Precision of Digital Volume Correlation Approaches for Strain Analysis in Bone Imaged with Micro-Computed Tomography at Different Dimensional Levels

Accurate measurement of local strain in heterogeneous and anisotropic bone tissue is fundamental to understand the pathophysiology of musculoskeletal diseases, to evaluate the effect of interventions from preclinical studies, and to optimize the design and delivery of biomaterials. Digital volume co...

Full description

Bibliographic Details
Main Authors: Enrico Dall’Ara, Marta Peña-Fernández, Marco Palanca, Mario Giorgi, Luca Cristofolini, Gianluca Tozzi
Format: Article
Language:English
Published: Frontiers Media S.A. 2017-11-01
Series:Frontiers in Materials
Subjects:
Online Access:http://journal.frontiersin.org/article/10.3389/fmats.2017.00031/full
id doaj-d06da972134b43d99a9da1287b338ebc
record_format Article
spelling doaj-d06da972134b43d99a9da1287b338ebc2020-11-25T00:13:04ZengFrontiers Media S.A.Frontiers in Materials2296-80162017-11-01410.3389/fmats.2017.00031297063Precision of Digital Volume Correlation Approaches for Strain Analysis in Bone Imaged with Micro-Computed Tomography at Different Dimensional LevelsEnrico Dall’Ara0Marta Peña-Fernández1Marco Palanca2Mario Giorgi3Luca Cristofolini4Gianluca Tozzi5Department of Oncology and Metabolism and INSIGNEO Institute for In Silico Medicine, University of Sheffield, Sheffield, United KingdomZeiss Global Centre, School of Engineering, University of Portsmouth, Portsmouth, United KingdomSchool of Engineering and Architecture, Alma Mater Studiorum – Università di Bologna, Bologna, ItalyDepartment of Oncology and Metabolism and INSIGNEO Institute for In Silico Medicine, University of Sheffield, Sheffield, United KingdomSchool of Engineering and Architecture, Alma Mater Studiorum – Università di Bologna, Bologna, ItalyZeiss Global Centre, School of Engineering, University of Portsmouth, Portsmouth, United KingdomAccurate measurement of local strain in heterogeneous and anisotropic bone tissue is fundamental to understand the pathophysiology of musculoskeletal diseases, to evaluate the effect of interventions from preclinical studies, and to optimize the design and delivery of biomaterials. Digital volume correlation (DVC) can be used to measure the three-dimensional displacement and strain fields from micro-computed tomography (μCT) images of loaded specimens. However, this approach is affected by the quality of the input images, by the morphology and density of the tissue under investigation, by the correlation scheme, and by the operational parameters used in the computation. Therefore, for each application, the precision of the method should be evaluated. In this paper, we present the results collected from datasets analyzed in previous studies as well as new data from a recent experimental campaign for characterizing the relationship between the precision of two different DVC approaches and the spatial resolution of the outputs. Different bone structures scanned with laboratory source μCT or synchrotron light μCT (SRμCT) were processed in zero-strain tests to evaluate the precision of the DVC methods as a function of the subvolume size that ranged from 8 to 2,500 µm. The results confirmed that for every microstructure the precision of DVC improves for larger subvolume size, following power laws. However, for the first time, large differences in the precision of both local and global DVC approaches have been highlighted when SRμCT or in vivo μCT images were used instead of conventional ex vivo μCT. These findings suggest that in situ mechanical testing protocols applied in SRμCT facilities should be optimized to allow DVC analyses of localized strain measurements. Moreover, for in vivo μCT applications, DVC analyses should be performed only with relatively course spatial resolution for achieving a reasonable precision of the method. In conclusion, we have extensively shown that the precision of both tested DVC approaches is affected by different bone structures, different input image resolution, and different subvolume sizes. Before each specific application, DVC users should always apply a similar approach to find the best compromise between precision and spatial resolution of the measurements.http://journal.frontiersin.org/article/10.3389/fmats.2017.00031/fullbonestraindigital volume correlationdeformable registrationmicro-computed tomographyprecision
collection DOAJ
language English
format Article
sources DOAJ
author Enrico Dall’Ara
Marta Peña-Fernández
Marco Palanca
Mario Giorgi
Luca Cristofolini
Gianluca Tozzi
spellingShingle Enrico Dall’Ara
Marta Peña-Fernández
Marco Palanca
Mario Giorgi
Luca Cristofolini
Gianluca Tozzi
Precision of Digital Volume Correlation Approaches for Strain Analysis in Bone Imaged with Micro-Computed Tomography at Different Dimensional Levels
Frontiers in Materials
bone
strain
digital volume correlation
deformable registration
micro-computed tomography
precision
author_facet Enrico Dall’Ara
Marta Peña-Fernández
Marco Palanca
Mario Giorgi
Luca Cristofolini
Gianluca Tozzi
author_sort Enrico Dall’Ara
title Precision of Digital Volume Correlation Approaches for Strain Analysis in Bone Imaged with Micro-Computed Tomography at Different Dimensional Levels
title_short Precision of Digital Volume Correlation Approaches for Strain Analysis in Bone Imaged with Micro-Computed Tomography at Different Dimensional Levels
title_full Precision of Digital Volume Correlation Approaches for Strain Analysis in Bone Imaged with Micro-Computed Tomography at Different Dimensional Levels
title_fullStr Precision of Digital Volume Correlation Approaches for Strain Analysis in Bone Imaged with Micro-Computed Tomography at Different Dimensional Levels
title_full_unstemmed Precision of Digital Volume Correlation Approaches for Strain Analysis in Bone Imaged with Micro-Computed Tomography at Different Dimensional Levels
title_sort precision of digital volume correlation approaches for strain analysis in bone imaged with micro-computed tomography at different dimensional levels
publisher Frontiers Media S.A.
series Frontiers in Materials
issn 2296-8016
publishDate 2017-11-01
description Accurate measurement of local strain in heterogeneous and anisotropic bone tissue is fundamental to understand the pathophysiology of musculoskeletal diseases, to evaluate the effect of interventions from preclinical studies, and to optimize the design and delivery of biomaterials. Digital volume correlation (DVC) can be used to measure the three-dimensional displacement and strain fields from micro-computed tomography (μCT) images of loaded specimens. However, this approach is affected by the quality of the input images, by the morphology and density of the tissue under investigation, by the correlation scheme, and by the operational parameters used in the computation. Therefore, for each application, the precision of the method should be evaluated. In this paper, we present the results collected from datasets analyzed in previous studies as well as new data from a recent experimental campaign for characterizing the relationship between the precision of two different DVC approaches and the spatial resolution of the outputs. Different bone structures scanned with laboratory source μCT or synchrotron light μCT (SRμCT) were processed in zero-strain tests to evaluate the precision of the DVC methods as a function of the subvolume size that ranged from 8 to 2,500 µm. The results confirmed that for every microstructure the precision of DVC improves for larger subvolume size, following power laws. However, for the first time, large differences in the precision of both local and global DVC approaches have been highlighted when SRμCT or in vivo μCT images were used instead of conventional ex vivo μCT. These findings suggest that in situ mechanical testing protocols applied in SRμCT facilities should be optimized to allow DVC analyses of localized strain measurements. Moreover, for in vivo μCT applications, DVC analyses should be performed only with relatively course spatial resolution for achieving a reasonable precision of the method. In conclusion, we have extensively shown that the precision of both tested DVC approaches is affected by different bone structures, different input image resolution, and different subvolume sizes. Before each specific application, DVC users should always apply a similar approach to find the best compromise between precision and spatial resolution of the measurements.
topic bone
strain
digital volume correlation
deformable registration
micro-computed tomography
precision
url http://journal.frontiersin.org/article/10.3389/fmats.2017.00031/full
work_keys_str_mv AT enricodallara precisionofdigitalvolumecorrelationapproachesforstrainanalysisinboneimagedwithmicrocomputedtomographyatdifferentdimensionallevels
AT martapenafernandez precisionofdigitalvolumecorrelationapproachesforstrainanalysisinboneimagedwithmicrocomputedtomographyatdifferentdimensionallevels
AT marcopalanca precisionofdigitalvolumecorrelationapproachesforstrainanalysisinboneimagedwithmicrocomputedtomographyatdifferentdimensionallevels
AT mariogiorgi precisionofdigitalvolumecorrelationapproachesforstrainanalysisinboneimagedwithmicrocomputedtomographyatdifferentdimensionallevels
AT lucacristofolini precisionofdigitalvolumecorrelationapproachesforstrainanalysisinboneimagedwithmicrocomputedtomographyatdifferentdimensionallevels
AT gianlucatozzi precisionofdigitalvolumecorrelationapproachesforstrainanalysisinboneimagedwithmicrocomputedtomographyatdifferentdimensionallevels
_version_ 1725396646471139328