Electrolytic corrosion of water pipeline system in the remote distance from stray currents—Case study

Case study of corrosion failure of urban water supply system caused by the harmful effects of stray currents was presented. The failure occurred at a site distant from the sources of these currents namely the tramway and railway traction systems. Diagnosis revealed the stray currents flow to pipelin...

Full description

Bibliographic Details
Main Authors: Krzysztof Zakowski​, Kazimierz Darowicki​, Juliusz Orlikowski​, Agata Jazdzewska​, Stefan Krakowiak​, Maciej Gruszka, Jacek Banas​
Format: Article
Language:English
Published: Elsevier 2016-06-01
Series:Case Studies in Construction Materials
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2214509516300249
id doaj-be8b06e8ef694414a39af24bae306948
record_format Article
spelling doaj-be8b06e8ef694414a39af24bae3069482020-11-24T23:46:03ZengElsevierCase Studies in Construction Materials2214-50952016-06-014C11612410.1016/j.cscm.2016.03.002Electrolytic corrosion of water pipeline system in the remote distance from stray currents—Case studyKrzysztof Zakowski​0Kazimierz Darowicki​1Juliusz Orlikowski​2Agata Jazdzewska​3Stefan Krakowiak​4Maciej Gruszka5Jacek Banas​6Department of Electrochemistry, Corrosion and Materials Engineering, Gdansk University of Technology, Narutowicza 11/12, 80-233 Gdansk, PolandDepartment of Electrochemistry, Corrosion and Materials Engineering, Gdansk University of Technology, Narutowicza 11/12, 80-233 Gdansk, PolandDepartment of Electrochemistry, Corrosion and Materials Engineering, Gdansk University of Technology, Narutowicza 11/12, 80-233 Gdansk, PolandDepartment of Electrochemistry, Corrosion and Materials Engineering, Gdansk University of Technology, Narutowicza 11/12, 80-233 Gdansk, PolandDepartment of Electrochemistry, Corrosion and Materials Engineering, Gdansk University of Technology, Narutowicza 11/12, 80-233 Gdansk, PolandMPWIK S.A.(Municipal Waterworks in Cracow), Senatorska 1, 30-106 Krakow, PolandAGH University of Science and Technology, Reymonta 23, 30-059 Krakow, PolandCase study of corrosion failure of urban water supply system caused by the harmful effects of stray currents was presented. The failure occurred at a site distant from the sources of these currents namely the tramway and railway traction systems. Diagnosis revealed the stray currents flow to pipeline over a remote distance of 800/1000 m from the point of failure. At the point of failure stray currents flowed from the pipeline to the ground through external insulation defects, causing the process of electrolytic corrosion of the metal. Long distance between the affected section of the pipeline and the sources of stray currents excludes the typical protection against stray currents in the form of electrical polarized drainage. Corrosion protection at this point can be achieved by using the earthing electrodes made of magnesium, which will also provide cathodic current protection as galvanic anode.http://www.sciencedirect.com/science/article/pii/S2214509516300249Water pipelineStray currentsStray-current corrosionElectrolytic corrosionCathodic protectionGalvanic anodeCorrosion diagnosis
collection DOAJ
language English
format Article
sources DOAJ
author Krzysztof Zakowski​
Kazimierz Darowicki​
Juliusz Orlikowski​
Agata Jazdzewska​
Stefan Krakowiak​
Maciej Gruszka
Jacek Banas​
spellingShingle Krzysztof Zakowski​
Kazimierz Darowicki​
Juliusz Orlikowski​
Agata Jazdzewska​
Stefan Krakowiak​
Maciej Gruszka
Jacek Banas​
Electrolytic corrosion of water pipeline system in the remote distance from stray currents—Case study
Case Studies in Construction Materials
Water pipeline
Stray currents
Stray-current corrosion
Electrolytic corrosion
Cathodic protection
Galvanic anode
Corrosion diagnosis
author_facet Krzysztof Zakowski​
Kazimierz Darowicki​
Juliusz Orlikowski​
Agata Jazdzewska​
Stefan Krakowiak​
Maciej Gruszka
Jacek Banas​
author_sort Krzysztof Zakowski​
title Electrolytic corrosion of water pipeline system in the remote distance from stray currents—Case study
title_short Electrolytic corrosion of water pipeline system in the remote distance from stray currents—Case study
title_full Electrolytic corrosion of water pipeline system in the remote distance from stray currents—Case study
title_fullStr Electrolytic corrosion of water pipeline system in the remote distance from stray currents—Case study
title_full_unstemmed Electrolytic corrosion of water pipeline system in the remote distance from stray currents—Case study
title_sort electrolytic corrosion of water pipeline system in the remote distance from stray currents—case study
publisher Elsevier
series Case Studies in Construction Materials
issn 2214-5095
publishDate 2016-06-01
description Case study of corrosion failure of urban water supply system caused by the harmful effects of stray currents was presented. The failure occurred at a site distant from the sources of these currents namely the tramway and railway traction systems. Diagnosis revealed the stray currents flow to pipeline over a remote distance of 800/1000 m from the point of failure. At the point of failure stray currents flowed from the pipeline to the ground through external insulation defects, causing the process of electrolytic corrosion of the metal. Long distance between the affected section of the pipeline and the sources of stray currents excludes the typical protection against stray currents in the form of electrical polarized drainage. Corrosion protection at this point can be achieved by using the earthing electrodes made of magnesium, which will also provide cathodic current protection as galvanic anode.
topic Water pipeline
Stray currents
Stray-current corrosion
Electrolytic corrosion
Cathodic protection
Galvanic anode
Corrosion diagnosis
url http://www.sciencedirect.com/science/article/pii/S2214509516300249
work_keys_str_mv AT krzysztofzakowski electrolyticcorrosionofwaterpipelinesystemintheremotedistancefromstraycurrentscasestudy
AT kazimierzdarowicki electrolyticcorrosionofwaterpipelinesystemintheremotedistancefromstraycurrentscasestudy
AT juliuszorlikowski electrolyticcorrosionofwaterpipelinesystemintheremotedistancefromstraycurrentscasestudy
AT agatajazdzewska electrolyticcorrosionofwaterpipelinesystemintheremotedistancefromstraycurrentscasestudy
AT stefankrakowiak electrolyticcorrosionofwaterpipelinesystemintheremotedistancefromstraycurrentscasestudy
AT maciejgruszka electrolyticcorrosionofwaterpipelinesystemintheremotedistancefromstraycurrentscasestudy
AT jacekbanas electrolyticcorrosionofwaterpipelinesystemintheremotedistancefromstraycurrentscasestudy
_version_ 1725494862715813888