Prioritisation of patients on waiting lists for hip and knee arthroplasties and cataract surgery: Instruments validation

<p>Abstract</p> <p>Background</p> <p>Prioritisation instruments were developed for patients on waiting list for hip and knee arthroplasties (AI) and cataract surgery (CI). The aim of the study was to assess their convergent and discriminant validity and inter-observer r...

Full description

Bibliographic Details
Main Authors: Moharra Montse, Espallargues Mireia, Allepuz Alejandro, Comas Mercè, Pons Joan MV
Format: Article
Language:English
Published: BMC 2008-04-01
Series:BMC Health Services Research
Online Access:http://www.biomedcentral.com/1472-6963/8/76
Description
Summary:<p>Abstract</p> <p>Background</p> <p>Prioritisation instruments were developed for patients on waiting list for hip and knee arthroplasties (AI) and cataract surgery (CI). The aim of the study was to assess their convergent and discriminant validity and inter-observer reliability.</p> <p>Methods</p> <p>Multicentre validation study which included orthopaedic surgeons and ophthalmologists from 10 hospitals. Participating doctors were asked to include all eligible patients placed in the waiting list for the procedures under study during the medical visit. Doctors assessed patients' priority through a visual analogue scale (VAS) and administered the prioritisation instrument. Information on socio-demographic data and health-related quality of life (HRQOL) (HUI3, EQ-5D, WOMAC and VF-14) was obtained through a telephone interview with patients. The correlation coefficients between the prioritisation instrument score and VAS and HRQOL were calculated. For the reliability study a self-administered questionnaire, which included hypothetic patients' scenarios, was sent via postal mail to the doctors. The priority of these scenarios was assessed through the prioritisation instrument. The intraclass correlation coefficient (ICC) between doctors was calculated.</p> <p>Results</p> <p>Correlations with VAS were strong for the AI (0.64, CI95%: 0.59–0.68) and for the CI (0.65, CI95%: 0.62–0.69), and moderate between the WOMAC and the AI (0.39, CI95%: 0.33–0.45) and the VF-14 and the CI (0.38, IC95%: 0.33–0.43). The results of the discriminant analysis were in general as expected. Inter-observer reliability was 0.79 (CI95%: 0.64–0.94) for the AI, and 0.79 (CI95%: 0.63–0.95) for the CI.</p> <p>Conclusion</p> <p>The results show acceptable validity and reliability of the prioritisation instruments in establishing priority for surgery.</p>
ISSN:1472-6963