Possible Operation Modes of Moldovan, Ukrainian and Romanian Electrical Power Systems Joint Work

Types of intersystem controlled tie-lines, that may allow the joint work of power systems of Moldova, Ukraine and Romania, are proposed in this paper. The use of intersystem controlled ac transmission lines based on compact one-circuit overhead transmission lines (OHTL) and two-circuit controlled se...

Full description

Bibliographic Details
Main Authors: Postolati V., Bykova E., Berzan V., Boshneaga V., Suslov V., Radilov T.
Format: Article
Language:English
Published: Academy of Sciences of Moldova 2015-08-01
Series:Problems of the Regional Energetics
Subjects:
Online Access:http://journal.ie.asm.md/assets/files/01_02_28_2015.pdf
id doaj-c6c9184934634ea5af45a1ce03dc3821
record_format Article
spelling doaj-c6c9184934634ea5af45a1ce03dc38212020-11-24T23:07:13ZengAcademy of Sciences of MoldovaProblems of the Regional Energetics1857-00702015-08-012015-22(28)16Possible Operation Modes of Moldovan, Ukrainian and Romanian Electrical Power Systems Joint WorkPostolati V.0Bykova E.1Berzan V.2Boshneaga V.3Suslov V.4Radilov T.5Institute of Power Engineering of the Academy of Sciences of Moldova Chisinau, Republi c of MoldovaInstitute of Power Engineering of the Academy of Sciences of Moldova Chisinau, Republi c of MoldovaInstitute of Power Engineering of the Academy of Sciences of Moldova Chisinau, Republi c of MoldovaInstitute of Power Engineering of the Academy of Sciences of Moldova Chisinau, Republi c of MoldovaInstitute of Power Engineering of the Academy of Sciences of Moldova Chisinau, Republi c of MoldovaInstitute of Power Engineering of the Academy of Sciences of Moldova Chisinau, Republi c of MoldovaTypes of intersystem controlled tie-lines, that may allow the joint work of power systems of Moldova, Ukraine and Romania, are proposed in this paper. The use of intersystem controlled ac transmission lines based on compact one-circuit overhead transmission lines (OHTL) and two-circuit controlled self-compensated OHTL (CSCTL) with phase-shifting transformers on the other hand is also stated. Two types of phase-shifting transformers are considered: the first one – with bounded range of phase angle control between the voltage vectors’ system at the output with respect to the other at the input; the second one – with circular rotation of one voltage vectors’ system with respect to the other. The first type of devices is aimed to control the power flows within the system or through the intersystem tie-lines of synchronously operating systems. The second type of phase-shifting transformers is aimed to interconnect power systems that operate non-synchronously and to control the power flows between them through connecting OHTL. The first type of devices was introduced in calculation model in 330 kV Moldavskaya GRES – Chisinau OHTL and the second one – in the OHTL that are connecting the power systems of Moldova and Romania. The dependences of power flows through power system’s and intersystems’ OHTL are established on base of performed calculations, research and analysis.http://journal.ie.asm.md/assets/files/01_02_28_2015.pdfcompact one - circuit and two - circuit controlled self - compensated overhead transmission lines
collection DOAJ
language English
format Article
sources DOAJ
author Postolati V.
Bykova E.
Berzan V.
Boshneaga V.
Suslov V.
Radilov T.
spellingShingle Postolati V.
Bykova E.
Berzan V.
Boshneaga V.
Suslov V.
Radilov T.
Possible Operation Modes of Moldovan, Ukrainian and Romanian Electrical Power Systems Joint Work
Problems of the Regional Energetics
compact one - circuit and two - circuit controlled self - compensated overhead transmission lines
author_facet Postolati V.
Bykova E.
Berzan V.
Boshneaga V.
Suslov V.
Radilov T.
author_sort Postolati V.
title Possible Operation Modes of Moldovan, Ukrainian and Romanian Electrical Power Systems Joint Work
title_short Possible Operation Modes of Moldovan, Ukrainian and Romanian Electrical Power Systems Joint Work
title_full Possible Operation Modes of Moldovan, Ukrainian and Romanian Electrical Power Systems Joint Work
title_fullStr Possible Operation Modes of Moldovan, Ukrainian and Romanian Electrical Power Systems Joint Work
title_full_unstemmed Possible Operation Modes of Moldovan, Ukrainian and Romanian Electrical Power Systems Joint Work
title_sort possible operation modes of moldovan, ukrainian and romanian electrical power systems joint work
publisher Academy of Sciences of Moldova
series Problems of the Regional Energetics
issn 1857-0070
publishDate 2015-08-01
description Types of intersystem controlled tie-lines, that may allow the joint work of power systems of Moldova, Ukraine and Romania, are proposed in this paper. The use of intersystem controlled ac transmission lines based on compact one-circuit overhead transmission lines (OHTL) and two-circuit controlled self-compensated OHTL (CSCTL) with phase-shifting transformers on the other hand is also stated. Two types of phase-shifting transformers are considered: the first one – with bounded range of phase angle control between the voltage vectors’ system at the output with respect to the other at the input; the second one – with circular rotation of one voltage vectors’ system with respect to the other. The first type of devices is aimed to control the power flows within the system or through the intersystem tie-lines of synchronously operating systems. The second type of phase-shifting transformers is aimed to interconnect power systems that operate non-synchronously and to control the power flows between them through connecting OHTL. The first type of devices was introduced in calculation model in 330 kV Moldavskaya GRES – Chisinau OHTL and the second one – in the OHTL that are connecting the power systems of Moldova and Romania. The dependences of power flows through power system’s and intersystems’ OHTL are established on base of performed calculations, research and analysis.
topic compact one - circuit and two - circuit controlled self - compensated overhead transmission lines
url http://journal.ie.asm.md/assets/files/01_02_28_2015.pdf
work_keys_str_mv AT postolativ possibleoperationmodesofmoldovanukrainianandromanianelectricalpowersystemsjointwork
AT bykovae possibleoperationmodesofmoldovanukrainianandromanianelectricalpowersystemsjointwork
AT berzanv possibleoperationmodesofmoldovanukrainianandromanianelectricalpowersystemsjointwork
AT boshneagav possibleoperationmodesofmoldovanukrainianandromanianelectricalpowersystemsjointwork
AT suslovv possibleoperationmodesofmoldovanukrainianandromanianelectricalpowersystemsjointwork
AT radilovt possibleoperationmodesofmoldovanukrainianandromanianelectricalpowersystemsjointwork
_version_ 1725619344345399296