Percutaneous repair of iatrogenic subclavian artery injury by suture-mediated closure device
Central venous catheterization through internal jugular vein is done routinely in intensive care units. It is generally safe, more so when the procedure is performed under ultrasound guidance. However, there could be inadvertent puncture of other vessels in the neck when the procedure is not perform...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Thieme Medical and Scientific Publishers Pvt. Ltd.
2016-04-01
|
Series: | Indian Journal of Radiology and Imaging |
Subjects: | |
Online Access: | http://www.thieme-connect.de/DOI/DOI?10.4103/0971-3026.184425 |
Summary: | Central venous catheterization through internal jugular vein is done routinely in intensive care units. It is generally safe, more so when the procedure is performed under ultrasound guidance. However, there could be inadvertent puncture of other vessels in the neck when the procedure is not performed under real-time sonographic guidance. Closure of this vessel opening can pose a challenge if it is an artery, in a location difficult to compress, and is further complicated by deranged coagulation profile. Here, we discuss the removal of an inadvertently placed catheter from subclavian artery with closure of arteriotomy percutaneously using arterial suture-mediated closure device. |
---|---|
ISSN: | 0971-3026 1998-3808 |