Correlation and Interchangeability of Venous and Capillary Blood Gases in Non-Critically Ill Neonates

BackgroundVenous blood gas (VBG) is frequently used in the neonatal unit as alternative for capillary blood gas (CBG). However, studies reporting correlation are conflicting and data on interchangeability in neonates are lacking.ObjectiveWe investigated the correlation and interchangeability of the...

Full description

Bibliographic Details
Main Authors: Ratna N. G. B. Tan, Steffen C. Pauws, Evelyne van Loon, Vivanne E. H. J. Smits, Enrico Lopriore, Arjan B. te Pas
Format: Article
Language:English
Published: Frontiers Media S.A. 2018-04-01
Series:Frontiers in Pediatrics
Subjects:
Online Access:http://journal.frontiersin.org/article/10.3389/fped.2018.00089/full
id doaj-b70b6154b5c748bcac3fc7442400eced
record_format Article
spelling doaj-b70b6154b5c748bcac3fc7442400eced2020-11-24T23:23:02ZengFrontiers Media S.A.Frontiers in Pediatrics2296-23602018-04-01610.3389/fped.2018.00089333353Correlation and Interchangeability of Venous and Capillary Blood Gases in Non-Critically Ill NeonatesRatna N. G. B. Tan0Steffen C. Pauws1Steffen C. Pauws2Evelyne van Loon3Vivanne E. H. J. Smits4Enrico Lopriore5Arjan B. te Pas6Division of Neonatology, Department of Paediatrics, Leiden University Medical Center, Leiden, NetherlandsDivision of Neonatology, Department of Paediatrics, Leiden University Medical Center, Leiden, NetherlandsTilburg Center for Cognition and Communication, Tilburg University, Tilburg, NetherlandsDivision of Neonatology, Department of Paediatrics, Leiden University Medical Center, Leiden, NetherlandsDivision of Neonatology, Department of Paediatrics, Leiden University Medical Center, Leiden, NetherlandsDivision of Neonatology, Department of Paediatrics, Leiden University Medical Center, Leiden, NetherlandsDivision of Neonatology, Department of Paediatrics, Leiden University Medical Center, Leiden, NetherlandsBackgroundVenous blood gas (VBG) is frequently used in the neonatal unit as alternative for capillary blood gas (CBG). However, studies reporting correlation are conflicting and data on interchangeability in neonates are lacking.ObjectiveWe investigated the correlation and interchangeability of the components between VBG and CBG in infants admitted to the neonatal intensive care unit.MethodsIn a prospective study in the neonatal unit in Leiden University Medical Center (Netherlands), simultaneously VBG and CBG were withdrawn in neonates when both venous puncture and intravenous access as blood gas monitoring was indicated. From each blood gas analysis, a Pearson correlation, intraclass correlation, and Bland–Altman analysis was performed. Clinically acceptable difference for each blood gas value was defined up-front by means of an absolute difference: pH ± 0.05; partial pressure of carbon dioxide (pCO2) (±0.67 kPa = 5 mmHg); partial pressure of oxygen (pO2) (±0.67 kPa = 5 mmHg); base excess ± 3 mmol/l; and bicarbonate (HCO3−) ± 3 mmol/l.ResultsIn 93 patients [median gestational age 31 (IQR 29–34) weeks], 193 paired samples of VBG and CBG were collected. The Pearson correlation between VBG and CBG was very strong for pH (r = 0.79; P < 0.001), BE (r = 0.90; P < 0.001) and bicarbonate (r = 0.87; P < 0.001); strong for pCO2 (r = 0.68; P < 0.001); and moderate for pO2 (r = 0.31; P < 0.001). The percentage of the interchangeability within our acceptable absolute difference for pH was 88%, pCO2 72%, pO2 55%, BE 90%, and bicarbonate 94%.ConclusionVBG and CBG in neonates are well correlated and mostly interchangeable, except for pO2.http://journal.frontiersin.org/article/10.3389/fped.2018.00089/fullblood gasesneonatesvenous blood gascapillary blood gasinterchangeability
collection DOAJ
language English
format Article
sources DOAJ
author Ratna N. G. B. Tan
Steffen C. Pauws
Steffen C. Pauws
Evelyne van Loon
Vivanne E. H. J. Smits
Enrico Lopriore
Arjan B. te Pas
spellingShingle Ratna N. G. B. Tan
Steffen C. Pauws
Steffen C. Pauws
Evelyne van Loon
Vivanne E. H. J. Smits
Enrico Lopriore
Arjan B. te Pas
Correlation and Interchangeability of Venous and Capillary Blood Gases in Non-Critically Ill Neonates
Frontiers in Pediatrics
blood gases
neonates
venous blood gas
capillary blood gas
interchangeability
author_facet Ratna N. G. B. Tan
Steffen C. Pauws
Steffen C. Pauws
Evelyne van Loon
Vivanne E. H. J. Smits
Enrico Lopriore
Arjan B. te Pas
author_sort Ratna N. G. B. Tan
title Correlation and Interchangeability of Venous and Capillary Blood Gases in Non-Critically Ill Neonates
title_short Correlation and Interchangeability of Venous and Capillary Blood Gases in Non-Critically Ill Neonates
title_full Correlation and Interchangeability of Venous and Capillary Blood Gases in Non-Critically Ill Neonates
title_fullStr Correlation and Interchangeability of Venous and Capillary Blood Gases in Non-Critically Ill Neonates
title_full_unstemmed Correlation and Interchangeability of Venous and Capillary Blood Gases in Non-Critically Ill Neonates
title_sort correlation and interchangeability of venous and capillary blood gases in non-critically ill neonates
publisher Frontiers Media S.A.
series Frontiers in Pediatrics
issn 2296-2360
publishDate 2018-04-01
description BackgroundVenous blood gas (VBG) is frequently used in the neonatal unit as alternative for capillary blood gas (CBG). However, studies reporting correlation are conflicting and data on interchangeability in neonates are lacking.ObjectiveWe investigated the correlation and interchangeability of the components between VBG and CBG in infants admitted to the neonatal intensive care unit.MethodsIn a prospective study in the neonatal unit in Leiden University Medical Center (Netherlands), simultaneously VBG and CBG were withdrawn in neonates when both venous puncture and intravenous access as blood gas monitoring was indicated. From each blood gas analysis, a Pearson correlation, intraclass correlation, and Bland–Altman analysis was performed. Clinically acceptable difference for each blood gas value was defined up-front by means of an absolute difference: pH ± 0.05; partial pressure of carbon dioxide (pCO2) (±0.67 kPa = 5 mmHg); partial pressure of oxygen (pO2) (±0.67 kPa = 5 mmHg); base excess ± 3 mmol/l; and bicarbonate (HCO3−) ± 3 mmol/l.ResultsIn 93 patients [median gestational age 31 (IQR 29–34) weeks], 193 paired samples of VBG and CBG were collected. The Pearson correlation between VBG and CBG was very strong for pH (r = 0.79; P < 0.001), BE (r = 0.90; P < 0.001) and bicarbonate (r = 0.87; P < 0.001); strong for pCO2 (r = 0.68; P < 0.001); and moderate for pO2 (r = 0.31; P < 0.001). The percentage of the interchangeability within our acceptable absolute difference for pH was 88%, pCO2 72%, pO2 55%, BE 90%, and bicarbonate 94%.ConclusionVBG and CBG in neonates are well correlated and mostly interchangeable, except for pO2.
topic blood gases
neonates
venous blood gas
capillary blood gas
interchangeability
url http://journal.frontiersin.org/article/10.3389/fped.2018.00089/full
work_keys_str_mv AT ratnangbtan correlationandinterchangeabilityofvenousandcapillarybloodgasesinnoncriticallyillneonates
AT steffencpauws correlationandinterchangeabilityofvenousandcapillarybloodgasesinnoncriticallyillneonates
AT steffencpauws correlationandinterchangeabilityofvenousandcapillarybloodgasesinnoncriticallyillneonates
AT evelynevanloon correlationandinterchangeabilityofvenousandcapillarybloodgasesinnoncriticallyillneonates
AT vivanneehjsmits correlationandinterchangeabilityofvenousandcapillarybloodgasesinnoncriticallyillneonates
AT enricolopriore correlationandinterchangeabilityofvenousandcapillarybloodgasesinnoncriticallyillneonates
AT arjanbtepas correlationandinterchangeabilityofvenousandcapillarybloodgasesinnoncriticallyillneonates
_version_ 1725565797828395008