Study on pH Effect in Process of an Entero-gastric Fiber-optic Sensor Design

The pH effect on design of a fiber optic sensor newly developed for monitoring entero-gastric reflux is investigated. The research has been carried out by utilizing the sensor to measure characteristic absorption of bilirubin standard solution (used as a calibrator) at different pH values from about...

Full description

Bibliographic Details
Main Authors: Shou Wen-de, Gong Jun, Xia Rong-min, Chen Guo-ping
Format: Article
Language:English
Published: MDPI AG 2002-11-01
Series:Sensors
Subjects:
pH
Online Access:http://www.mdpi.com/1424-8220/2/11/447/
id doaj-cbcd14bdff1d41db9021a11ab7cb12a3
record_format Article
spelling doaj-cbcd14bdff1d41db9021a11ab7cb12a32020-11-24T22:57:24ZengMDPI AGSensors1424-82202002-11-0121144745410.3390/s21100447Study on pH Effect in Process of an Entero-gastric Fiber-optic Sensor DesignShou Wen-deGong JunXia Rong-minChen Guo-pingThe pH effect on design of a fiber optic sensor newly developed for monitoring entero-gastric reflux is investigated. The research has been carried out by utilizing the sensor to measure characteristic absorption of bilirubin standard solution (used as a calibrator) at different pH values from about 1 to 8. The results show explicitly that the estimation error according to the calibration curves with pH <7 is significantly lower than that at alkaline pH values. Compared with the in vitro experimental data, the optimum pH range for entero-gastric reflux analysis is proposed to be between 5-6. The possible reasons for estimation error of the fiber optic sensor are given in detail.http://www.mdpi.com/1424-8220/2/11/447/Fiber optic sensorBilirubinpHEntero-gastric reflux
collection DOAJ
language English
format Article
sources DOAJ
author Shou Wen-de
Gong Jun
Xia Rong-min
Chen Guo-ping
spellingShingle Shou Wen-de
Gong Jun
Xia Rong-min
Chen Guo-ping
Study on pH Effect in Process of an Entero-gastric Fiber-optic Sensor Design
Sensors
Fiber optic sensor
Bilirubin
pH
Entero-gastric reflux
author_facet Shou Wen-de
Gong Jun
Xia Rong-min
Chen Guo-ping
author_sort Shou Wen-de
title Study on pH Effect in Process of an Entero-gastric Fiber-optic Sensor Design
title_short Study on pH Effect in Process of an Entero-gastric Fiber-optic Sensor Design
title_full Study on pH Effect in Process of an Entero-gastric Fiber-optic Sensor Design
title_fullStr Study on pH Effect in Process of an Entero-gastric Fiber-optic Sensor Design
title_full_unstemmed Study on pH Effect in Process of an Entero-gastric Fiber-optic Sensor Design
title_sort study on ph effect in process of an entero-gastric fiber-optic sensor design
publisher MDPI AG
series Sensors
issn 1424-8220
publishDate 2002-11-01
description The pH effect on design of a fiber optic sensor newly developed for monitoring entero-gastric reflux is investigated. The research has been carried out by utilizing the sensor to measure characteristic absorption of bilirubin standard solution (used as a calibrator) at different pH values from about 1 to 8. The results show explicitly that the estimation error according to the calibration curves with pH <7 is significantly lower than that at alkaline pH values. Compared with the in vitro experimental data, the optimum pH range for entero-gastric reflux analysis is proposed to be between 5-6. The possible reasons for estimation error of the fiber optic sensor are given in detail.
topic Fiber optic sensor
Bilirubin
pH
Entero-gastric reflux
url http://www.mdpi.com/1424-8220/2/11/447/
work_keys_str_mv AT shouwende studyonpheffectinprocessofanenterogastricfiberopticsensordesign
AT gongjun studyonpheffectinprocessofanenterogastricfiberopticsensordesign
AT xiarongmin studyonpheffectinprocessofanenterogastricfiberopticsensordesign
AT chenguoping studyonpheffectinprocessofanenterogastricfiberopticsensordesign
_version_ 1725650897534451712