A Single-Use, In Vitro Biosensor for the Detection of T-Tau Protein, A Biomarker of Neuro-Degenerative Disorders, in PBS and Human Serum Using Differential Pulse Voltammetry (DPV)

A single-use, in vitro biosensor for the detection of T-Tau protein in phosphate-buffer saline (PBS) and undiluted human serum was designed, manufactured, and tested. Differential pulse voltammetry (DPV) served as the transduction mechanism. This biosensor consisted of three electrodes: working, cou...

Full description

Bibliographic Details
Main Authors: Yifan Dai, Alireza Molazemhosseini, Chung Chiun Liu
Format: Article
Language:English
Published: MDPI AG 2017-02-01
Series:Biosensors
Subjects:
Online Access:http://www.mdpi.com/2079-6374/7/1/10
id doaj-c5c86fbc75c847bd8d5d406efd13bba2
record_format Article
spelling doaj-c5c86fbc75c847bd8d5d406efd13bba22020-11-24T23:35:33ZengMDPI AGBiosensors2079-63742017-02-01711010.3390/bios7010010bios7010010A Single-Use, In Vitro Biosensor for the Detection of T-Tau Protein, A Biomarker of Neuro-Degenerative Disorders, in PBS and Human Serum Using Differential Pulse Voltammetry (DPV)Yifan Dai0Alireza Molazemhosseini1Chung Chiun Liu2Department of Chemical & Biomolecular Engineering and Electronics Design Center, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, OH 44106, USADip. Chimica Materiali e Ing. Chimica “Giulio Natta”, Politecnico di Milano, Via Mancinelli 7, 20131, ItalyDepartment of Chemical & Biomolecular Engineering and Electronics Design Center, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, OH 44106, USAA single-use, in vitro biosensor for the detection of T-Tau protein in phosphate-buffer saline (PBS) and undiluted human serum was designed, manufactured, and tested. Differential pulse voltammetry (DPV) served as the transduction mechanism. This biosensor consisted of three electrodes: working, counter, and reference electrodes fabricated on a PET sheet. Both working and counter electrodes were thin gold film, 10 nm in thickness. Laser ablation technique was used to define the size and structure of the biosensor. The biosensor was produced using cost-effective roll-to-roll process. Self-assembled monolayers (SAM) of 3-mercaptopropionic acid (MPA) were employed to covalently immobilize the anti-T-Tau (T-Tau antibody) on the gold working electrode. A carbodiimide conjugation approach using N-(3-dimethylaminopropyl)-N’-ethylcarbodiimide hydrochloride (EDC) and N–hydroxysuccinimide (NHS) cross-linked anti-T-Tau to the carboxylic groups on one end of the MPA. A T-Tau protein ladder with six isoforms was used in this study. The anti-T-Tau concentration used was 500,000 pg/mL. The T-Tau protein concentration ranged from 1000 pg/mL to 100,000 pg/mL. DPV measurements showed excellent responses, with a good calibration curve. Thus, a practical tool for simple detection of T-Tau protein, a biomarker of neuro-degenerative disorders, has been successfully developed. This tool could also be extended to detect other biomarkers for neuro-degenerative disorders, such as P-Tau protein and β-amyloid 42.http://www.mdpi.com/2079-6374/7/1/10T-Tau protein detectiondifferential pulse voltammetry[Fe(CN)6]3−/4− redox probe3-mercaptopropionic acid (MPA)
collection DOAJ
language English
format Article
sources DOAJ
author Yifan Dai
Alireza Molazemhosseini
Chung Chiun Liu
spellingShingle Yifan Dai
Alireza Molazemhosseini
Chung Chiun Liu
A Single-Use, In Vitro Biosensor for the Detection of T-Tau Protein, A Biomarker of Neuro-Degenerative Disorders, in PBS and Human Serum Using Differential Pulse Voltammetry (DPV)
Biosensors
T-Tau protein detection
differential pulse voltammetry
[Fe(CN)6]3−/4− redox probe
3-mercaptopropionic acid (MPA)
author_facet Yifan Dai
Alireza Molazemhosseini
Chung Chiun Liu
author_sort Yifan Dai
title A Single-Use, In Vitro Biosensor for the Detection of T-Tau Protein, A Biomarker of Neuro-Degenerative Disorders, in PBS and Human Serum Using Differential Pulse Voltammetry (DPV)
title_short A Single-Use, In Vitro Biosensor for the Detection of T-Tau Protein, A Biomarker of Neuro-Degenerative Disorders, in PBS and Human Serum Using Differential Pulse Voltammetry (DPV)
title_full A Single-Use, In Vitro Biosensor for the Detection of T-Tau Protein, A Biomarker of Neuro-Degenerative Disorders, in PBS and Human Serum Using Differential Pulse Voltammetry (DPV)
title_fullStr A Single-Use, In Vitro Biosensor for the Detection of T-Tau Protein, A Biomarker of Neuro-Degenerative Disorders, in PBS and Human Serum Using Differential Pulse Voltammetry (DPV)
title_full_unstemmed A Single-Use, In Vitro Biosensor for the Detection of T-Tau Protein, A Biomarker of Neuro-Degenerative Disorders, in PBS and Human Serum Using Differential Pulse Voltammetry (DPV)
title_sort single-use, in vitro biosensor for the detection of t-tau protein, a biomarker of neuro-degenerative disorders, in pbs and human serum using differential pulse voltammetry (dpv)
publisher MDPI AG
series Biosensors
issn 2079-6374
publishDate 2017-02-01
description A single-use, in vitro biosensor for the detection of T-Tau protein in phosphate-buffer saline (PBS) and undiluted human serum was designed, manufactured, and tested. Differential pulse voltammetry (DPV) served as the transduction mechanism. This biosensor consisted of three electrodes: working, counter, and reference electrodes fabricated on a PET sheet. Both working and counter electrodes were thin gold film, 10 nm in thickness. Laser ablation technique was used to define the size and structure of the biosensor. The biosensor was produced using cost-effective roll-to-roll process. Self-assembled monolayers (SAM) of 3-mercaptopropionic acid (MPA) were employed to covalently immobilize the anti-T-Tau (T-Tau antibody) on the gold working electrode. A carbodiimide conjugation approach using N-(3-dimethylaminopropyl)-N’-ethylcarbodiimide hydrochloride (EDC) and N–hydroxysuccinimide (NHS) cross-linked anti-T-Tau to the carboxylic groups on one end of the MPA. A T-Tau protein ladder with six isoforms was used in this study. The anti-T-Tau concentration used was 500,000 pg/mL. The T-Tau protein concentration ranged from 1000 pg/mL to 100,000 pg/mL. DPV measurements showed excellent responses, with a good calibration curve. Thus, a practical tool for simple detection of T-Tau protein, a biomarker of neuro-degenerative disorders, has been successfully developed. This tool could also be extended to detect other biomarkers for neuro-degenerative disorders, such as P-Tau protein and β-amyloid 42.
topic T-Tau protein detection
differential pulse voltammetry
[Fe(CN)6]3−/4− redox probe
3-mercaptopropionic acid (MPA)
url http://www.mdpi.com/2079-6374/7/1/10
work_keys_str_mv AT yifandai asingleuseinvitrobiosensorforthedetectionofttauproteinabiomarkerofneurodegenerativedisordersinpbsandhumanserumusingdifferentialpulsevoltammetrydpv
AT alirezamolazemhosseini asingleuseinvitrobiosensorforthedetectionofttauproteinabiomarkerofneurodegenerativedisordersinpbsandhumanserumusingdifferentialpulsevoltammetrydpv
AT chungchiunliu asingleuseinvitrobiosensorforthedetectionofttauproteinabiomarkerofneurodegenerativedisordersinpbsandhumanserumusingdifferentialpulsevoltammetrydpv
AT yifandai singleuseinvitrobiosensorforthedetectionofttauproteinabiomarkerofneurodegenerativedisordersinpbsandhumanserumusingdifferentialpulsevoltammetrydpv
AT alirezamolazemhosseini singleuseinvitrobiosensorforthedetectionofttauproteinabiomarkerofneurodegenerativedisordersinpbsandhumanserumusingdifferentialpulsevoltammetrydpv
AT chungchiunliu singleuseinvitrobiosensorforthedetectionofttauproteinabiomarkerofneurodegenerativedisordersinpbsandhumanserumusingdifferentialpulsevoltammetrydpv
_version_ 1725525661159784448