyrene
AT hayatotsuchida theoreticallimitofthecolorchangesensitivityofacompositeresindosimeterfilmbasedonspiropyranbafcleu2polystyrene
AT drwatarusakai theoreticallimitofthecolorchangesensitivityofacompositeresindosimeterfilmbasedonspiropyranbafcleu2polystyrene
AT profnaototsutsumi theoreticallimitofthecolorchangesensitivityofacompositeresindosimeterfilmbasedonspiropyranbafcleu2polystyrene
_version_ 1724166937973358592