Effects of Laboratory Disinfecting Agents on Dimensional Stability of Three Commercially Available Heat-Cured Denture Acrylic Resins in India: An In-Vitro Study
Introduction: Dental professionals are exposed to a wide variety of microorganisms which calls for use of effective infection control procedures in the dental office and laboratories that can prevent cross-contamination that could extend to dentists, dental office staff, dental technicians as we...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
JCDR Research and Publications Private Limited
2016-03-01
|
Series: | Journal of Clinical and Diagnostic Research |
Subjects: | |
Online Access: | https://jcdr.net/articles/PDF/7403/17542_CE(EK)_F(AK)_PF1(EKAK)_PFA(AK)_PF2(PAG).pdf |
id |
doaj-b010d3b3bf03413ea3fe77a1ac7ba381 |
---|---|
record_format |
Article |
spelling |
doaj-b010d3b3bf03413ea3fe77a1ac7ba3812020-11-25T02:48:57ZengJCDR Research and Publications Private LimitedJournal of Clinical and Diagnostic Research2249-782X0973-709X2016-03-01103ZC27ZC3110.7860/JCDR/2016/17542.7403 Effects of Laboratory Disinfecting Agents on Dimensional Stability of Three Commercially Available Heat-Cured Denture Acrylic Resins in India: An In-Vitro StudyJayaprakash Mugur Basavanna0Ravikanth Haridas Jujare1Rana Kalappattil Varghese2Vishwa Deepak Singh3Amit Gaurav4Professor, Department of Prosthodontics, Saraswati Dental College, Lucknow, India.Assistant Professor, Department of Prosthodontics, Faculty of Dentistry, Zawia University, Al Zawia, Libya.Dean and Professor and Head, Department of Conservative Dentistry, New Horizon Dental College, Bilaspur, India.Reader, Department of Prosthodontics, Vananchal Dental College Garhwa, Jharkhand, India.Post Graduate Student, Department of Prosthodontics, Saraswati Dental College, Lucknow, India.Introduction: Dental professionals are exposed to a wide variety of microorganisms which calls for use of effective infection control procedures in the dental office and laboratories that can prevent cross-contamination that could extend to dentists, dental office staff, dental technicians as well as patients. This concern has led to a renewed interest in denture sterilization and disinfection. Heat polymerized dentures exhibit dimensional change during disinfection procedure. Aim: The purpose of this study was to determine the influence of different types of widely used laboratory disinfecting agents on the dimensional stability of heat-cured denture acrylic resins and to compare the dimensional stability of three commercially available heat-cured denture acrylic resins in India. Materials and Methods: Twelve specimens of uniform dimension each of three different brands namely Stellon, Trevalon and Acralyn-H were prepared using circular metal disc. Chemical disinfectants namely 2% alkaline glutaraldehyde, 1% povidone-iodine, 0.5% sodium hypochlorite and water as control group were used. Diameter of each specimen was measured before immersion and after immersion with time interval of 1 hour and 12 hours. The data was evaluated statistically using one way analysis of variance. Results: All the specimens in three disinfectants and in water exhibited very small amount of linear expansion. Among three disinfectants, specimens in 2% alkaline glutaraldehyde exhibited least(0.005mm) and water showed highest (0.009mm) amount of dimensional change. Among resins, Trevalon showed least (0.067mm) and Acralyn-H exhibited highest (0.110mm) amount of dimensional change. Conclusion: Although, all the specimens of three different brands of heat-cured denture acrylic resins exhibited increase in linear dimensional change in all the disinfectants and water, they were found to be statistically insignificant.https://jcdr.net/articles/PDF/7403/17542_CE(EK)_F(AK)_PF1(EKAK)_PFA(AK)_PF2(PAG).pdfacrylic resin denturechemical disinfectantscross-contaminationdisinfectionstability |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Jayaprakash Mugur Basavanna Ravikanth Haridas Jujare Rana Kalappattil Varghese Vishwa Deepak Singh Amit Gaurav |
spellingShingle |
Jayaprakash Mugur Basavanna Ravikanth Haridas Jujare Rana Kalappattil Varghese Vishwa Deepak Singh Amit Gaurav Effects of Laboratory Disinfecting Agents on Dimensional Stability of Three Commercially Available Heat-Cured Denture Acrylic Resins in India: An In-Vitro Study Journal of Clinical and Diagnostic Research acrylic resin denture chemical disinfectants cross-contamination disinfection stability |
author_facet |
Jayaprakash Mugur Basavanna Ravikanth Haridas Jujare Rana Kalappattil Varghese Vishwa Deepak Singh Amit Gaurav |
author_sort |
Jayaprakash Mugur Basavanna |
title |
Effects of Laboratory Disinfecting Agents on Dimensional Stability of Three Commercially Available Heat-Cured Denture Acrylic Resins in India: An In-Vitro Study |
title_short |
Effects of Laboratory Disinfecting Agents on Dimensional Stability of Three Commercially Available Heat-Cured Denture Acrylic Resins in India: An In-Vitro Study |
title_full |
Effects of Laboratory Disinfecting Agents on Dimensional Stability of Three Commercially Available Heat-Cured Denture Acrylic Resins in India: An In-Vitro Study |
title_fullStr |
Effects of Laboratory Disinfecting Agents on Dimensional Stability of Three Commercially Available Heat-Cured Denture Acrylic Resins in India: An In-Vitro Study |
title_full_unstemmed |
Effects of Laboratory Disinfecting Agents on Dimensional Stability of Three Commercially Available Heat-Cured Denture Acrylic Resins in India: An In-Vitro Study |
title_sort |
effects of laboratory disinfecting agents on dimensional stability of three commercially available heat-cured denture acrylic resins in india: an in-vitro study |
publisher |
JCDR Research and Publications Private Limited |
series |
Journal of Clinical and Diagnostic Research |
issn |
2249-782X 0973-709X |
publishDate |
2016-03-01 |
description |
Introduction: Dental professionals are exposed to a wide variety
of microorganisms which calls for use of effective infection
control procedures in the dental office and laboratories that
can prevent cross-contamination that could extend to dentists,
dental office staff, dental technicians as well as patients. This
concern has led to a renewed interest in denture sterilization
and disinfection. Heat polymerized dentures exhibit dimensional
change during disinfection procedure.
Aim: The purpose of this study was to determine the influence
of different types of widely used laboratory disinfecting agents
on the dimensional stability of heat-cured denture acrylic resins
and to compare the dimensional stability of three commercially
available heat-cured denture acrylic resins in India.
Materials and Methods: Twelve specimens of uniform
dimension each of three different brands namely Stellon,
Trevalon and Acralyn-H were prepared using circular metal disc.
Chemical disinfectants namely 2% alkaline glutaraldehyde, 1%
povidone-iodine, 0.5% sodium hypochlorite and water as control
group were used. Diameter of each specimen was measured
before immersion and after immersion with time interval of 1
hour and 12 hours. The data was evaluated statistically using
one way analysis of variance.
Results: All the specimens in three disinfectants and in water
exhibited very small amount of linear expansion. Among
three disinfectants, specimens in 2% alkaline glutaraldehyde
exhibited least(0.005mm) and water showed highest (0.009mm)
amount of dimensional change. Among resins, Trevalon showed
least (0.067mm) and Acralyn-H exhibited highest (0.110mm)
amount of dimensional change.
Conclusion: Although, all the specimens of three different
brands of heat-cured denture acrylic resins exhibited increase
in linear dimensional change in all the disinfectants and water,
they were found to be statistically insignificant. |
topic |
acrylic resin denture chemical disinfectants cross-contamination disinfection stability |
url |
https://jcdr.net/articles/PDF/7403/17542_CE(EK)_F(AK)_PF1(EKAK)_PFA(AK)_PF2(PAG).pdf |
work_keys_str_mv |
AT jayaprakashmugurbasavanna effectsoflaboratorydisinfectingagentsondimensionalstabilityofthreecommerciallyavailableheatcureddentureacrylicresinsinindiaaninvitrostudy AT ravikanthharidasjujare effectsoflaboratorydisinfectingagentsondimensionalstabilityofthreecommerciallyavailableheatcureddentureacrylicresinsinindiaaninvitrostudy AT ranakalappattilvarghese effectsoflaboratorydisinfectingagentsondimensionalstabilityofthreecommerciallyavailableheatcureddentureacrylicresinsinindiaaninvitrostudy AT vishwadeepaksingh effectsoflaboratorydisinfectingagentsondimensionalstabilityofthreecommerciallyavailableheatcureddentureacrylicresinsinindiaaninvitrostudy AT amitgaurav effectsoflaboratorydisinfectingagentsondimensionalstabilityofthreecommerciallyavailableheatcureddentureacrylicresinsinindiaaninvitrostudy |
_version_ |
1724745738201595904 |