Calibration of digital wide-range neutron power measurement channel for open-pool type research reactor
As the modernization of the nuclear instrumentation system progresses, research reactors have adopted digital wide-range neutron power measurement (DWRNPM) systems. These systems typically monitor the neutron flux across a range of over 10 decades. Because neutron detectors only measure the local ne...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2018-02-01
|
Series: | Nuclear Engineering and Technology |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S173857331730325X |
id |
doaj-be37e7a26f6a462c818069ab18384d04 |
---|---|
record_format |
Article |
spelling |
doaj-be37e7a26f6a462c818069ab18384d042020-11-24T23:21:57ZengElsevierNuclear Engineering and Technology1738-57332018-02-0150120321010.1016/j.net.2017.10.011Calibration of digital wide-range neutron power measurement channel for open-pool type research reactorSungmoon Joo0Jong Bok Lee1Sang Mun Seo2Decommissioning Technology Research Division, Korea Atomic Energy Research Institute, 111 Daedeok-daero 989Beon-gil, Daejeon 34075, Republic of KoreaResearch Reactor System Design Division, Korea Atomic Energy Research Institute, 111 Daedeok-daero 989Beon-gil, Daejeon 34075, Republic of KoreaResearch Reactor System Design Division, Korea Atomic Energy Research Institute, 111 Daedeok-daero 989Beon-gil, Daejeon 34075, Republic of KoreaAs the modernization of the nuclear instrumentation system progresses, research reactors have adopted digital wide-range neutron power measurement (DWRNPM) systems. These systems typically monitor the neutron flux across a range of over 10 decades. Because neutron detectors only measure the local neutron flux at their position, the local neutron flux must be converted to total reactor power through calibration, which involves mapping the local neutron flux level to a reference reactor power. Conventionally, the neutron power range is divided into smaller subranges because the neutron detector signal characteristics and the reference reactor power estimation methods are different for each subrange. Therefore, many factors should be considered when preparing the calibration procedure for DWRNPM channels. The main purpose of this work is to serve as a reference for performing the calibration of DWRNPM systems in research reactors. This work provides a comprehensive overview of the calibration of DWRNPM channels by describing the configuration of the DWRNPM system and by summarizing the theories of operation and the reference power estimation methods with their associated calibration procedure. The calibration procedure was actually performed during the commissioning of an open-pool type research reactor, and the results and experience are documented herein.http://www.sciencedirect.com/science/article/pii/S173857331730325XCommissioningDigital Wide-Range Neutron Power MeasurementFission ChamberNuclear Instrumentation SystemPower CalibrationResearch Reactor |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Sungmoon Joo Jong Bok Lee Sang Mun Seo |
spellingShingle |
Sungmoon Joo Jong Bok Lee Sang Mun Seo Calibration of digital wide-range neutron power measurement channel for open-pool type research reactor Nuclear Engineering and Technology Commissioning Digital Wide-Range Neutron Power Measurement Fission Chamber Nuclear Instrumentation System Power Calibration Research Reactor |
author_facet |
Sungmoon Joo Jong Bok Lee Sang Mun Seo |
author_sort |
Sungmoon Joo |
title |
Calibration of digital wide-range neutron power measurement channel for open-pool type research reactor |
title_short |
Calibration of digital wide-range neutron power measurement channel for open-pool type research reactor |
title_full |
Calibration of digital wide-range neutron power measurement channel for open-pool type research reactor |
title_fullStr |
Calibration of digital wide-range neutron power measurement channel for open-pool type research reactor |
title_full_unstemmed |
Calibration of digital wide-range neutron power measurement channel for open-pool type research reactor |
title_sort |
calibration of digital wide-range neutron power measurement channel for open-pool type research reactor |
publisher |
Elsevier |
series |
Nuclear Engineering and Technology |
issn |
1738-5733 |
publishDate |
2018-02-01 |
description |
As the modernization of the nuclear instrumentation system progresses, research reactors have adopted digital wide-range neutron power measurement (DWRNPM) systems. These systems typically monitor the neutron flux across a range of over 10 decades. Because neutron detectors only measure the local neutron flux at their position, the local neutron flux must be converted to total reactor power through calibration, which involves mapping the local neutron flux level to a reference reactor power.
Conventionally, the neutron power range is divided into smaller subranges because the neutron detector signal characteristics and the reference reactor power estimation methods are different for each subrange. Therefore, many factors should be considered when preparing the calibration procedure for DWRNPM channels. The main purpose of this work is to serve as a reference for performing the calibration of DWRNPM systems in research reactors.
This work provides a comprehensive overview of the calibration of DWRNPM channels by describing the configuration of the DWRNPM system and by summarizing the theories of operation and the reference power estimation methods with their associated calibration procedure. The calibration procedure was actually performed during the commissioning of an open-pool type research reactor, and the results and experience are documented herein. |
topic |
Commissioning Digital Wide-Range Neutron Power Measurement Fission Chamber Nuclear Instrumentation System Power Calibration Research Reactor |
url |
http://www.sciencedirect.com/science/article/pii/S173857331730325X |
work_keys_str_mv |
AT sungmoonjoo calibrationofdigitalwiderangeneutronpowermeasurementchannelforopenpooltyperesearchreactor AT jongboklee calibrationofdigitalwiderangeneutronpowermeasurementchannelforopenpooltyperesearchreactor AT sangmunseo calibrationofdigitalwiderangeneutronpowermeasurementchannelforopenpooltyperesearchreactor |
_version_ |
1725569312983351296 |