Criterion for analyzing experimental data on eddy diffusion coefficients

Problems exist in estimating the eddy heat transport coefficient, <i>K</i><sub>eh</sub>, from experimental data. These problems are due to uncertainty in determining the turbulent energy dissipation rate and to the uncertainty of <i>K</i><sub>eh</sub&g...

Full description

Bibliographic Details
Main Authors: M. N. Vlasov, M. C. Kelley
Format: Article
Language:English
Published: Copernicus Publications 2014-06-01
Series:Annales Geophysicae
Online Access:https://www.ann-geophys.net/32/581/2014/angeo-32-581-2014.pdf
id doaj-b212f99c7a874018a70265c0c7fcedae
record_format Article
spelling doaj-b212f99c7a874018a70265c0c7fcedae2020-11-25T00:04:10ZengCopernicus PublicationsAnnales Geophysicae0992-76891432-05762014-06-013258158810.5194/angeo-32-581-2014Criterion for analyzing experimental data on eddy diffusion coefficientsM. N. Vlasov0M. C. Kelley1School of Electrical and Computer Engineering, Cornell University, Ithaca, NY, USASchool of Electrical and Computer Engineering, Cornell University, Ithaca, NY, USAProblems exist in estimating the eddy heat transport coefficient, <i>K</i><sub>eh</sub>, from experimental data. These problems are due to uncertainty in determining the turbulent energy dissipation rate and to the uncertainty of <i>K</i><sub>eh</sub> dependence on the energy dissipation rate. In this paper, a new criterion for estimating the eddy heat transport coefficient is suggested. This criterion is based on the effect of eddy turbulence on the energy budget of the upper mesosphere and lower thermosphere. The calculations show high cooling around and above the <i>K</i><sub>eh</sub> peak for <i>K</i><sub>eh</sub> values inferred from experimental data. The cooling rates are much higher than cooling rates corresponding to the temperature given by the MSIS-E-90 model or to temperatures measured during the experiments. The main contribution to high cooling rates is due to the term with eddy heat conduction, which strongly depends on the <i>K</i><sub>eh</sub> gradient. According to our results, the heating/cooling values below the <i>K</i><sub>eh</sub> peak altitude correspond to the temperature given by the MSIS-E-90 model, but at the peak and above, the cooling rates are larger by a factor of 2–3 than the rates corresponding to the temperatures. This means that the <i>K</i><sub>eh</sub> values in the peak and above may be overestimated. Application of this criterion to the Turbulent Oxygen Mixing Experiment (TOMEX) data shows that eddy diffusions inferred from observing chemical tracers in TOMEX are strongly overestimated.https://www.ann-geophys.net/32/581/2014/angeo-32-581-2014.pdf
collection DOAJ
language English
format Article
sources DOAJ
author M. N. Vlasov
M. C. Kelley
spellingShingle M. N. Vlasov
M. C. Kelley
Criterion for analyzing experimental data on eddy diffusion coefficients
Annales Geophysicae
author_facet M. N. Vlasov
M. C. Kelley
author_sort M. N. Vlasov
title Criterion for analyzing experimental data on eddy diffusion coefficients
title_short Criterion for analyzing experimental data on eddy diffusion coefficients
title_full Criterion for analyzing experimental data on eddy diffusion coefficients
title_fullStr Criterion for analyzing experimental data on eddy diffusion coefficients
title_full_unstemmed Criterion for analyzing experimental data on eddy diffusion coefficients
title_sort criterion for analyzing experimental data on eddy diffusion coefficients
publisher Copernicus Publications
series Annales Geophysicae
issn 0992-7689
1432-0576
publishDate 2014-06-01
description Problems exist in estimating the eddy heat transport coefficient, <i>K</i><sub>eh</sub>, from experimental data. These problems are due to uncertainty in determining the turbulent energy dissipation rate and to the uncertainty of <i>K</i><sub>eh</sub> dependence on the energy dissipation rate. In this paper, a new criterion for estimating the eddy heat transport coefficient is suggested. This criterion is based on the effect of eddy turbulence on the energy budget of the upper mesosphere and lower thermosphere. The calculations show high cooling around and above the <i>K</i><sub>eh</sub> peak for <i>K</i><sub>eh</sub> values inferred from experimental data. The cooling rates are much higher than cooling rates corresponding to the temperature given by the MSIS-E-90 model or to temperatures measured during the experiments. The main contribution to high cooling rates is due to the term with eddy heat conduction, which strongly depends on the <i>K</i><sub>eh</sub> gradient. According to our results, the heating/cooling values below the <i>K</i><sub>eh</sub> peak altitude correspond to the temperature given by the MSIS-E-90 model, but at the peak and above, the cooling rates are larger by a factor of 2–3 than the rates corresponding to the temperatures. This means that the <i>K</i><sub>eh</sub> values in the peak and above may be overestimated. Application of this criterion to the Turbulent Oxygen Mixing Experiment (TOMEX) data shows that eddy diffusions inferred from observing chemical tracers in TOMEX are strongly overestimated.
url https://www.ann-geophys.net/32/581/2014/angeo-32-581-2014.pdf
work_keys_str_mv AT mnvlasov criterionforanalyzingexperimentaldataoneddydiffusioncoefficients
AT mckelley criterionforanalyzingexperimentaldataoneddydiffusioncoefficients
_version_ 1725430756349575168