Effects of Thermal Cycles on Interfacial Pressure in MV Cable Joints
The use of medium voltage cable joints is mandatory when dealing with power cable faults and the installation of new lines. However, such an accessory is among the top causes of faults among the grid. To this purpose, one of the quantities monitored to understand the causes of such faults is the int...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2019-12-01
|
Series: | Sensors |
Subjects: | |
Online Access: | https://www.mdpi.com/1424-8220/20/1/169 |
id |
doaj-bb6567479f9d4563a1d81dd3bd30afec |
---|---|
record_format |
Article |
spelling |
doaj-bb6567479f9d4563a1d81dd3bd30afec2020-11-24T22:07:34ZengMDPI AGSensors1424-82202019-12-0120116910.3390/s20010169s20010169Effects of Thermal Cycles on Interfacial Pressure in MV Cable JointsRaffaella Di Sante0Abbas Ghaderi1Alessandro Mingotti2Lorenzo Peretto3Roberto Tinarelli4Department of Electrical, Electronic and Information Engineering, Guglielmo Marconi Alma Mater Studiorum, University of Bologna, Viale del Risorgimento 2, 40136 Bologna, ItalyDepartment of Electrical, Electronic and Information Engineering, Guglielmo Marconi Alma Mater Studiorum, University of Bologna, Viale del Risorgimento 2, 40136 Bologna, ItalyDepartment of Electrical, Electronic and Information Engineering, Guglielmo Marconi Alma Mater Studiorum, University of Bologna, Viale del Risorgimento 2, 40136 Bologna, ItalyDepartment of Electrical, Electronic and Information Engineering, Guglielmo Marconi Alma Mater Studiorum, University of Bologna, Viale del Risorgimento 2, 40136 Bologna, ItalyDepartment of Electrical, Electronic and Information Engineering, Guglielmo Marconi Alma Mater Studiorum, University of Bologna, Viale del Risorgimento 2, 40136 Bologna, ItalyThe use of medium voltage cable joints is mandatory when dealing with power cable faults and the installation of new lines. However, such an accessory is among the top causes of faults among the grid. To this purpose, one of the quantities monitored to understand the causes of such faults is the interfacial pressure between the insulating layers of the cable joint. In this work, the interfacial pressure between Cross-linked polyethylene (XLPE) and silicon rubber has been evaluated when the cable joint experiences thermal cycles. From the results, the pressure variation caused by the thermal cycles is demonstrated. Such a phenomenon may be connected to the generation of voids and weak spots that accelerate cable joint ageing. Therefore, proper comments and conclusions are drawn.https://www.mdpi.com/1424-8220/20/1/169medium voltagecable jointtemperatureinterfacial pressurexlpesilicon rubberthermal cyclesageing |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Raffaella Di Sante Abbas Ghaderi Alessandro Mingotti Lorenzo Peretto Roberto Tinarelli |
spellingShingle |
Raffaella Di Sante Abbas Ghaderi Alessandro Mingotti Lorenzo Peretto Roberto Tinarelli Effects of Thermal Cycles on Interfacial Pressure in MV Cable Joints Sensors medium voltage cable joint temperature interfacial pressure xlpe silicon rubber thermal cycles ageing |
author_facet |
Raffaella Di Sante Abbas Ghaderi Alessandro Mingotti Lorenzo Peretto Roberto Tinarelli |
author_sort |
Raffaella Di Sante |
title |
Effects of Thermal Cycles on Interfacial Pressure in MV Cable Joints |
title_short |
Effects of Thermal Cycles on Interfacial Pressure in MV Cable Joints |
title_full |
Effects of Thermal Cycles on Interfacial Pressure in MV Cable Joints |
title_fullStr |
Effects of Thermal Cycles on Interfacial Pressure in MV Cable Joints |
title_full_unstemmed |
Effects of Thermal Cycles on Interfacial Pressure in MV Cable Joints |
title_sort |
effects of thermal cycles on interfacial pressure in mv cable joints |
publisher |
MDPI AG |
series |
Sensors |
issn |
1424-8220 |
publishDate |
2019-12-01 |
description |
The use of medium voltage cable joints is mandatory when dealing with power cable faults and the installation of new lines. However, such an accessory is among the top causes of faults among the grid. To this purpose, one of the quantities monitored to understand the causes of such faults is the interfacial pressure between the insulating layers of the cable joint. In this work, the interfacial pressure between Cross-linked polyethylene (XLPE) and silicon rubber has been evaluated when the cable joint experiences thermal cycles. From the results, the pressure variation caused by the thermal cycles is demonstrated. Such a phenomenon may be connected to the generation of voids and weak spots that accelerate cable joint ageing. Therefore, proper comments and conclusions are drawn. |
topic |
medium voltage cable joint temperature interfacial pressure xlpe silicon rubber thermal cycles ageing |
url |
https://www.mdpi.com/1424-8220/20/1/169 |
work_keys_str_mv |
AT raffaelladisante effectsofthermalcyclesoninterfacialpressureinmvcablejoints AT abbasghaderi effectsofthermalcyclesoninterfacialpressureinmvcablejoints AT alessandromingotti effectsofthermalcyclesoninterfacialpressureinmvcablejoints AT lorenzoperetto effectsofthermalcyclesoninterfacialpressureinmvcablejoints AT robertotinarelli effectsofthermalcyclesoninterfacialpressureinmvcablejoints |
_version_ |
1725819759728001024 |