Unified ambiguity resolution method based on three PPP Models
The integer characteristics of the ambiguity can be recovered after the correction of fractional cycle biases (FCB), which can significantly shorten the initialization time of precise point positioning (PPP).However, the ambiguity resolution model of the clientend needs to be consistent with servere...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | zho |
Published: |
Surveying and Mapping Press
2020-07-01
|
Series: | Acta Geodaetica et Cartographica Sinica |
Subjects: | |
Online Access: | http://html.rhhz.net/CHXB/html/2020-7-824.htm |
id |
doaj-bb8bb84a6eb24377972e967dd3047f6c |
---|---|
record_format |
Article |
spelling |
doaj-bb8bb84a6eb24377972e967dd3047f6c2020-11-25T03:09:30ZzhoSurveying and Mapping PressActa Geodaetica et Cartographica Sinica1001-15951001-15952020-07-0149782483210.11947/j.AGCS.2020.2019046720200703Unified ambiguity resolution method based on three PPP ModelsDU Zhenqiang0CHAI Hongzhou1XIANG Minzhi2YIN Xiao3LIU Chunhe4Institute of Surveying and Mapping, Information Engineering University, Zhengzhou 450001, ChinatInstitute of Surveying and Mapping, Information Engineering University, Zhengzhou 450001, ChinatInstitute of Surveying and Mapping, Information Engineering University, Zhengzhou 450001, ChinatInstitute of Surveying and Mapping, Information Engineering University, Zhengzhou 450001, ChinatInstitute of Surveying and Mapping, Information Engineering University, Zhengzhou 450001, ChinatThe integer characteristics of the ambiguity can be recovered after the correction of fractional cycle biases (FCB), which can significantly shorten the initialization time of precise point positioning (PPP).However, the ambiguity resolution model of the clientend needs to be consistent with serverend, which may introduce the problem that the client maybe unable to use different FCB products and increases the transmission pressure of the server link. A unified PPP ambiguity resolution method is proposed that based on three PPP models,i.e.,ionosphere-free combination model, uncombined model without prior ionosphere constraint and uncombined model with prior ionosphere constraint.Different clients can use the same FCB product to achieve fast ambiguity resolution.A globally distributed network consisting of 116 MGEX stations is used to generates three kinds of FCB products at the server end, and 50 additional stations are selected at the client end for verification.The experimental results show that the new method solves the problem of ambiguity resolution of PPP at client end when facing different FCB products. Comparable performance with the traditional method can be achieved with regards to in positioning accuracy, convergence time and success rate.http://html.rhhz.net/CHXB/html/2020-7-824.htmprecise point positioningfcbambiguity resolutionunified method |
collection |
DOAJ |
language |
zho |
format |
Article |
sources |
DOAJ |
author |
DU Zhenqiang CHAI Hongzhou XIANG Minzhi YIN Xiao LIU Chunhe |
spellingShingle |
DU Zhenqiang CHAI Hongzhou XIANG Minzhi YIN Xiao LIU Chunhe Unified ambiguity resolution method based on three PPP Models Acta Geodaetica et Cartographica Sinica precise point positioning fcb ambiguity resolution unified method |
author_facet |
DU Zhenqiang CHAI Hongzhou XIANG Minzhi YIN Xiao LIU Chunhe |
author_sort |
DU Zhenqiang |
title |
Unified ambiguity resolution method based on three PPP Models |
title_short |
Unified ambiguity resolution method based on three PPP Models |
title_full |
Unified ambiguity resolution method based on three PPP Models |
title_fullStr |
Unified ambiguity resolution method based on three PPP Models |
title_full_unstemmed |
Unified ambiguity resolution method based on three PPP Models |
title_sort |
unified ambiguity resolution method based on three ppp models |
publisher |
Surveying and Mapping Press |
series |
Acta Geodaetica et Cartographica Sinica |
issn |
1001-1595 1001-1595 |
publishDate |
2020-07-01 |
description |
The integer characteristics of the ambiguity can be recovered after the correction of fractional cycle biases (FCB), which can significantly shorten the initialization time of precise point positioning (PPP).However, the ambiguity resolution model of the clientend needs to be consistent with serverend, which may introduce the problem that the client maybe unable to use different FCB products and increases the transmission pressure of the server link. A unified PPP ambiguity resolution method is proposed that based on three PPP models,i.e.,ionosphere-free combination model, uncombined model without prior ionosphere constraint and uncombined model with prior ionosphere constraint.Different clients can use the same FCB product to achieve fast ambiguity resolution.A globally distributed network consisting of 116 MGEX stations is used to generates three kinds of FCB products at the server end, and 50 additional stations are selected at the client end for verification.The experimental results show that the new method solves the problem of ambiguity resolution of PPP at client end when facing different FCB products. Comparable performance with the traditional method can be achieved with regards to in positioning accuracy, convergence time and success rate. |
topic |
precise point positioning fcb ambiguity resolution unified method |
url |
http://html.rhhz.net/CHXB/html/2020-7-824.htm |
work_keys_str_mv |
AT duzhenqiang unifiedambiguityresolutionmethodbasedonthreepppmodels AT chaihongzhou unifiedambiguityresolutionmethodbasedonthreepppmodels AT xiangminzhi unifiedambiguityresolutionmethodbasedonthreepppmodels AT yinxiao unifiedambiguityresolutionmethodbasedonthreepppmodels AT liuchunhe unifiedambiguityresolutionmethodbasedonthreepppmodels |
_version_ |
1724662254394146816 |