Detection of Erythropoietin in Exhaled Breath Condensate of Nonhypoxic Subjects Using a Multiplex Bead Array

As a noninvasive method, exhaled breath condensate (EBC) has gained importance to improve monitoring of lung diseases and to detect biomarkers. The aim of the study was to investigate, whether erythropoietin (EPO) is detectable in EBC. EBC was collected from 22 consecutive patients as well as from h...

Full description

Bibliographic Details
Main Authors: Christian Schumann, Kathy Triantafilou, Stefan Krueger, Vinzenz Hombach, Martha Triantafilou, Gunther Becher, Philipp M. Lepper
Format: Article
Language:English
Published: Hindawi Limited 2006-01-01
Series:Mediators of Inflammation
Online Access:http://dx.doi.org/10.1155/MI/2006/18061
id doaj-cea7f33cee0d456cb0ea709bf2afe454
record_format Article
spelling doaj-cea7f33cee0d456cb0ea709bf2afe4542020-11-25T01:05:12ZengHindawi LimitedMediators of Inflammation0962-93511466-18612006-01-01200610.1155/MI/2006/1806118061Detection of Erythropoietin in Exhaled Breath Condensate of Nonhypoxic Subjects Using a Multiplex Bead ArrayChristian Schumann0Kathy Triantafilou1Stefan Krueger2Vinzenz Hombach3Martha Triantafilou4Gunther Becher5Philipp M. Lepper6Department of Internal Medicine II, Section of Pulmonary Medicine, University of Ulm, Robert-Koch-Straβe 8 89081, Ulm, GermanyInfection and Immunity Group, School of Life Sciences, University of Sussex, Brighton BN1 9QG, UKDepartment of Internal Medicine II, Section of Pulmonary Medicine, University of Ulm, Robert-Koch-Straβe 8 89081, Ulm, GermanyDepartment of Internal Medicine II, Section of Pulmonary Medicine, University of Ulm, Robert-Koch-Straβe 8 89081, Ulm, GermanyInfection and Immunity Group, School of Life Sciences, University of Sussex, Brighton BN1 9QG, UKResearch Society of Lung and Chest Diseases Ltd, Berlin 13125, GermanyDepartment of Internal Medicine II, Section of Pulmonary Medicine, University of Ulm, Robert-Koch-Straβe 8 89081, Ulm, GermanyAs a noninvasive method, exhaled breath condensate (EBC) has gained importance to improve monitoring of lung diseases and to detect biomarkers. The aim of the study was to investigate, whether erythropoietin (EPO) is detectable in EBC. EBC was collected from 22 consecutive patients as well as from healthy individuals. Using a multiplex fluorescent bead immunoassay, we detected EPO in EBC, as well as tumour necrosis factor-α (TNF-α) in 13 out of 22 patients simultaneously (EPO 0.21 ± 0.03 in U/mL and TNF-α 34.6 ± 4.2 in pg/mL, mean ± SEM). No significant differences for EPO levels or correlation between EPO and TNF-α were found but TNF-α was significantly higher in patients with chronic obstructive pulmonary disease (COPD) than in non-COPD (obstructive sleep apnoea, OSA, and lung healthy patients). This is the first report of detection of EPO in EBC. Due to the small study size more data is needed to clarify the role of EPO in EBC.http://dx.doi.org/10.1155/MI/2006/18061
collection DOAJ
language English
format Article
sources DOAJ
author Christian Schumann
Kathy Triantafilou
Stefan Krueger
Vinzenz Hombach
Martha Triantafilou
Gunther Becher
Philipp M. Lepper
spellingShingle Christian Schumann
Kathy Triantafilou
Stefan Krueger
Vinzenz Hombach
Martha Triantafilou
Gunther Becher
Philipp M. Lepper
Detection of Erythropoietin in Exhaled Breath Condensate of Nonhypoxic Subjects Using a Multiplex Bead Array
Mediators of Inflammation
author_facet Christian Schumann
Kathy Triantafilou
Stefan Krueger
Vinzenz Hombach
Martha Triantafilou
Gunther Becher
Philipp M. Lepper
author_sort Christian Schumann
title Detection of Erythropoietin in Exhaled Breath Condensate of Nonhypoxic Subjects Using a Multiplex Bead Array
title_short Detection of Erythropoietin in Exhaled Breath Condensate of Nonhypoxic Subjects Using a Multiplex Bead Array
title_full Detection of Erythropoietin in Exhaled Breath Condensate of Nonhypoxic Subjects Using a Multiplex Bead Array
title_fullStr Detection of Erythropoietin in Exhaled Breath Condensate of Nonhypoxic Subjects Using a Multiplex Bead Array
title_full_unstemmed Detection of Erythropoietin in Exhaled Breath Condensate of Nonhypoxic Subjects Using a Multiplex Bead Array
title_sort detection of erythropoietin in exhaled breath condensate of nonhypoxic subjects using a multiplex bead array
publisher Hindawi Limited
series Mediators of Inflammation
issn 0962-9351
1466-1861
publishDate 2006-01-01
description As a noninvasive method, exhaled breath condensate (EBC) has gained importance to improve monitoring of lung diseases and to detect biomarkers. The aim of the study was to investigate, whether erythropoietin (EPO) is detectable in EBC. EBC was collected from 22 consecutive patients as well as from healthy individuals. Using a multiplex fluorescent bead immunoassay, we detected EPO in EBC, as well as tumour necrosis factor-α (TNF-α) in 13 out of 22 patients simultaneously (EPO 0.21 ± 0.03 in U/mL and TNF-α 34.6 ± 4.2 in pg/mL, mean ± SEM). No significant differences for EPO levels or correlation between EPO and TNF-α were found but TNF-α was significantly higher in patients with chronic obstructive pulmonary disease (COPD) than in non-COPD (obstructive sleep apnoea, OSA, and lung healthy patients). This is the first report of detection of EPO in EBC. Due to the small study size more data is needed to clarify the role of EPO in EBC.
url http://dx.doi.org/10.1155/MI/2006/18061
work_keys_str_mv AT christianschumann detectionoferythropoietininexhaledbreathcondensateofnonhypoxicsubjectsusingamultiplexbeadarray
AT kathytriantafilou detectionoferythropoietininexhaledbreathcondensateofnonhypoxicsubjectsusingamultiplexbeadarray
AT stefankrueger detectionoferythropoietininexhaledbreathcondensateofnonhypoxicsubjectsusingamultiplexbeadarray
AT vinzenzhombach detectionoferythropoietininexhaledbreathcondensateofnonhypoxicsubjectsusingamultiplexbeadarray
AT marthatriantafilou detectionoferythropoietininexhaledbreathcondensateofnonhypoxicsubjectsusingamultiplexbeadarray
AT guntherbecher detectionoferythropoietininexhaledbreathcondensateofnonhypoxicsubjectsusingamultiplexbeadarray
AT philippmlepper detectionoferythropoietininexhaledbreathcondensateofnonhypoxicsubjectsusingamultiplexbeadarray
_version_ 1725195725846872064