Effects of Thermal Cycles on Interfacial Pressure in MV Cable Joints

The use of medium voltage cable joints is mandatory when dealing with power cable faults and the installation of new lines. However, such an accessory is among the top causes of faults among the grid. To this purpose, one of the quantities monitored to understand the causes of such faults is the int...

Full description

Bibliographic Details
Main Authors: Raffaella Di Sante, Abbas Ghaderi, Alessandro Mingotti, Lorenzo Peretto, Roberto Tinarelli
Format: Article
Language:English
Published: MDPI AG 2019-12-01
Series:Sensors
Subjects:
Online Access:https://www.mdpi.com/1424-8220/20/1/169
id doaj-bb6567479f9d4563a1d81dd3bd30afec
record_format Article
spelling doaj-bb6567479f9d4563a1d81dd3bd30afec2020-11-24T22:07:34ZengMDPI AGSensors1424-82202019-12-0120116910.3390/s20010169s20010169Effects of Thermal Cycles on Interfacial Pressure in MV Cable JointsRaffaella Di Sante0Abbas Ghaderi1Alessandro Mingotti2Lorenzo Peretto3Roberto Tinarelli4Department of Electrical, Electronic and Information Engineering, Guglielmo Marconi Alma Mater Studiorum, University of Bologna, Viale del Risorgimento 2, 40136 Bologna, ItalyDepartment of Electrical, Electronic and Information Engineering, Guglielmo Marconi Alma Mater Studiorum, University of Bologna, Viale del Risorgimento 2, 40136 Bologna, ItalyDepartment of Electrical, Electronic and Information Engineering, Guglielmo Marconi Alma Mater Studiorum, University of Bologna, Viale del Risorgimento 2, 40136 Bologna, ItalyDepartment of Electrical, Electronic and Information Engineering, Guglielmo Marconi Alma Mater Studiorum, University of Bologna, Viale del Risorgimento 2, 40136 Bologna, ItalyDepartment of Electrical, Electronic and Information Engineering, Guglielmo Marconi Alma Mater Studiorum, University of Bologna, Viale del Risorgimento 2, 40136 Bologna, ItalyThe use of medium voltage cable joints is mandatory when dealing with power cable faults and the installation of new lines. However, such an accessory is among the top causes of faults among the grid. To this purpose, one of the quantities monitored to understand the causes of such faults is the interfacial pressure between the insulating layers of the cable joint. In this work, the interfacial pressure between Cross-linked polyethylene (XLPE) and silicon rubber has been evaluated when the cable joint experiences thermal cycles. From the results, the pressure variation caused by the thermal cycles is demonstrated. Such a phenomenon may be connected to the generation of voids and weak spots that accelerate cable joint ageing. Therefore, proper comments and conclusions are drawn.https://www.mdpi.com/1424-8220/20/1/169medium voltagecable jointtemperatureinterfacial pressurexlpesilicon rubberthermal cyclesageing
collection DOAJ
language English
format Article
sources DOAJ
author Raffaella Di Sante
Abbas Ghaderi
Alessandro Mingotti
Lorenzo Peretto
Roberto Tinarelli
spellingShingle Raffaella Di Sante
Abbas Ghaderi
Alessandro Mingotti
Lorenzo Peretto
Roberto Tinarelli
Effects of Thermal Cycles on Interfacial Pressure in MV Cable Joints
Sensors
medium voltage
cable joint
temperature
interfacial pressure
xlpe
silicon rubber
thermal cycles
ageing
author_facet Raffaella Di Sante
Abbas Ghaderi
Alessandro Mingotti
Lorenzo Peretto
Roberto Tinarelli
author_sort Raffaella Di Sante
title Effects of Thermal Cycles on Interfacial Pressure in MV Cable Joints
title_short Effects of Thermal Cycles on Interfacial Pressure in MV Cable Joints
title_full Effects of Thermal Cycles on Interfacial Pressure in MV Cable Joints
title_fullStr Effects of Thermal Cycles on Interfacial Pressure in MV Cable Joints
title_full_unstemmed Effects of Thermal Cycles on Interfacial Pressure in MV Cable Joints
title_sort effects of thermal cycles on interfacial pressure in mv cable joints
publisher MDPI AG
series Sensors
issn 1424-8220
publishDate 2019-12-01
description The use of medium voltage cable joints is mandatory when dealing with power cable faults and the installation of new lines. However, such an accessory is among the top causes of faults among the grid. To this purpose, one of the quantities monitored to understand the causes of such faults is the interfacial pressure between the insulating layers of the cable joint. In this work, the interfacial pressure between Cross-linked polyethylene (XLPE) and silicon rubber has been evaluated when the cable joint experiences thermal cycles. From the results, the pressure variation caused by the thermal cycles is demonstrated. Such a phenomenon may be connected to the generation of voids and weak spots that accelerate cable joint ageing. Therefore, proper comments and conclusions are drawn.
topic medium voltage
cable joint
temperature
interfacial pressure
xlpe
silicon rubber
thermal cycles
ageing
url https://www.mdpi.com/1424-8220/20/1/169
work_keys_str_mv AT raffaelladisante effectsofthermalcyclesoninterfacialpressureinmvcablejoints
AT abbasghaderi effectsofthermalcyclesoninterfacialpressureinmvcablejoints
AT alessandromingotti effectsofthermalcyclesoninterfacialpressureinmvcablejoints
AT lorenzoperetto effectsofthermalcyclesoninterfacialpressureinmvcablejoints
AT robertotinarelli effectsofthermalcyclesoninterfacialpressureinmvcablejoints
_version_ 1725819759728001024