Intraocular Pressure Calculation in Myopic Patients After Laser-Assisted In Situ Keratomileusis

Hazem Helmy,1 Omar Hashem2 1Glaucoma and Optic Nerve Disease Department, Research Institute of Ophthalmology, Giza, Egypt; 2Cornea and Refractive Surgery Department, Research Institute of Ophthalmology, Giza, EgyptCorrespondence: Hazem Helmy Email hazem.helmy@yahoo.comBackground: Corneal refractive...

Full description

Bibliographic Details
Main Authors: Helmy H, Hashem O
Format: Article
Language:English
Published: Dove Medical Press 2020-02-01
Series:Clinical Ophthalmology
Subjects:
Online Access:https://www.dovepress.com/intraocular-pressure-calculation-in-myopic-patients-after-laser-assist-peer-reviewed-article-OPTH
id doaj-b7a1f41f69674c91948fb8520ceafbfd
record_format Article
spelling doaj-b7a1f41f69674c91948fb8520ceafbfd2020-11-24T21:47:14ZengDove Medical PressClinical Ophthalmology1177-54832020-02-01Volume 1450951651996Intraocular Pressure Calculation in Myopic Patients After Laser-Assisted In Situ KeratomileusisHelmy HHashem OHazem Helmy,1 Omar Hashem2 1Glaucoma and Optic Nerve Disease Department, Research Institute of Ophthalmology, Giza, Egypt; 2Cornea and Refractive Surgery Department, Research Institute of Ophthalmology, Giza, EgyptCorrespondence: Hazem Helmy Email hazem.helmy@yahoo.comBackground: Corneal refractive surgery is widely used worldwide. Myopia is the most common reason for laser-assisted corneal refractive surgery (LASIK) and one of the risk factors for glaucoma. Intraocular pressure (IOP) measurement becomes variable postoperatively as the results are affected by the decrease in corneal thickness and biomechanics. This prospective clinical case study attempted to establish a simple correction formula for the calculation of IOP in post-LASIK myopic patients.Methods: This study included 300 eyes of 150 patients with myopia and myopic astigmatism as a refractive error who underwent LASIK. IOP was measured preoperatively and 6 months postoperatively. Preoperative and postoperative corneal thickness as well as ablation depth were measured. Statistical analysis was performed to detect the relationship between ablation depth and change in IOP. An attempt was made to construct a correction formula for the calculation of post-LASIK IOP.Results: The age of the patients ranged between 18 and 50 (mean ± SD 34.78± 8.8) years. The spherical equivalent of refractive error ranged between − 1.5 and − 10 diopters. The mean IOP decreased significantly from 15.72± 2.37 mmHg preoperatively to 11.71± 2.24 mmHg postoperatively, with a mean difference of  4± 1.75 mmHg (p˂0.001). A positive correlation was detected between corneal thickness and IOP difference among patients both preoperatively and postoperatively (p˂0.001). A positive correlation was identified between ablation depth and IOP change (p˂0.001). The correction formula for IOP was established: Real IOP=4+0.7(preoperative IOP)− 0.3(ablation depth).Conclusion: IOP measurements change after corneal refractive surgery with LASIK. A corrected formula may be a good option for the proper calculation of post-LASIK IOP.Keywords: intraocular pressure calculation, post-LASIK glaucoma, Goldmann applanation tonometry, glaucoma, laser in situ keratomileusishttps://www.dovepress.com/intraocular-pressure-calculation-in-myopic-patients-after-laser-assist-peer-reviewed-article-OPTHintraocular pressure calculationpost lasik glaucomagoldman applanation tonometryglaucomalaser in situ keratomiluesis .
collection DOAJ
language English
format Article
sources DOAJ
author Helmy H
Hashem O
spellingShingle Helmy H
Hashem O
Intraocular Pressure Calculation in Myopic Patients After Laser-Assisted In Situ Keratomileusis
Clinical Ophthalmology
intraocular pressure calculation
post lasik glaucoma
goldman applanation tonometry
glaucoma
laser in situ keratomiluesis .
author_facet Helmy H
Hashem O
author_sort Helmy H
title Intraocular Pressure Calculation in Myopic Patients After Laser-Assisted In Situ Keratomileusis
title_short Intraocular Pressure Calculation in Myopic Patients After Laser-Assisted In Situ Keratomileusis
title_full Intraocular Pressure Calculation in Myopic Patients After Laser-Assisted In Situ Keratomileusis
title_fullStr Intraocular Pressure Calculation in Myopic Patients After Laser-Assisted In Situ Keratomileusis
title_full_unstemmed Intraocular Pressure Calculation in Myopic Patients After Laser-Assisted In Situ Keratomileusis
title_sort intraocular pressure calculation in myopic patients after laser-assisted in situ keratomileusis
publisher Dove Medical Press
series Clinical Ophthalmology
issn 1177-5483
publishDate 2020-02-01
description Hazem Helmy,1 Omar Hashem2 1Glaucoma and Optic Nerve Disease Department, Research Institute of Ophthalmology, Giza, Egypt; 2Cornea and Refractive Surgery Department, Research Institute of Ophthalmology, Giza, EgyptCorrespondence: Hazem Helmy Email hazem.helmy@yahoo.comBackground: Corneal refractive surgery is widely used worldwide. Myopia is the most common reason for laser-assisted corneal refractive surgery (LASIK) and one of the risk factors for glaucoma. Intraocular pressure (IOP) measurement becomes variable postoperatively as the results are affected by the decrease in corneal thickness and biomechanics. This prospective clinical case study attempted to establish a simple correction formula for the calculation of IOP in post-LASIK myopic patients.Methods: This study included 300 eyes of 150 patients with myopia and myopic astigmatism as a refractive error who underwent LASIK. IOP was measured preoperatively and 6 months postoperatively. Preoperative and postoperative corneal thickness as well as ablation depth were measured. Statistical analysis was performed to detect the relationship between ablation depth and change in IOP. An attempt was made to construct a correction formula for the calculation of post-LASIK IOP.Results: The age of the patients ranged between 18 and 50 (mean ± SD 34.78± 8.8) years. The spherical equivalent of refractive error ranged between − 1.5 and − 10 diopters. The mean IOP decreased significantly from 15.72± 2.37 mmHg preoperatively to 11.71± 2.24 mmHg postoperatively, with a mean difference of  4± 1.75 mmHg (p˂0.001). A positive correlation was detected between corneal thickness and IOP difference among patients both preoperatively and postoperatively (p˂0.001). A positive correlation was identified between ablation depth and IOP change (p˂0.001). The correction formula for IOP was established: Real IOP=4+0.7(preoperative IOP)− 0.3(ablation depth).Conclusion: IOP measurements change after corneal refractive surgery with LASIK. A corrected formula may be a good option for the proper calculation of post-LASIK IOP.Keywords: intraocular pressure calculation, post-LASIK glaucoma, Goldmann applanation tonometry, glaucoma, laser in situ keratomileusis
topic intraocular pressure calculation
post lasik glaucoma
goldman applanation tonometry
glaucoma
laser in situ keratomiluesis .
url https://www.dovepress.com/intraocular-pressure-calculation-in-myopic-patients-after-laser-assist-peer-reviewed-article-OPTH
work_keys_str_mv AT helmyh intraocularpressurecalculationinmyopicpatientsafterlaserassistedinsitukeratomileusis
AT hashemo intraocularpressurecalculationinmyopicpatientsafterlaserassistedinsitukeratomileusis
_version_ 1716649905835999232