SYSTEM ANALYSIS OF SCIENTIFIC-AND-TECHNICAL INFORMATION IN AUTOMATIC CONTROL SYSTEM OF POWER UNITS WATTAGE
The production, transformation, transmission, distribution and consumption of electricity is one continuous process. The change of the load, i.e. the level of energy consumption, should cause a corresponding change in the level of generated energy. It means that the power system should be a balance...
Main Authors: | , |
---|---|
Format: | Article |
Language: | Russian |
Published: |
Belarusian National Technical University
2017-09-01
|
Series: | Izvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika |
Subjects: | |
Online Access: | https://energy.bntu.by/jour/article/view/1087 |
id |
doaj-af6dcf43101a4602aef76c3a3e9fdbee |
---|---|
record_format |
Article |
spelling |
doaj-af6dcf43101a4602aef76c3a3e9fdbee2021-07-29T08:45:40ZrusBelarusian National Technical UniversityIzvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika1029-74482414-03412017-09-0160544645810.21122/1029-7448-2017-60-5-446-4581050SYSTEM ANALYSIS OF SCIENTIFIC-AND-TECHNICAL INFORMATION IN AUTOMATIC CONTROL SYSTEM OF POWER UNITS WATTAGEG. T. Kulakov0K. I. Artsiomenka1Belarusian National Technical UniversityBelarusian National Technical UniversityThe production, transformation, transmission, distribution and consumption of electricity is one continuous process. The change of the load, i.e. the level of energy consumption, should cause a corresponding change in the level of generated energy. It means that the power system should be a balance of produced and consumed energy, taking into account technological cost of conversion, transmission and distribution. Otherwise, electric power quality indicators will be violated. For example, at infringement of balance of active power the frequency in the grid will have a value different from 50 Hz. One of the automatic devices on the lowest rung in the hierarchy of automatic dispatcher control system of frequency and power interchange is the system of automatic control of power units (SACPU). It is a comprehensive and complex device, which consists of several connected together simpler systems, governing all thermal power devices of a power unit. SACPU ought to regulate the active power of the unit and participate in primary frequency regulation in the network with a given accuracy and sensitivity; also, it ought to be adequately fast. At the same time, this device should be simple from the point of view of technical implementation, easy to use, allow one to maintain a high level of efficiency, reliability, durability and environmental performance of the units. To satisfy all these requirements (often conflicting) simultaneously, SACPU should have a certain structure, which depends on the composition and characteristics of heat power equipment of the power unit and on operating modes. The analysis of known SACPU have demonstrated that they are unable to fully provide the requirements of the modern standards for quality control of frequency and power, i.e. the SACPU models are still in need of structural and parametric optimization on the basis of the proximate methods developed at the Belarusian National Technical University.https://energy.bntu.by/jour/article/view/1087proximate methods of structure-and-parametric optimizationautomatic control system of power units wattagecontrol of frequency and active-power flows |
collection |
DOAJ |
language |
Russian |
format |
Article |
sources |
DOAJ |
author |
G. T. Kulakov K. I. Artsiomenka |
spellingShingle |
G. T. Kulakov K. I. Artsiomenka SYSTEM ANALYSIS OF SCIENTIFIC-AND-TECHNICAL INFORMATION IN AUTOMATIC CONTROL SYSTEM OF POWER UNITS WATTAGE Izvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika proximate methods of structure-and-parametric optimization automatic control system of power units wattage control of frequency and active-power flows |
author_facet |
G. T. Kulakov K. I. Artsiomenka |
author_sort |
G. T. Kulakov |
title |
SYSTEM ANALYSIS OF SCIENTIFIC-AND-TECHNICAL INFORMATION IN AUTOMATIC CONTROL SYSTEM OF POWER UNITS WATTAGE |
title_short |
SYSTEM ANALYSIS OF SCIENTIFIC-AND-TECHNICAL INFORMATION IN AUTOMATIC CONTROL SYSTEM OF POWER UNITS WATTAGE |
title_full |
SYSTEM ANALYSIS OF SCIENTIFIC-AND-TECHNICAL INFORMATION IN AUTOMATIC CONTROL SYSTEM OF POWER UNITS WATTAGE |
title_fullStr |
SYSTEM ANALYSIS OF SCIENTIFIC-AND-TECHNICAL INFORMATION IN AUTOMATIC CONTROL SYSTEM OF POWER UNITS WATTAGE |
title_full_unstemmed |
SYSTEM ANALYSIS OF SCIENTIFIC-AND-TECHNICAL INFORMATION IN AUTOMATIC CONTROL SYSTEM OF POWER UNITS WATTAGE |
title_sort |
system analysis of scientific-and-technical information in automatic control system of power units wattage |
publisher |
Belarusian National Technical University |
series |
Izvestiâ Vysših Učebnyh Zavedenij i Ènergetičeskih ob Edinennij SNG. Ènergetika |
issn |
1029-7448 2414-0341 |
publishDate |
2017-09-01 |
description |
The production, transformation, transmission, distribution and consumption of electricity is one continuous process. The change of the load, i.e. the level of energy consumption, should cause a corresponding change in the level of generated energy. It means that the power system should be a balance of produced and consumed energy, taking into account technological cost of conversion, transmission and distribution. Otherwise, electric power quality indicators will be violated. For example, at infringement of balance of active power the frequency in the grid will have a value different from 50 Hz. One of the automatic devices on the lowest rung in the hierarchy of automatic dispatcher control system of frequency and power interchange is the system of automatic control of power units (SACPU). It is a comprehensive and complex device, which consists of several connected together simpler systems, governing all thermal power devices of a power unit. SACPU ought to regulate the active power of the unit and participate in primary frequency regulation in the network with a given accuracy and sensitivity; also, it ought to be adequately fast. At the same time, this device should be simple from the point of view of technical implementation, easy to use, allow one to maintain a high level of efficiency, reliability, durability and environmental performance of the units. To satisfy all these requirements (often conflicting) simultaneously, SACPU should have a certain structure, which depends on the composition and characteristics of heat power equipment of the power unit and on operating modes. The analysis of known SACPU have demonstrated that they are unable to fully provide the requirements of the modern standards for quality control of frequency and power, i.e. the SACPU models are still in need of structural and parametric optimization on the basis of the proximate methods developed at the Belarusian National Technical University. |
topic |
proximate methods of structure-and-parametric optimization automatic control system of power units wattage control of frequency and active-power flows |
url |
https://energy.bntu.by/jour/article/view/1087 |
work_keys_str_mv |
AT gtkulakov systemanalysisofscientificandtechnicalinformationinautomaticcontrolsystemofpowerunitswattage AT kiartsiomenka systemanalysisofscientificandtechnicalinformationinautomaticcontrolsystemofpowerunitswattage |
_version_ |
1721251822881996800 |