Long-term comparison of the efficacies of internal and external browpexy combined with blepharoplasty

ABSTRACT Purpose: To perform a long-term comparison of the quantitative efficacy of internal and external browpexy in combination with upper-lid blepharoplasty based on lateral and central eyebrow positions. Methods: This retrospective study evaluated internal and external browpexy with upper-lid...

Full description

Bibliographic Details
Main Authors: Ahmet Kaderli, Yasemin Katircioglu, Evin Singar Ozdemir, Sema Tamer Kaderli
Format: Article
Language:English
Published: Conselho Brasileiro de Oftalmologia
Series:Arquivos Brasileiros de Oftalmologia
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492020000300004&lng=en&tlng=en
id doaj-b0ce2ab37fe9408cb1c374ef1d7abc6d
record_format Article
spelling doaj-b0ce2ab37fe9408cb1c374ef1d7abc6d2020-11-25T03:18:15ZengConselho Brasileiro de OftalmologiaArquivos Brasileiros de Oftalmologia0004-27491678-292583318518910.5935/0004-2749.20200033S0004-27492020000300004Long-term comparison of the efficacies of internal and external browpexy combined with blepharoplastyAhmet KaderliYasemin KatirciogluEvin Singar OzdemirSema Tamer KaderliABSTRACT Purpose: To perform a long-term comparison of the quantitative efficacy of internal and external browpexy in combination with upper-lid blepharoplasty based on lateral and central eyebrow positions. Methods: This retrospective study evaluated internal and external browpexy with upper-lid blepharoplasty surgeries that were performed during the period between January 2012 and December 2017 in the oculoplastic surgery department of our hospital. Patients who had undergone periorbital and forehead surgery, who had ophthalmologic or neurological diseases, and who were Botox users were not included in the study. Preoperative and postoperative measurements were made on photographs taken in the same position. The distances from the pupil center and from the point of intersection between the horizontal line passing through the pupil and the vertical line passing through the lateral canthus to the upper eyebrow borders were measured. Photogrammetric analysis of eyebrow position was analyzed using Corel Draw software. Results: Preoperative and postoperative photographs of 70 eyelids were analyzed. Measurements were taken 24 months after surgery. Mean elevations of 2.10 and 3.19 mm were observed in the central region and lateral regions, respectively, in the internal browpexy group. These elevations were 2.66 and 3.03 mm in the external browpexy group and 0.48 and 0.55 mm in the control group. Eyebrow elevations in the central and lateral regions were not significantly different from baseline in the control group (p=0.126 and p=0.25). Internal and external browpexy showed statistically similar elevation values in the central and lateral regions (p=0.636 and p=0.342). Conclusions: External and internal browpexy surgery afforded adequate and similar elevations of the central and lateral brow, which were significantly different from those in the standard blepharoplasty group during long-term follow-up.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492020000300004&lng=en&tlng=enblefaroplastiasobrancelhasptosis/cirurgiapálpebras/cirurgia
collection DOAJ
language English
format Article
sources DOAJ
author Ahmet Kaderli
Yasemin Katircioglu
Evin Singar Ozdemir
Sema Tamer Kaderli
spellingShingle Ahmet Kaderli
Yasemin Katircioglu
Evin Singar Ozdemir
Sema Tamer Kaderli
Long-term comparison of the efficacies of internal and external browpexy combined with blepharoplasty
Arquivos Brasileiros de Oftalmologia
blefaroplastia
sobrancelhas
ptosis/cirurgia
pálpebras/cirurgia
author_facet Ahmet Kaderli
Yasemin Katircioglu
Evin Singar Ozdemir
Sema Tamer Kaderli
author_sort Ahmet Kaderli
title Long-term comparison of the efficacies of internal and external browpexy combined with blepharoplasty
title_short Long-term comparison of the efficacies of internal and external browpexy combined with blepharoplasty
title_full Long-term comparison of the efficacies of internal and external browpexy combined with blepharoplasty
title_fullStr Long-term comparison of the efficacies of internal and external browpexy combined with blepharoplasty
title_full_unstemmed Long-term comparison of the efficacies of internal and external browpexy combined with blepharoplasty
title_sort long-term comparison of the efficacies of internal and external browpexy combined with blepharoplasty
publisher Conselho Brasileiro de Oftalmologia
series Arquivos Brasileiros de Oftalmologia
issn 0004-2749
1678-2925
description ABSTRACT Purpose: To perform a long-term comparison of the quantitative efficacy of internal and external browpexy in combination with upper-lid blepharoplasty based on lateral and central eyebrow positions. Methods: This retrospective study evaluated internal and external browpexy with upper-lid blepharoplasty surgeries that were performed during the period between January 2012 and December 2017 in the oculoplastic surgery department of our hospital. Patients who had undergone periorbital and forehead surgery, who had ophthalmologic or neurological diseases, and who were Botox users were not included in the study. Preoperative and postoperative measurements were made on photographs taken in the same position. The distances from the pupil center and from the point of intersection between the horizontal line passing through the pupil and the vertical line passing through the lateral canthus to the upper eyebrow borders were measured. Photogrammetric analysis of eyebrow position was analyzed using Corel Draw software. Results: Preoperative and postoperative photographs of 70 eyelids were analyzed. Measurements were taken 24 months after surgery. Mean elevations of 2.10 and 3.19 mm were observed in the central region and lateral regions, respectively, in the internal browpexy group. These elevations were 2.66 and 3.03 mm in the external browpexy group and 0.48 and 0.55 mm in the control group. Eyebrow elevations in the central and lateral regions were not significantly different from baseline in the control group (p=0.126 and p=0.25). Internal and external browpexy showed statistically similar elevation values in the central and lateral regions (p=0.636 and p=0.342). Conclusions: External and internal browpexy surgery afforded adequate and similar elevations of the central and lateral brow, which were significantly different from those in the standard blepharoplasty group during long-term follow-up.
topic blefaroplastia
sobrancelhas
ptosis/cirurgia
pálpebras/cirurgia
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492020000300004&lng=en&tlng=en
work_keys_str_mv AT ahmetkaderli longtermcomparisonoftheefficaciesofinternalandexternalbrowpexycombinedwithblepharoplasty
AT yaseminkatircioglu longtermcomparisonoftheefficaciesofinternalandexternalbrowpexycombinedwithblepharoplasty
AT evinsingarozdemir longtermcomparisonoftheefficaciesofinternalandexternalbrowpexycombinedwithblepharoplasty
AT sematamerkaderli longtermcomparisonoftheefficaciesofinternalandexternalbrowpexycombinedwithblepharoplasty
_version_ 1724627897317064704