Comparison of anterior section parameters using anterior segment optical coherence tomography and ultrasound biomicroscopy in myopic patients after ICL implantation
AIM: To compare the agreement of anterior chamber depth (ACD) and central vault measurements obtained by anterior segment optical coherence tomography (AS-OCT) and ultrasound biomicroscopy (UBM) of post surgical high myopic eyes with posterior chamber phakic intraocular lens (Visian ICL; STAAR Surgi...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Press of International Journal of Ophthalmology (IJO PRESS)
2016-01-01
|
Series: | International Journal of Ophthalmology |
Subjects: | |
Online Access: | http://www.ijo.cn/en_publish/2016/1/20160110.pdf |
id |
doaj-caf7f966ac1a4b1f83773c5dfa04e41a |
---|---|
record_format |
Article |
spelling |
doaj-caf7f966ac1a4b1f83773c5dfa04e41a2020-11-24T22:43:50ZengPress of International Journal of Ophthalmology (IJO PRESS)International Journal of Ophthalmology2222-39592227-48982016-01-0191586210.18240/ijo.2016.01.10Comparison of anterior section parameters using anterior segment optical coherence tomography and ultrasound biomicroscopy in myopic patients after ICL implantationJing Zhang0Hui-Hui Luo1Jing Zhuang2Ke-Ming Yu3State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou 510060, Guangdong Province, ChinaState Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou 510060, Guangdong Province, ChinaState Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou 510060, Guangdong Province, ChinaState Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou 510060, Guangdong Province, ChinaAIM: To compare the agreement of anterior chamber depth (ACD) and central vault measurements obtained by anterior segment optical coherence tomography (AS-OCT) and ultrasound biomicroscopy (UBM) of post surgical high myopic eyes with posterior chamber phakic intraocular lens (Visian ICL; STAAR Surgical) implantation. METHODS: Fifty-two phakic eyes of 28 high myopic patients who underwent implantable Collamer lens (ICL) surgery for the correction of high myopia were studied. The postoperative ACD, the distance between the corneal endothelium and the anterior surface of ICL (cornea-ICL) and the central vault were measured with the AS-OCT system and the UBM system. Intraclass correlation coefficient (ICC) and the Bland-Altman plot were used to evaluate the repeatability and agreement of two devices. RESULTS: The mean ACD, cornea-ICL and central vault in the 52 phakic eyes after ICL surgery was 3.19±0.28 mm, 2.47±0.28 mm, 0.50±0.19 mm by AS-OCT and 3.13±0.25 mm, 2.49±0.25 mm, 0.44±0.19 mm by UBM, respectively. Pairwise comparison of ACD and central vault measurements showed significant differences between AS-OCT and UBM (P<0.05). However, no statistically significant difference was found between these imaging techniques in cornea-ICL (P>0.05). The Pearson correlation coefficient (r) between AS-OCT and UBM measurements for ACD, cornea-ICL and vault was 0.88, 0.80 and 0.89, respectively (P<0.001). The ICC was 0.89-0.94 for the measurements of AS-OCT and UBM. Bland-Altman analysis showed the 95% limits of agreement of ACD, cornea-ICL, central vault measurements between these two devices were -0.20 to 0.32 mm, -0.36 to 0.32 mm and -0.12 to 0.24 mm, respectively. CONCLUSION: Central ACD and vault measurements using AS-OCT demonstrated a slight significantly higher value than using UBM in phakic eyes after ICL surgery. These two devices should not be used interchangeably for measurements of central ACD and vault in patients after phakic intraocular lens implantation.http://www.ijo.cn/en_publish/2016/1/20160110.pdfanterior chamber depthvaultphakic intraocular lensanterior segment imagingoptical coherence tomographyultrasound biomicroscopy |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Jing Zhang Hui-Hui Luo Jing Zhuang Ke-Ming Yu |
spellingShingle |
Jing Zhang Hui-Hui Luo Jing Zhuang Ke-Ming Yu Comparison of anterior section parameters using anterior segment optical coherence tomography and ultrasound biomicroscopy in myopic patients after ICL implantation International Journal of Ophthalmology anterior chamber depth vault phakic intraocular lens anterior segment imaging optical coherence tomography ultrasound biomicroscopy |
author_facet |
Jing Zhang Hui-Hui Luo Jing Zhuang Ke-Ming Yu |
author_sort |
Jing Zhang |
title |
Comparison of anterior section parameters using anterior segment optical coherence tomography and ultrasound biomicroscopy in myopic patients after ICL implantation |
title_short |
Comparison of anterior section parameters using anterior segment optical coherence tomography and ultrasound biomicroscopy in myopic patients after ICL implantation |
title_full |
Comparison of anterior section parameters using anterior segment optical coherence tomography and ultrasound biomicroscopy in myopic patients after ICL implantation |
title_fullStr |
Comparison of anterior section parameters using anterior segment optical coherence tomography and ultrasound biomicroscopy in myopic patients after ICL implantation |
title_full_unstemmed |
Comparison of anterior section parameters using anterior segment optical coherence tomography and ultrasound biomicroscopy in myopic patients after ICL implantation |
title_sort |
comparison of anterior section parameters using anterior segment optical coherence tomography and ultrasound biomicroscopy in myopic patients after icl implantation |
publisher |
Press of International Journal of Ophthalmology (IJO PRESS) |
series |
International Journal of Ophthalmology |
issn |
2222-3959 2227-4898 |
publishDate |
2016-01-01 |
description |
AIM: To compare the agreement of anterior chamber depth (ACD) and central vault measurements obtained by anterior segment optical coherence tomography (AS-OCT) and ultrasound biomicroscopy (UBM) of post surgical high myopic eyes with posterior chamber phakic intraocular lens (Visian ICL; STAAR Surgical) implantation.
METHODS: Fifty-two phakic eyes of 28 high myopic patients who underwent implantable Collamer lens (ICL) surgery for the correction of high myopia were studied. The postoperative ACD, the distance between the corneal endothelium and the anterior surface of ICL (cornea-ICL) and the central vault were measured with the AS-OCT system and the UBM system. Intraclass correlation coefficient (ICC) and the Bland-Altman plot were used to evaluate the repeatability and agreement of two devices.
RESULTS: The mean ACD, cornea-ICL and central vault in the 52 phakic eyes after ICL surgery was 3.19±0.28 mm, 2.47±0.28 mm, 0.50±0.19 mm by AS-OCT and 3.13±0.25 mm, 2.49±0.25 mm, 0.44±0.19 mm by UBM, respectively. Pairwise comparison of ACD and central vault measurements showed significant differences between AS-OCT and UBM (P<0.05). However, no statistically significant difference was found between these imaging techniques in cornea-ICL (P>0.05). The Pearson correlation coefficient (r) between AS-OCT and UBM measurements for ACD, cornea-ICL and vault was 0.88, 0.80 and 0.89, respectively (P<0.001). The ICC was 0.89-0.94 for the measurements of AS-OCT and UBM. Bland-Altman analysis showed the 95% limits of agreement of ACD, cornea-ICL, central vault measurements between these two devices were -0.20 to 0.32 mm, -0.36 to 0.32 mm and -0.12 to 0.24 mm, respectively.
CONCLUSION: Central ACD and vault measurements using AS-OCT demonstrated a slight significantly higher value than using UBM in phakic eyes after ICL surgery. These two devices should not be used interchangeably for measurements of central ACD and vault in patients after phakic intraocular lens implantation. |
topic |
anterior chamber depth vault phakic intraocular lens anterior segment imaging optical coherence tomography ultrasound biomicroscopy |
url |
http://www.ijo.cn/en_publish/2016/1/20160110.pdf |
work_keys_str_mv |
AT jingzhang comparisonofanteriorsectionparametersusinganteriorsegmentopticalcoherencetomographyandultrasoundbiomicroscopyinmyopicpatientsaftericlimplantation AT huihuiluo comparisonofanteriorsectionparametersusinganteriorsegmentopticalcoherencetomographyandultrasoundbiomicroscopyinmyopicpatientsaftericlimplantation AT jingzhuang comparisonofanteriorsectionparametersusinganteriorsegmentopticalcoherencetomographyandultrasoundbiomicroscopyinmyopicpatientsaftericlimplantation AT kemingyu comparisonofanteriorsectionparametersusinganteriorsegmentopticalcoherencetomographyandultrasoundbiomicroscopyinmyopicpatientsaftericlimplantation |
_version_ |
1725694314462314496 |