Model of extensive and severe tracheal stenosis in dogs Modelo de estenose traqueal extensa e grave em cães

PURPOSE: To create an animal model of extensive longitudinal tracheal stenosis (TS) that can be useful to test different surgical techniques of tracheal reconstruction. METHODS: Twenty male mongrel dogs were submitted to standard TS and randomly distributed to observation for 3 weeks (n=10) or 6 wee...

Full description

Bibliographic Details
Main Authors: Jairo Vaidergorn, Djalma José Fagundes, Ana Lucia Machado, Rimarcs Gomes Ferreira, Yara Juliano, Neil Ferreira Novo, Paulo de Oliveira Gomes
Format: Article
Language:English
Published: Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia 2008-12-01
Series:Acta Cirurgica Brasileira
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502008000600005
id doaj-c9c52c711c6044cfab490cfbccb2c686
record_format Article
spelling doaj-c9c52c711c6044cfab490cfbccb2c6862020-11-24T23:22:00ZengSociedade Brasileira para o Desenvolvimento da Pesquisa em CirurgiaActa Cirurgica Brasileira0102-86501678-26742008-12-0123649750010.1590/S0102-86502008000600005Model of extensive and severe tracheal stenosis in dogs Modelo de estenose traqueal extensa e grave em cãesJairo VaidergornDjalma José FagundesAna Lucia MachadoRimarcs Gomes FerreiraYara JulianoNeil Ferreira NovoPaulo de Oliveira GomesPURPOSE: To create an animal model of extensive longitudinal tracheal stenosis (TS) that can be useful to test different surgical techniques of tracheal reconstruction. METHODS: Twenty male mongrel dogs were submitted to standard TS and randomly distributed to observation for 3 weeks (n=10) or 6 weeks (n=10). Under general anesthesia, an elliptical area (major axis from 1st to 20th ring and minor axis 40% of tracheal diameter) was resected and the stumps were sutured. The internal and external diameters were measured (before and after the observation time) and the stenosis index was calculated. Blood samples were collected (gasometry, hematocrit and hemoglobin.) before and after the surgical proceedings. RESULTS: The weight was significant lower in the animals of 6 weeks (15,551±3286.2) in comparison with those of 3 weeks observation (17,250±3575.0). No significant differences were noted in the extension of the trachea on the 21st day (21.2± 1.8) or 42nd day (21.1±1.7). The mean (40.1) and the median (40.5) of rings counted on the 21st day were quite similar to mean (38.1) and median (39.0) that were counted on the 42nd day. In the animals of group A (3 weeks) the mean (46.8%) and the median (49.8%) of index stenosis showed no significant difference (Mann Whitney test p<0.001) in comparison with the mean (55.1%) and median (52.4%) of the animals from group B (6 weeks). No mechanical or biochemical distresses were recorded through all period of observation. CONCLUSION: The surgical proceeding was effective to promote a model of longitudinal and extensive tracheal stenosis.<br>OBJETIVO: Criar um modelo de estenose longitudinal extensa que possa ser útil para testar diferentes técnicas operatórias de reconstrução traqueal. MÉTODOS: 20 cães sem raça definida foram submetidos a um procedimento padrão de estenose traqueal extensa e observados por três (n=10) ou seis (n=10) semanas. Sob anestesia geral uma área elíptica (eixo maior do 1º ao 20º anel traqueal e eixo menos com 40% do diâmetro da luz traqueal) foi ressecada e os cotos foram anastomosados de modo término-terminal. O diâmetro interno e externo foi medido (antes e depois do período de observação) e o índice de estenose foi determinado. Amostras de sangue foram coletadas (gasometria, hematócrito e hemoglobina) antes e depois dos procedimentos operatórios. RESULTADOS: O peso foi significantemente menor nos animais de seis semanas (15,551±3286.2) em comparação com os de três semanas (17,250±3575.0). Não houve diferenças significantes entre a extensão da traquéia com três (21.2± 1.8) ou seis (21.1±1.7) semanas. A média (40.1) e a mediana (40.5) dos anéis contados na 3ª semana foi similar à média (38.1) e mediana (39.0 da 6ª semana. A média (46.8%) e mediana (49.8%) do índice de estenose com três semanas não mostrou diferenças significantes (Mann Whitney test p<0.001) com a média 55.1%) e mediana de seis semanas (52.4%). Nenhum sofrimento mecânico ou bioquímico da respiração foi assinalado. CONCLUSÃO: O procedimento foi efetivo para promover um modelo de estenose extensa da traquéia.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502008000600005Estenose TraquealModelos AnimaisCãesTracheal StenosisModels, AnimalDogs
collection DOAJ
language English
format Article
sources DOAJ
author Jairo Vaidergorn
Djalma José Fagundes
Ana Lucia Machado
Rimarcs Gomes Ferreira
Yara Juliano
Neil Ferreira Novo
Paulo de Oliveira Gomes
spellingShingle Jairo Vaidergorn
Djalma José Fagundes
Ana Lucia Machado
Rimarcs Gomes Ferreira
Yara Juliano
Neil Ferreira Novo
Paulo de Oliveira Gomes
Model of extensive and severe tracheal stenosis in dogs Modelo de estenose traqueal extensa e grave em cães
Acta Cirurgica Brasileira
Estenose Traqueal
Modelos Animais
Cães
Tracheal Stenosis
Models, Animal
Dogs
author_facet Jairo Vaidergorn
Djalma José Fagundes
Ana Lucia Machado
Rimarcs Gomes Ferreira
Yara Juliano
Neil Ferreira Novo
Paulo de Oliveira Gomes
author_sort Jairo Vaidergorn
title Model of extensive and severe tracheal stenosis in dogs Modelo de estenose traqueal extensa e grave em cães
title_short Model of extensive and severe tracheal stenosis in dogs Modelo de estenose traqueal extensa e grave em cães
title_full Model of extensive and severe tracheal stenosis in dogs Modelo de estenose traqueal extensa e grave em cães
title_fullStr Model of extensive and severe tracheal stenosis in dogs Modelo de estenose traqueal extensa e grave em cães
title_full_unstemmed Model of extensive and severe tracheal stenosis in dogs Modelo de estenose traqueal extensa e grave em cães
title_sort model of extensive and severe tracheal stenosis in dogs modelo de estenose traqueal extensa e grave em cães
publisher Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia
series Acta Cirurgica Brasileira
issn 0102-8650
1678-2674
publishDate 2008-12-01
description PURPOSE: To create an animal model of extensive longitudinal tracheal stenosis (TS) that can be useful to test different surgical techniques of tracheal reconstruction. METHODS: Twenty male mongrel dogs were submitted to standard TS and randomly distributed to observation for 3 weeks (n=10) or 6 weeks (n=10). Under general anesthesia, an elliptical area (major axis from 1st to 20th ring and minor axis 40% of tracheal diameter) was resected and the stumps were sutured. The internal and external diameters were measured (before and after the observation time) and the stenosis index was calculated. Blood samples were collected (gasometry, hematocrit and hemoglobin.) before and after the surgical proceedings. RESULTS: The weight was significant lower in the animals of 6 weeks (15,551±3286.2) in comparison with those of 3 weeks observation (17,250±3575.0). No significant differences were noted in the extension of the trachea on the 21st day (21.2± 1.8) or 42nd day (21.1±1.7). The mean (40.1) and the median (40.5) of rings counted on the 21st day were quite similar to mean (38.1) and median (39.0) that were counted on the 42nd day. In the animals of group A (3 weeks) the mean (46.8%) and the median (49.8%) of index stenosis showed no significant difference (Mann Whitney test p<0.001) in comparison with the mean (55.1%) and median (52.4%) of the animals from group B (6 weeks). No mechanical or biochemical distresses were recorded through all period of observation. CONCLUSION: The surgical proceeding was effective to promote a model of longitudinal and extensive tracheal stenosis.<br>OBJETIVO: Criar um modelo de estenose longitudinal extensa que possa ser útil para testar diferentes técnicas operatórias de reconstrução traqueal. MÉTODOS: 20 cães sem raça definida foram submetidos a um procedimento padrão de estenose traqueal extensa e observados por três (n=10) ou seis (n=10) semanas. Sob anestesia geral uma área elíptica (eixo maior do 1º ao 20º anel traqueal e eixo menos com 40% do diâmetro da luz traqueal) foi ressecada e os cotos foram anastomosados de modo término-terminal. O diâmetro interno e externo foi medido (antes e depois do período de observação) e o índice de estenose foi determinado. Amostras de sangue foram coletadas (gasometria, hematócrito e hemoglobina) antes e depois dos procedimentos operatórios. RESULTADOS: O peso foi significantemente menor nos animais de seis semanas (15,551±3286.2) em comparação com os de três semanas (17,250±3575.0). Não houve diferenças significantes entre a extensão da traquéia com três (21.2± 1.8) ou seis (21.1±1.7) semanas. A média (40.1) e a mediana (40.5) dos anéis contados na 3ª semana foi similar à média (38.1) e mediana (39.0 da 6ª semana. A média (46.8%) e mediana (49.8%) do índice de estenose com três semanas não mostrou diferenças significantes (Mann Whitney test p<0.001) com a média 55.1%) e mediana de seis semanas (52.4%). Nenhum sofrimento mecânico ou bioquímico da respiração foi assinalado. CONCLUSÃO: O procedimento foi efetivo para promover um modelo de estenose extensa da traquéia.
topic Estenose Traqueal
Modelos Animais
Cães
Tracheal Stenosis
Models, Animal
Dogs
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502008000600005
work_keys_str_mv AT jairovaidergorn modelofextensiveandseveretrachealstenosisindogsmodelodeestenosetraquealextensaegraveemcaes
AT djalmajosefagundes modelofextensiveandseveretrachealstenosisindogsmodelodeestenosetraquealextensaegraveemcaes
AT analuciamachado modelofextensiveandseveretrachealstenosisindogsmodelodeestenosetraquealextensaegraveemcaes
AT rimarcsgomesferreira modelofextensiveandseveretrachealstenosisindogsmodelodeestenosetraquealextensaegraveemcaes
AT yarajuliano modelofextensiveandseveretrachealstenosisindogsmodelodeestenosetraquealextensaegraveemcaes
AT neilferreiranovo modelofextensiveandseveretrachealstenosisindogsmodelodeestenosetraquealextensaegraveemcaes
AT paulodeoliveiragomes modelofextensiveandseveretrachealstenosisindogsmodelodeestenosetraquealextensaegraveemcaes
_version_ 1725568927974555648