Update and, internal and temporal-validation of the FRANCE-2 and ACC-TAVI early-mortality prediction models for Transcatheter aortic Valve Implantation (TAVI) using data from the Netherlands heart registration (NHR)

Background: The predictive performance of the models FRANCE-2 and ACC-TAVI for early-mortality after Transcatheter Aortic Valve Implantation (TAVI) can decline over time and can be enhanced by updating them on new populations. We aim to update and internally and temporally validate these models usin...

Full description

Bibliographic Details
Main Authors: Hatem Al-Farra, Bas A.J.M. de Mol, Anita C.J. Ravelli, W.J.P.P. ter Burg, Saskia Houterman, José P.S. Henriques, Ameen Abu-Hanna
Format: Article
Language:English
Published: Elsevier 2021-02-01
Series:International Journal of Cardiology: Heart & Vasculature
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S235290672100004X
id doaj-b651de7d8a8849fc978edb1f8fc0561e
record_format Article
spelling doaj-b651de7d8a8849fc978edb1f8fc0561e2021-02-27T04:39:18ZengElsevierInternational Journal of Cardiology: Heart & Vasculature2352-90672021-02-0132100716Update and, internal and temporal-validation of the FRANCE-2 and ACC-TAVI early-mortality prediction models for Transcatheter aortic Valve Implantation (TAVI) using data from the Netherlands heart registration (NHR)Hatem Al-Farra0Bas A.J.M. de Mol1Anita C.J. Ravelli2W.J.P.P. ter Burg3Saskia Houterman4José P.S. Henriques5Ameen Abu-Hanna6Department of Medical Informatics, Amsterdam UMC, University of Amsterdam, Amsterdam, the Netherlands; Heart Center, Amsterdam UMC, University of Amsterdam, Amsterdam, the Netherlands; Corresponding author at: Heart center and the department of medical informatics, Amsterdam UMC - Location AMC, University of Amsterdam, P.O. Box 22660, 1105 AZ Amsterdam, the Netherlands.Heart Center, Amsterdam UMC, University of Amsterdam, Amsterdam, the NetherlandsDepartment of Medical Informatics, Amsterdam UMC, University of Amsterdam, Amsterdam, the NetherlandsDepartment of Medical Informatics, Amsterdam UMC, University of Amsterdam, Amsterdam, the NetherlandsNetherlands Heart Registration, Utrecht, the NetherlandsHeart Center, Amsterdam UMC, University of Amsterdam, Amsterdam, the NetherlandsDepartment of Medical Informatics, Amsterdam UMC, University of Amsterdam, Amsterdam, the NetherlandsBackground: The predictive performance of the models FRANCE-2 and ACC-TAVI for early-mortality after Transcatheter Aortic Valve Implantation (TAVI) can decline over time and can be enhanced by updating them on new populations. We aim to update and internally and temporally validate these models using a recent TAVI-cohort from the Netherlands Heart Registration (NHR). Methods: We used data of TAVI-patients treated in 2013–2017. For each original-model, the best update-method (model-intercept, model-recalibration, or model-revision) was selected by a closed-testing procedure. We internally validated both updated models with 1000 bootstrap samples. We also updated the models on the 2013–2016 dataset and temporally validated them on the 2017-dataset. Performance measures were the Area-Under ROC-curve (AU-ROC), Brier-score, and calibration graphs. Results: We included 6177 TAVI-patients, with 4.5% observed early-mortality. The selected update-method for FRANCE-2 was model-intercept-update. Internal validation showed an AU-ROC of 0.63 (95%CI 0.62–0.66) and Brier-score of 0.04 (0.04–0.05). Calibration graphs show that it overestimates early-mortality. In temporal-validation, the AU-ROC was 0.61 (0.53–0.67).The selected update-method for ACC-TAVI was model-revision. In internal-validation, the AU-ROC was 0.63 (0.63–0.66) and Brier-score was 0.04 (0.04–0.05). The updated ACC-TAVI calibrates well up to a probability of 20%, and subsequently underestimates early-mortality. In temporal-validation the AU-ROC was 0.65 (0.58–0.72). Conclusion: Internal-validation of the updated models FRANCE-2 and ACC-TAVI with data from the NHR demonstrated improved performance, which was better than in external-validation studies and comparable to the original studies. In temporal-validation, ACC-TAVI outperformed FRANCE-2 because it suffered less from changes over time.http://www.sciencedirect.com/science/article/pii/S235290672100004XTranscatheter Aortic Valve Implantation (TAVI)Prediction modelModel updatingExternal ValidationModel recalibrationClosed-testing procedure
collection DOAJ
language English
format Article
sources DOAJ
author Hatem Al-Farra
Bas A.J.M. de Mol
Anita C.J. Ravelli
W.J.P.P. ter Burg
Saskia Houterman
José P.S. Henriques
Ameen Abu-Hanna
spellingShingle Hatem Al-Farra
Bas A.J.M. de Mol
Anita C.J. Ravelli
W.J.P.P. ter Burg
Saskia Houterman
José P.S. Henriques
Ameen Abu-Hanna
Update and, internal and temporal-validation of the FRANCE-2 and ACC-TAVI early-mortality prediction models for Transcatheter aortic Valve Implantation (TAVI) using data from the Netherlands heart registration (NHR)
International Journal of Cardiology: Heart & Vasculature
Transcatheter Aortic Valve Implantation (TAVI)
Prediction model
Model updating
External Validation
Model recalibration
Closed-testing procedure
author_facet Hatem Al-Farra
Bas A.J.M. de Mol
Anita C.J. Ravelli
W.J.P.P. ter Burg
Saskia Houterman
José P.S. Henriques
Ameen Abu-Hanna
author_sort Hatem Al-Farra
title Update and, internal and temporal-validation of the FRANCE-2 and ACC-TAVI early-mortality prediction models for Transcatheter aortic Valve Implantation (TAVI) using data from the Netherlands heart registration (NHR)
title_short Update and, internal and temporal-validation of the FRANCE-2 and ACC-TAVI early-mortality prediction models for Transcatheter aortic Valve Implantation (TAVI) using data from the Netherlands heart registration (NHR)
title_full Update and, internal and temporal-validation of the FRANCE-2 and ACC-TAVI early-mortality prediction models for Transcatheter aortic Valve Implantation (TAVI) using data from the Netherlands heart registration (NHR)
title_fullStr Update and, internal and temporal-validation of the FRANCE-2 and ACC-TAVI early-mortality prediction models for Transcatheter aortic Valve Implantation (TAVI) using data from the Netherlands heart registration (NHR)
title_full_unstemmed Update and, internal and temporal-validation of the FRANCE-2 and ACC-TAVI early-mortality prediction models for Transcatheter aortic Valve Implantation (TAVI) using data from the Netherlands heart registration (NHR)
title_sort update and, internal and temporal-validation of the france-2 and acc-tavi early-mortality prediction models for transcatheter aortic valve implantation (tavi) using data from the netherlands heart registration (nhr)
publisher Elsevier
series International Journal of Cardiology: Heart & Vasculature
issn 2352-9067
publishDate 2021-02-01
description Background: The predictive performance of the models FRANCE-2 and ACC-TAVI for early-mortality after Transcatheter Aortic Valve Implantation (TAVI) can decline over time and can be enhanced by updating them on new populations. We aim to update and internally and temporally validate these models using a recent TAVI-cohort from the Netherlands Heart Registration (NHR). Methods: We used data of TAVI-patients treated in 2013–2017. For each original-model, the best update-method (model-intercept, model-recalibration, or model-revision) was selected by a closed-testing procedure. We internally validated both updated models with 1000 bootstrap samples. We also updated the models on the 2013–2016 dataset and temporally validated them on the 2017-dataset. Performance measures were the Area-Under ROC-curve (AU-ROC), Brier-score, and calibration graphs. Results: We included 6177 TAVI-patients, with 4.5% observed early-mortality. The selected update-method for FRANCE-2 was model-intercept-update. Internal validation showed an AU-ROC of 0.63 (95%CI 0.62–0.66) and Brier-score of 0.04 (0.04–0.05). Calibration graphs show that it overestimates early-mortality. In temporal-validation, the AU-ROC was 0.61 (0.53–0.67).The selected update-method for ACC-TAVI was model-revision. In internal-validation, the AU-ROC was 0.63 (0.63–0.66) and Brier-score was 0.04 (0.04–0.05). The updated ACC-TAVI calibrates well up to a probability of 20%, and subsequently underestimates early-mortality. In temporal-validation the AU-ROC was 0.65 (0.58–0.72). Conclusion: Internal-validation of the updated models FRANCE-2 and ACC-TAVI with data from the NHR demonstrated improved performance, which was better than in external-validation studies and comparable to the original studies. In temporal-validation, ACC-TAVI outperformed FRANCE-2 because it suffered less from changes over time.
topic Transcatheter Aortic Valve Implantation (TAVI)
Prediction model
Model updating
External Validation
Model recalibration
Closed-testing procedure
url http://www.sciencedirect.com/science/article/pii/S235290672100004X
work_keys_str_mv AT hatemalfarra updateandinternalandtemporalvalidationofthefrance2andacctaviearlymortalitypredictionmodelsfortranscatheteraorticvalveimplantationtaviusingdatafromthenetherlandsheartregistrationnhr
AT basajmdemol updateandinternalandtemporalvalidationofthefrance2andacctaviearlymortalitypredictionmodelsfortranscatheteraorticvalveimplantationtaviusingdatafromthenetherlandsheartregistrationnhr
AT anitacjravelli updateandinternalandtemporalvalidationofthefrance2andacctaviearlymortalitypredictionmodelsfortranscatheteraorticvalveimplantationtaviusingdatafromthenetherlandsheartregistrationnhr
AT wjppterburg updateandinternalandtemporalvalidationofthefrance2andacctaviearlymortalitypredictionmodelsfortranscatheteraorticvalveimplantationtaviusingdatafromthenetherlandsheartregistrationnhr
AT saskiahouterman updateandinternalandtemporalvalidationofthefrance2andacctaviearlymortalitypredictionmodelsfortranscatheteraorticvalveimplantationtaviusingdatafromthenetherlandsheartregistrationnhr
AT josepshenriques updateandinternalandtemporalvalidationofthefrance2andacctaviearlymortalitypredictionmodelsfortranscatheteraorticvalveimplantationtaviusingdatafromthenetherlandsheartregistrationnhr
AT ameenabuhanna updateandinternalandtemporalvalidationofthefrance2andacctaviearlymortalitypredictionmodelsfortranscatheteraorticvalveimplantationtaviusingdatafromthenetherlandsheartregistrationnhr
_version_ 1724248411472920576