Research on distributed I/O redundancy method based on domestic PLC
In order to improve the reliability of the acquisition/output link in the PLC control system, the design principle of the redundant system is analyzed, combined with the field application environment and actual needs, a distributed I/O redundancy method based on domestic PLC is developed. The articl...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | zho |
Published: |
National Computer System Engineering Research Institute of China
2021-04-01
|
Series: | Dianzi Jishu Yingyong |
Subjects: | |
Online Access: | http://www.chinaaet.com/article/3000130639 |
id |
doaj-bb38b2e9b456484a83b694157f26b042 |
---|---|
record_format |
Article |
spelling |
doaj-bb38b2e9b456484a83b694157f26b0422021-05-21T06:13:10ZzhoNational Computer System Engineering Research Institute of ChinaDianzi Jishu Yingyong0258-79982021-04-01474828610.16157/j.issn.0258-7998.2005883000130639Research on distributed I/O redundancy method based on domestic PLCLiu Xuefei0Su Shishi1Kuai Liang2Han Qingmin3Wang Shuai4Wu Yunfeng5The 6th Research Institute of China Electronics Corporation,Beijing 102209,ChinaCS&S.Information System Engineering Co.,Ltd.,Beijing 102209,ChinaThe 6th Research Institute of China Electronics Corporation,Beijing 102209,ChinaThe 6th Research Institute of China Electronics Corporation,Beijing 102209,ChinaThe 6th Research Institute of China Electronics Corporation,Beijing 102209,ChinaThe 6th Research Institute of China Electronics Corporation,Beijing 102209,ChinaIn order to improve the reliability of the acquisition/output link in the PLC control system, the design principle of the redundant system is analyzed, combined with the field application environment and actual needs, a distributed I/O redundancy method based on domestic PLC is developed. The article introduces the digital input/output and analog input/output redundancy schemes respectively for the type of data collected. This method takes the self-diagnosis results of the self-diagnosis periodically during operation as the basis for redundant diagnosis, combined with the user-configured redundancy scheme to improve accuracy of collecting/outputting data. It can be known from experiments and on-site base application that this method improves the reliability of the PLC control system and can ensure that the PLC system operates stably, efficiently and safely for a long time.http://www.chinaaet.com/article/3000130639programmable logic controller(plc)reliabilityi/o redundancyfault diagnosis |
collection |
DOAJ |
language |
zho |
format |
Article |
sources |
DOAJ |
author |
Liu Xuefei Su Shishi Kuai Liang Han Qingmin Wang Shuai Wu Yunfeng |
spellingShingle |
Liu Xuefei Su Shishi Kuai Liang Han Qingmin Wang Shuai Wu Yunfeng Research on distributed I/O redundancy method based on domestic PLC Dianzi Jishu Yingyong programmable logic controller(plc) reliability i/o redundancy fault diagnosis |
author_facet |
Liu Xuefei Su Shishi Kuai Liang Han Qingmin Wang Shuai Wu Yunfeng |
author_sort |
Liu Xuefei |
title |
Research on distributed I/O redundancy method based on domestic PLC |
title_short |
Research on distributed I/O redundancy method based on domestic PLC |
title_full |
Research on distributed I/O redundancy method based on domestic PLC |
title_fullStr |
Research on distributed I/O redundancy method based on domestic PLC |
title_full_unstemmed |
Research on distributed I/O redundancy method based on domestic PLC |
title_sort |
research on distributed i/o redundancy method based on domestic plc |
publisher |
National Computer System Engineering Research Institute of China |
series |
Dianzi Jishu Yingyong |
issn |
0258-7998 |
publishDate |
2021-04-01 |
description |
In order to improve the reliability of the acquisition/output link in the PLC control system, the design principle of the redundant system is analyzed, combined with the field application environment and actual needs, a distributed I/O redundancy method based on domestic PLC is developed. The article introduces the digital input/output and analog input/output redundancy schemes respectively for the type of data collected. This method takes the self-diagnosis results of the self-diagnosis periodically during operation as the basis for redundant diagnosis, combined with the user-configured redundancy scheme to improve accuracy of collecting/outputting data. It can be known from experiments and on-site base application that this method improves the reliability of the PLC control system and can ensure that the PLC system operates stably, efficiently and safely for a long time. |
topic |
programmable logic controller(plc) reliability i/o redundancy fault diagnosis |
url |
http://www.chinaaet.com/article/3000130639 |
work_keys_str_mv |
AT liuxuefei researchondistributedioredundancymethodbasedondomesticplc AT sushishi researchondistributedioredundancymethodbasedondomesticplc AT kuailiang researchondistributedioredundancymethodbasedondomesticplc AT hanqingmin researchondistributedioredundancymethodbasedondomesticplc AT wangshuai researchondistributedioredundancymethodbasedondomesticplc AT wuyunfeng researchondistributedioredundancymethodbasedondomesticplc |
_version_ |
1721432459557470208 |